Bilastine (BLS) is non-sedating new-brand H1 antihistamine that has selective peripheral effects, the drug has a problem of an insufficient aqueous solubility and accordingly low dissolution rate, and low bioavailability. Solid dispersion (SD) is one of the most effective techniques for improving the solubility and the dissolution rate of poorly soluble drugs by the dispersion of drug within an inert hydrophilic carrier. The aim of this study is to increase the solubility and dissolution rate of the BLS using SD technique. Twenty-nine BLS SD formulas were prepared using different carrier polymers include Pluronic 407 (Poloxamer407), Poloxamer188, Urea, Polyethylene glycol 6000 (PEG6000) and Polyvinylpyrrolidone (PVP K30) and employing two different preparation methods (solvent evaporation and kneading method) at different drug: polymer ratios (1:1 ,1:3,1:5,1:10,1:15). The prepared SD formulas were evaluated for their percent yield, drug content, aqueous solubility, dissolution rate, PXRD, and FTIR. The SD technique successfully improved the solubility and dissolution rate of BLS. The improvement was largely dependent on the polymer type and drug: polymer ratio. The solubility improvement using different polymers was in the following order: PVP K30> PLX188> PEG6000> Urea> PLX407. The solid dispersion formula that showed the best outcomes in terms of dissolution improvement was prepared using the solvent evaporation technique employing PVP K30 at ratio of drug: polymer of 1:15. The optimized formula showed 10.2 folds increment in the solubility compared to pure BLS. It can be concluded that the SD technique can successfully improve the solubility and dissolution rate by solvent evaporation method with careful selection of the carrier polymer and drug: polymer ratio.
A solid Phase Extraction (SPE) cartridges followed by HPLC-UV method is described for the simultaneous quantitative determination of benzidine (BZ) and its substituted 3, 3’-dichlorobenzidine (DCB) and 3, 3’-Dimethylbenzidine (DMB). The Benzidines were separated by liquid chromatography using a C-18 column with UV detector at wave length of 280nm. The mode of Flow was isocratic. The mobile phase was consisted of 75:25 methanol: water, column temperature 50C°, and Flow Rate 1.8ml/min. Calibration curves were linear (R2 = 0.9979-0.9995). LOD (26.36-33.67) µg/L, LOQ (109.98-186.11) µg/L, the Robustness (2.99-4.35), Ruggedness (2.93-3.65).Conditions of extraction by (SPE) cartridges were optimized, the resin used is Octadecyl silica (ODS
... Show MoreAn analytical method and a two-dimensional finite element model for treating the problem of laser heating and melting has been applied to aluminum 2519T87and stainless steel 304. The time needed to melt and vaporize and the effects of laser power density on the melt depth for two metals are also obtained. In addition, the depth profile and time evolution of the temperature before melting and after melting are given, in which a discontinuity in the temperature gradient is obviously observed due to the latent heat of fusion and the increment in thermal conductivity in solid phase. The analytical results that induced by laser irradiation is in good agreement with numerical results.
Background: Although various imaging modalities are available for evaluating suspicious breast lesions, ultrasound-based Shear-Wave Elastography (SWE) is an advanced, non-invasive technique complementary to grayscale sonography. This technique evaluates the elasticity of a specific tissue by applying sonic pressure to that tissue.
Objective: The aim is to assess the role of SWE in evaluating solid breast masses in correlation to histopathological study results.
Subjects and Methods: This prospective study was done in a tertiary care teaching hospital from September 2019 to August 2020. A study population of 50 women aged 18 years or above with an
... Show MoreA steganography hides information within other information, such as file, message, picture, or video. A cryptography is the science of converting the information from a readable form to an unreadable form for unauthorized person. The main problem in the stenographic system is embedding in cover-data without providing information that would facilitate its removal. In this research, a method for embedding data into images is suggested which employs least significant bit Steganography (LSB) and ciphering (RSA algorithm) to protect the data. System security will be enhanced by this collaboration between steganography and cryptography.
This article aim to estimate the Return Stock Rate of the private banking sector, with two banks, by adopting a Partial Linear Model based on the Arbitrage Pricing Model (APT) theory, using Wavelet and Kernel Smoothers. The results have proved that the wavelet method is the best. Also, the results of the market portfolio impact and inflation rate have proved an adversely effectiveness on the rate of return, and direct impact of the money supply.
يهدف البحث الحالي إلى الاستفادة من القهوة المستهلكة , كمادة وسيطة حيث تعد القهوة المستهلكة من المخلفات المضرة للبيئة الاستخراج الكافيين الطبيعي والذي يعد مادة ذات نشاط حيوي واهمية, وتحديد العوامل الفعالة في كفاءة عملية الاستخلاص من حيث تركيز الكافيين. تضمنت المتغيرات الرئيسية المدروسة وقت الاستخلاص 0-150 دقيقة ، ودرجة الحرارة 25-55 درجة مئوية ، وسرعة الخلط 180-450 دورة في الدقيقة ، ودرجة الحموضة العالق
... Show MoreOral fast dissolving films (OFDFs) are the most innovative oral solid pharmaceutical dosage form, especially for elderly and pediatric patients who may have dysphagia. Bilastine (BLA), is a second – generation antihistamine used to manage allergy symptoms; it is very slightly soluble in water. The main objective of this research was to enhance the solubility and dissolution rate of BLA by complexation technique. Ternary complex of BLA: methyl β- cyclodextrin (M-β-CD): soluplus® 5% w/w was prepared via solvent evaporation technique as a trial to enhance its solubility to be prepared as OFDF by incorporated into aqueous polymeric solution. Seven formulas of OFDFs were prepared using the solvent casting method using
... Show MoreHeat transfer around a flat plate fin integrated with piezoelectric actuator used as oscillated fin in laminar flow has been studied experimentally utilizing thermal image camera. This study is performed
for fixed and oscillated single and triple fins. Different substrate-fin models have been tested, using fins of (35mm and 50mm) height, two sets of triple fins of (3mm and 6mm) spacing and three frequencies
applied to piezoelectric actuator (5, 30 and 50HZ). All tests are carried out for (0.5 m/s and 3m/s) in subsonic open type wind tunnel to evaluate temperature distribution, local and average Nusselt number (Nu) along the fin. It is observed, that the heat transfer enhancement with oscillation is significant compared to without o
The enhancement of heat exchanger performance was investigated using dimpled tubes tested at different Reynolds numbers, in the present work four types of dimpled tubes with a specified configuration manufactured, tested and then compared performance with the smooth tube and other passive techniques performance. Two dimpled arrangements along the tube were investigated, these are inline and staggered at constant pitch ratio X/d=4, the test results showed that Nusselts number (heat transfer) of the staggered array is higher than the inline array by 13%. The effect of different depths of the dimple (14.5 mm and 18.5 mm) has been also investigated; a tube with large dimple diameter enhanced the Nusselts number by about 25% for the ran
... Show MoreBilastine (BL) is a novel non-sedating second-generation antihistamine, and its bioavailability is about 60%. Objective: To compare the bioavailability of prepared oral self-nanoemulsions of BL (BL-SNE) with that of pure BL and marketed tablets. Methods: Four groups of Wistar rats were used in this study, each with six rats weighing between 200 and 250 g. They were treated orally using a a gavage tube. The groups were fed either with conventional tablets ("Alerbix®") after being ground and dispersed with deionized water (DIW), treated with BL-SNE or fed with pure BL powder suspension. The fourth group did not receive any medication. The concentration of BL in the rat’s plasma was measured using HPLC. We used Trandolapril as an an interna
... Show More