Preferred Language
Articles
/
_xc48pEBVTCNdQwCkpzT
Removal of Cadmium from Simulated Wastewaters Using a Fixed Bed Bio-electrochemical Reactor
...Show More Authors

In this research, the removal of cadmium (Cd) from simulated wastewater was investigated by using a fixed bed bio-electrochemical reactor. The effects of the main controlling factors on the performance of the removal process such as applied cell voltage, initial Cd concentration, pH of the catholyte, and the mesh number of the cathode were investigated. The results showed that the applied cell voltage had the main impact on the removal efficiency of cadmium where increasing the applied voltage led to higher removal efficiency. Meanwhile increasing the applied voltage was found to be given lower current efficiency and higher energy consumption.  No significant effect of initial Cd concentration on the removal efficiency of cadmium but increasing the initial concentration would be given higher current efficiency and lower energy consumption. The results established that using a pH value lower than three results in a sharp decrease in the removal efficiency as well as  using a pH value higher than seven results in decreasing the removal efficiency. Using a mesh number higher than 30 gave a lower removal efficiency. The best operating conditions were found to be an applied potential of 1.8 V, an initial Cd concentration of 125 ppm, and a pH of 7. Under these operating conditions with the using a stack of stainless with mesh number 30 as a packed bed cathode, a complete removal efficiency of Cd(100%)  was obtained at a current efficiency of 83.57% and energy consumption of 0.57 kWh/kg Cd.

Crossref
View Publication
Publication Date
Fri Jan 01 2021
Journal Name
Desalination And Water Treatment
Electrosorption of cadmium ions from the aqueous solution by a MnO2/carbon fiber composite electrode
...Show More Authors

The nanostructured MnO2 /carbon fiber (CF) composite electrode was prepared using the anodic electrodeposition process. The crystal structure and morphology of MnO2 particles were determined with X-ray diffraction and field-emission scanning electron microscopy. The electrosorptive properties of the prepared electrode were investigated in the removal of cadmium ions from aqueous solution, and the effect of pH, cell voltage, and ionic strength was optimized and modeled using the response surface methodology combined with Box–Behnken design. The results confirm that the optimum conditions to remove Cd(II) ions were: pH of 6.03, a voltage of 2.77 V, and NaCl concentration of 3 g/L. The experimental results showed a good fit for the Freundli

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Wed Dec 31 2014
Journal Name
Journal Of Electrochemical Science And Technology
Preparation and Characterization of Electrodeposited Cadmium and Lead thin Films from a Diluted Chloride Solution
...Show More Authors

View Publication
Scopus (2)
Scopus Clarivate Crossref
Publication Date
Wed Nov 27 2024
Journal Name
International Journal Of Integrated Engineering
Noise Modeling and Removal from Electrocardiogram Signals: A Study Using Wavelet Transform with Graphical User Interface
...Show More Authors

View Publication
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Nov 27 2024
Journal Name
International Journal Of Integrated Engineering
Noise Modeling and Removal from Electrocardiogram Signals: A Study Using Wavelet Transform with Graphical User Interface
...Show More Authors

The electrocardiogram (ECG) is the recording of the electrical potential of the heart versus time. The analysis of ECG signals has been widely used in cardiac pathology to detect heart disease. The ECGs are non-stationary signals which are often contaminated by different types of noises from different sources. In this study, simulated noise models were proposed for the power-line interference (PLI), electromyogram (EMG) noise, base line wander (BW), white Gaussian noise (WGN) and composite noise. For suppressing noises and extracting the efficient morphology of an ECG signal, various processing techniques have been recently proposed. In this paper, wavelet transform (WT) is performed for noisy ECG signals. The graphical user interface (GUI)

... Show More
View Publication
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon Sep 30 2002
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Modeling of a Sulfonation Reactor in a Detergent Factory
...Show More Authors

View Publication Preview PDF
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
Dynamic Behavior of Pb(II) and Cr(III) Biosorption onto Dead Anaerobic Biomass in Fixed-Bed Column, Single and Binary Systems
...Show More Authors

The biosorption of lead (II) and chromium (III) onto dead anaerobic biomass (DAB) in single and binary systems has been studied using fixed bed adsorber. A general rate multi- component model (GRM) has been utilized to predict the fixed bed breakthrough curves for single and dual- component system. This model considers both external and internal mass transfer resistances as well as axial dispersion with non-liner multi-component isotherm (Langmuir model). The effects of important parameters, such as flow rate, initial concentration and bed height on the behavior of breakthrough curves have been studied. The equilibrium isotherm model parameters such as maximum uptake capacities for lead (II) and chromium (III) were found to be 35.12 and

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Fri Apr 01 2016
Journal Name
Journal Of Engineering
Separation of Lead (Pb2+) and Cadmium (Cd2+) from Single and Binary Salt Aqueous Solutions Using Nanofiltration Membranes
...Show More Authors

The present work reports on the performance of three types of nanofiltration membranes in the removal of highly polluting and toxic lead (Pb2+) and cadmium (Cd2+) from single and binary salt aqueous solutions simulating real wastewaters. The effect of the operating variables (pH (5.5-6.5), types of NF membrane and initial ions concentration (10-250 ppm)) on the separation process and water flux was investigated. It was observed that the rejection efficiency increased with increasing pH of solution and decreasing the initial metal ions concentrations. While the flux decreased with increasing pH of solution and increasing initial metal ions concentrations. The maximum rejection of lead and cadmium ion

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
Nurse Scheduling Problem Using Hybrid Simulated Annealing Algorithm
...Show More Authors

Nurse scheduling problem is one of combinatorial optimization problems and it is one of NP-Hard problems which is difficult to be solved as optimal solution. In this paper, we had created an proposed algorithm which it is hybrid simulated annealing algorithm to solve nurse scheduling problem, developed the simulated annealing algorithm and Genetic algorithm. We can note that the proposed algorithm (Hybrid simulated Annealing Algorithm(GS-h)) is the best method among other methods which it is used in this paper because it satisfied minimum average of the total cost and maximum number of Solved , Best and Optimal problems. So we can note that the ratios of the optimal solution are 77% for the proposed algorithm(GS-h), 28.75% for Si

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jun 30 2021
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.: ELECTROCHEMICAL PREPARATION OF A MOLECULAR IMPRINTED POLYMER ELECTRODE FOR ESTEMATION OF ASPIRIN USING TWO DIFFERENT FUNCTIONAL MONOMERS.
...Show More Authors

For aspirin estimated, a molecularly imprinted polymer MIP-ASP electrodes were generated by electro-polymerization process, the electrodes were prepared by combining the template (aspirin) with (vinyl acetate (VA), 1-vinylimidizole (VIZ) as a functional monomer and N, N-methylene bisacrylamide (MBAA) as crosslinkers using benzoyl peroxide (BPO) as an initiator. The efficiency of the membrane electrodes was analyzed by differential pulse voltammetry (DPV). Four electrodes were synthesized using two different plasticizers, di-butyl sebacate (DBS), di-octyl phthalate (DOP) in PVC matrix. Scanning electron microscopy (SEM) was used to describe the generated MIP, studying the electrodes properties, the slope, detection limit, and life

... Show More
View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
International Journal Of Modern Trends In Engineering And Research
Quadtree Partitioning Scheme using Fixed Predictor Base
...Show More Authors