One hundred isolates of Pseudomonas aeruginosa were obtained from patients admitted to Baghdad hospitals, Iraq during the period between May 2018 until July 2018. These isolates were distributed as 15 isolates from blood, 25 isolates from urinary tract infections, 10 isolates from sputum, 12 isolates from wounds, 15 isolates from ear infections, 15 isolates from bronchial wash of patients suffering from respiratory tract infections in addition to 8 isolates from cystic fibrosis patients. The isolates were initially identified by culturing on MacConkey agar, blood agar and P. aeruginosa agar then diagnosed by performing some morphological and biochemical tests. The second diagnosis was done by API 20E system followed by Vitek 2 compact system. Antibiotic sensitivity test was carried out towards 15 antibiotics using disc diffusion method (Kirby–Bauer method). The results of sensitivity test showed that P. aeruginosa isolates possessed high resistance towards most antibiotics under study, the most antibiotic resistance was towards Gentamicin 87 (87%), whereas the lowest resistance was towards Imipenem 10 (10%). In this study, two types of methods were used in the detection of biofilm formation: the first one was Congo red agar method and the second one was microtiter plate method. In the first method, results showed that biofilm formed by 57/100 (57%) according to black color production on media, whereas in the second method was 69/100 (69%) produce strong adherence according to OD in ELISA reader. Genotypic detection of many virulence factors related to P. aeruginosa was performed using conventional PCR. These included: gene coded for exoenzyme S (exoS), exoenzyme U (exoU), exotoxin A (toxA), two phospholipases C encoded by (plcH) and (plcN), alginate (algD), (lasB), rpsl, proteaseIV, and Neuraminidase (nan1). The results revealed that the most frequent gene was exoS as it was detected in 87/100 (87%) isolates, whereas the least frequent gene was nan1 as it was detected in only 9/100 (9%). The frequency of detection of other genes were as follows: toxAi in 55/100 (55%); plcH in 45/100 (45%); exoU in 42/100 (42%); plcN in 33/100 (33%); proteaseIV in 31/100 (31%), algD in 29/100 (29%); lasB in 28/100 (28%), and rpsl in 25/100 (25%). Phylogenetic analysis by Enterobacterial Repetitive Intergenic Consensus (ERIC-PCR), ERIC-DNA Fingerprinting revealed the diversity of all isolates in Baghdad by using Dice coefficient and the unweighted pair group method with arthmetic average (group method) of phylogenetic analysis. The percentage level of similarity clearly showed that the isolates examined by species were divided into two distinct cluster numbers, in addition to three single isolates (clone), that clustered at a similarity level of (93%). According to the statistical analysis, it was found that the correlation coefficient of ERIC genotyping method with virulence genes in this study and antibiotics sensitivity test was significant at P < 0.05 (two-tailed), whereas correlation with biofilm was not significant
This search include the synthesis of some new 1,3-oxazepine derivatives have been prepared, starting from reaction of L-ascorbic acid with dry acetone in presence of dry hydrogen chloride afforded the acetal (I). Treatment of the latter with p-nitrobenzoyl chloride in pyridine yielded the ester (II) which was dissolved in (65%) acetic acid in absolute ethanol yielded the glycol (III). The reaction of the glycol (III) with sodium periodate in distilled water at room temperature produced the aldehyde (IV). The compound (V) [4-(1,3-dioxoisoindolin-2-yl)benzoic acid] was synthesized by reaction p-aminobenzoic acid and phthalic anhydride in presence of (gla. CH3COOH). Reaction of compound (V) with thionyl chloride produced [4-(1,3-dioxoisoindoli
... Show MoreWhen the depth of stressed soil is rather small, Plate Load Test (PLT) becomes the most efficient test to estimate the soil properties for design purposes. Among these properties, modulus of subgrade reaction is the most important one that usually employed in roads and concrete pavement design. Two methods are available to perform PLT: static and dynamic methods. Static PLT is usually adopted due to its simplicity and time saving to be performs in comparison with cyclic (dynamic) method. The two methods are described in ASTM standard.
In this paper the effect of the test method used in PLT in estimation of some mechanical soil properties was distinguished via a series of both test methods applied in a same site. The comparison of
... Show MoreIn the present work, different thicknesses of CdS film were prepared by chemical bath deposition. Z-Scan technique was used to study the nonlinear refractive index and nonlinear absorption coefficients. Linear optical testing were done such as transmission test, and thickness of films were done by the interference fringes (Michelson interferometer). Z-scan experiment was performed at 650nm using CW diode laser and at 532nm wavelength. The results show the effect of self-focusing and defocusing that corresponds with nonlinear refraction n2. The effect of two-photon absorption was also studied, which correspond to the nonlinear absorption coefficient B.
The amount of protein in the serum depends on the balance between the rate of its synthesis, and that of its catabolism or loss. Abnormal metabolism may result from nutritional deficiency, enzyme deficiency, abnormal secretion of hormones, or the actions of drugs and toxins. Renal cancer is the third most common malignancy of the genitourinary system, and accounts for 3% of adult malignancies globally. Total serum proteins were measured in malignant kidney tumor, benign kidney tumors, and non tumoral kidney diseases patient groups, as well as in healthy individuals. A significant decrease (p< 0.001) of total serum protein levels in patients with malignant kidney tumors when compared with those of benign tumors, non tumoral diseases, and hea
... Show MoreThe current research illustrates experimentally the effect of series and parallel connection (Z-I Configurations) of flat plate water solar collectors array on the thermal performance of closed loop solar heating system. The study includes the effect of changing the water flow rate on the thermal efficiency. The results show that, the collector's efficiency in series connection is higher than the parallel connection within flow rate level less than (100) ℓ/hr. Moreover, the collector efficiency in parallel connection of (I-Configurations) is more than the (Z- Configurations) with increasing the water flow rate .The maximum daily efficiency for parallel (I-Configurations) and (Z- Configurations) are (55%) and (51%) at w
... Show MoreMost reinforced concrete (RC) structures are constructed with square/rectangular columns. The cross-section size of these types of columns is much larger than the thickness of their partitions. Therefore, parts of these columns are protruded out of the partitions. The emergence of columns edges out of the walls has some disadvantages. This limitation is difficult to be overcome with square or rectangular columns. To solve this problem, new types of RC columns called specially shaped reinforced concrete (SSRC) columns have been used as hidden columns. Besides, the use of SSRC columns provides many structural and architectural advantages as compared with rectangular columns. Therefore, this study was conducted to explain the structura
... Show More