Objective: To compare two insertion techniques of intramedullary interlocking nails (medial parapatellar versus intrapatellar insertion) in patients with tibial fractures. Methodology: This study was performed at Al-Kindy Teaching Hospital from August 2020 until March 2022. All 32 patients with tibial fractures (29 males and 3 females) were included for tibial closed nail fixation and then followed up for 6 months. We categorized these patients into two groups; Group A (16 patients), those treated by medial parapatellar insertion of an interlocking nail, and Group B (16 patients) with transpatellar tibial nail insertion. All patients were treated by the same surgical team. Results: The range of movement in two weeks (from extension to flexion) was up to 30°. At the end of the follow-up period, all patients in Group A had functional flexion greater than 90°, whereas three patients in Group B had limited flexion that necessitated scheduled physical therapy. Regarding the functional outcome, in group A patients and in group B patients, the mean International Knee Documentation Committee score demonstrated a better outcome in patients with medial parapatellar insertion than those in group B. According to the visual analysis score, the transpatellar insertion demonstrated more discomfort than that in the paramedial insertion group, both clinically and statistically. Conclusion: Medial entry point in intra medullary tibial nailing had less anterior knee pain in post-operative follow up.
ABSTRACT Background: One of the major problems of all ceramic restorations is their probable fracture against the occlusal forces. The objective of this in vitro study was to evaluate the effect of two gingival finishing lines (90°shoulder and deep chamfer) on the fracture resistance of full contour CAD/CAM and heat press all-ceramic crowns. Materials and Methods: Thirty two maxillary first premolars were prepared to receive full contour CAD/CAM (zolid) and heat press (Cergo Kiss) ceramic crowns using a special paralleling device (Parallel-A-Prep). The teeth were divided into four groups according to the type of finishing line prepared. Each crown was cemented to its corresponding tooth using self-etch, self-adhesive dual cure resin ceme
... Show More
Comparative literature is one of the important research topics in finding new relations and results that other types of studies do not allow.
The present research is a comparative study between two contemporary poets : Al-Sayyab and Prévert. The reason for accomplishing this research is Al-Sayyab’s reading for the western literature. Moreover, the study sheds a light on translational criticism.
It tackles the lives of the two writers and their points of similarities and differences. Prévert and Al-Sayyab’s are two modern poets. The first employed his daily routines to express reality, specially the events of the two world wars. The second’s pain, on the other hand, was the starting point to express others’ suffe
... Show MoreThis study was done to find a cheap, available and ecofriendly materials that can remove eosin y dye from aqueous solutions by adsorption in this study, two adsorbent materials were used, the shells of fresh water clam (Cabicula fluminea) and walnut shells. To make a comparison between the two adsorbents, five experiments were conducted. First, the effects of the contact time, here the nut shell removed the dye quickly, while the C. flumina need more contact time to remove the dye. Second, the effects of adsorbent weight were examined. The nut shell was very promising and for all used adsorbent weight, the R% ranged from 94.87 to 99.29. However C. fluminea was less effective in removing the dye with R% ranged from 47.59 to 55.39. The thi
... Show MoreBackground: The aim of this in vitro study was to evaluate and compare the microleakage between Vertise Flow T M composite material and other conventional (Filtek Z250, riva light cure and SDR) composite materials when restoring CII mesial box only cavity at gingival margin through die penetration test Materials and methods: Forty maxillary first premolars were prepared with class II box design only cavities. Samples were divided into four groups of ten teeth according to material used: group I (FiltekZ250 only). Group II (SDR+FiltekZ250). Group III (Vertise Flow +FiltekZ250). Group IV (Riva light cure+ FiltekZ250). After 24 hrs. immersion in 2% in methylene blue, samples were sectioned and micro leakage was estimated. Results: None of the
... Show MoreBootstrap is one of an important re-sampling technique which has given the attention of researches recently. The presence of outliers in the original data set may cause serious problem to the classical bootstrap when the percentage of outliers are higher than the original one. Many methods are proposed to overcome this problem such Dynamic Robust Bootstrap for LTS (DRBLTS) and Weighted Bootstrap with Probability (WBP). This paper try to show the accuracy of parameters estimation by comparison the results of both methods. The bias , MSE and RMSE are considered. The criterion of the accuracy is based on the RMSE value since the method that provide us RMSE value smaller than other is con
... Show MoreSince the Internet has been more widely used and more people have access to multimedia content, copyright hacking, and piracy have risen. By the use of watermarking techniques, security, asset protection, and authentication have all been made possible. In this paper, a comparison between fragile and robust watermarking techniques has been presented to benefit them in recent studies to increase the level of security of critical media. A new technique has been suggested when adding an embedded value (129) to each pixel of the cover image and representing it as a key to thwart the attacker, increase security, rise imperceptibility, and make the system faster in detecting the tamper from unauthorized users. Using the two watermarking ty
... Show MoreBackground: This study compared in vitro the marginal adaptation of three different, low shrink, direct posterior composites Filtekâ„¢ P60 (packable composite), Filtekâ„¢ P90 (Silorane-based composite) and Sonic fillâ„¢ (nanohybrid composite) at three different composite/enamel interface regions (occlusal, proximal and gingival regions) of a standardized Class II MO cavity after thermal changes and mechanical load cycling by scanning electron microscopy. Materials and methods:Thirty six sound human maxillary first premolars of approximately comparable sizes were divided into three main groups of (12 teeth) in each according to the type of restorative material that was used: group (A) the teeth were restored with Filtekâ„¢ P6
... Show MoreResin-modified glass ionomer cement tends to shrink due to polymerization of the resin component. Additionally, they are more prone to syneresis and imbibition during the setting process. This