Preferred Language
Articles
/
_uZ2k5wBmraWrQ4dpUsr
Solubility and Dissolution Rate Enhancement of Bilastine by Solid Dispersion Technique
...Show More Authors

Bilastine (BLS) is non-sedating new-brand H1 antihistamine that has selective peripheral effects, the drug has a problem of an insufficient aqueous solubility and accordingly low dissolution rate, and low bioavailability. Solid dispersion (SD) is one of the most effective techniques for improving the solubility and the dissolution rate of poorly soluble drugs by the dispersion of drug within an inert hydrophilic carrier.   The aim of this study is to increase the solubility and dissolution rate of the BLS using SD technique. Twenty-nine BLS SD formulas were prepared using different carrier polymers include Pluronic 407 (Poloxamer407), Poloxamer188, Urea, Polyethylene glycol 6000 (PEG6000) and Polyvinylpyrrolidone (PVP K30) and employing two different preparation methods (solvent evaporation and kneading method) at different drug: polymer ratios (1:1 ,1:3,1:5,1:10,1:15). The prepared SD formulas were evaluated for their percent yield, drug content, aqueous solubility, dissolution rate, PXRD, and FTIR. The SD technique successfully improved the solubility and dissolution rate of BLS. The improvement was largely dependent on the polymer type and drug: polymer ratio. The solubility improvement using different polymers was in the following order: PVP K30> PLX188> PEG6000> Urea> PLX407. The solid dispersion formula that showed the best outcomes in terms of dissolution improvement was prepared using the solvent evaporation technique employing PVP K30 at ratio of drug: polymer of 1:15. The optimized formula showed 10.2 folds increment in the solubility compared to pure BLS. It can be concluded that the SD technique can successfully improve the solubility and dissolution rate by solvent evaporation method with careful selection of the carrier polymer and drug: polymer ratio.

Scopus Crossref
View Publication
Publication Date
Sun Jun 04 2017
Journal Name
Baghdad Science Journal
Improvement of the technique for the solution method of Gauss Seidel
...Show More Authors

In this paper, a new approach was suggested to the method of Gauss Seidel through the controlling of equations installation before the beginning of the method in the traditional way. New structure of equations occur after the diagnosis of the variable that causes the fluctuation and the slow extract of the results, then eradicating this variable. This procedure leads to a higher accuracy and less number of steps than the old method. By using the this proposed method, there will be a possibility of solving many of divergent values equations which cannot be solved by the old style.

View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Apr 25 2012
Journal Name
The Nineteenth Scientific Conference The College Of Education \al-mustansiriyah University
Solution of Ordinary BVP's of Eighth Order Using Osculatory Interpolation Technique
...Show More Authors

The aim of this paper is to present method for solving ordinary differential equations of eighth order with two point boundary conditions. We propose two-point osculatory interpolation to construct polynomial solution.

View Publication
Publication Date
Thu Dec 01 2022
Journal Name
Journal Of Energy Storage
A hybrid solidification enhancement in a latent-heat storage system with nanoparticles, porous foam, and fin-aided foam strips
...Show More Authors

Scopus (32)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Swinburne University Of Technology
Numerical Modeling of Flow through Foam Nodes in the Presence of Solid Particles for Foams within the Dry Limit and for Foams that are Approaching the Wet Limit
...Show More Authors

View Publication Preview PDF
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Optics
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed Apr 19 2017
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences
Separation and determination of poly aromatic hydrocarbons in vegetables samples in Baghdad city using HPLC Technique
...Show More Authors

The Reversed Phase High Performance Liquid Chromatography (RP-HPLC) has been used for the separation of Poly aromatic hydrocarbons(PAHs) by using column Reprosil 100 C 18 which was found to be a suitable one for this purpose. The result showed that using mobile phase of (Acetonitrile-water) Reversed Phase HPLC , flow rate of (1.2 ml/min) , column temperature (30CËš) and wave length of (254nm), give a complete separation with a good resolution . The total separation time was less than 20 min. The result of the study showed that the vegetables of Baghdad city were polluted by poly aromatic hydrocarbons(PAHs) in different places where samples taken because of drainage of the heavy water ,industrial trash and trash of oil colanders. -

... Show More
Publication Date
Wed Sep 27 2023
Journal Name
Journal Of Optics
Studying the responsivity and detectivity of GO/PSi/n-Si photo detector via drop casting technique
...Show More Authors

View Publication
Scopus (6)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Sun Mar 01 2020
Journal Name
Plant Archives
Thermodynamic and kinetic analysis of Basic green-4 dye Removal from aqueous solutions using adsorption technique
...Show More Authors

In this work, a local sunflower husk (SFH) was used as a natural surface for removing Basic Green-4 (BG4) dye, as a watersoluble pollutant. The effect of initial concentration, contact time, the mass of surface of the dye with the SFH as well as the medium temperature was studied. The application of Langmuir, Freundlich isotherms on the collected data of the adsorption process found to harmonize to Freundlich equation more than that of Langmuir. However, the adsorbed mass of BG4 dye showed a direct increase with the increase of SFH mass and equilibrium was achieved within a 60min window. The interaction of BG4 with SFH surface was spontaneous and exothermic. The empirical kinetic outcomes at ambient temperatures were applied to pseudo 1st a

... Show More
Preview PDF
Scopus
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection of 0.0

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (8)
Scopus Crossref
Publication Date
Fri Jun 16 2023
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Colorimetric Determination of Salbutamol Sulfate using Spectrophotometry-Continuous Flow Injection Technique in Pure and Pharmaceutical Forms
...Show More Authors

Simple, precise and economic batch and flow injection analysis (FIA)-spectrophotometric methods have been established for simultaneous determination of salbutamol sulfate (SLB) in bulk powder and pharmaceutical forms. Both methods based on diazotization coupling reaction of SLB with another drug compound (sulfadimidine) as a safe and green diazotization agent in alkaline medium. At 444 nm, the maximum absorption of the orange azo-dye product was observed. A thorough investigation of all chemical and physical factors was conducted for batch and FIA procedures to achieve high sensitivity. Under the optimized experimental variables, SLB obeys Beer’s law in the concentration range of 0.25-4 and 10-100 μg/mL with limits of detection o

... Show More
Scopus (14)
Crossref (8)
Scopus Crossref