Preferred Language
Articles
/
_Xi6K6EBuRolNscLxfgs
Analysis of radio-opacity, surface roughness, and wettability of calcium carbonate nanoparticle-reinforced three-dimensional printed acrylic resin
...Show More Authors
Background

Additive manufacturing (3D-printed) technology is a major advancement in prosthodontics, offering efficiency, cost-effectiveness, and the production of high-quality prostheses. Nanoparticles have been included in three-dimensional (3D) printed denture bases to enhance their physico-mechanical and biological characteristics. This work aims to examine the influences of adding calcium carbonate nanoparticles to 3D-printed denture base resins on their radio-opacity, wettability, and surface roughness.

Material and method

Ninety specimens were split into three groups: two modified groups (1.5 and 2 weight percent CaCO 3 NPs) and one control group (unmodified group). Three identical subgroups for the radiopacity test, surface roughness, and wettability test were formed from each concentration (n = 10). Additionally, the chemical composition of the 3D resin was also investigated using Fourier transform infrared spectroscopy (FTIR) to see if the addition of calcium carbonate nanoparticles changed it, and the surface topography of 3D-printed acrylic specimens was compared using atomic force microscopy (AFM).

Result

Results revealed a significant improvement in the radio-opacity, wettability, and surface roughness (p < 0.05) after adding calcium carbonate nanoparticles to the 3D-printed denture base resin.

Conclusion

The specimens with 2% wt. of CaCO 3 NPs showed the greatest increase in radio-opacity. While specimens containing 1.5% wt. CaCO 3 NPs showed lower surface roughness and higher wettability.

Scopus Crossref
View Publication
Publication Date
Thu Mar 01 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Addition of Combination of Plasma Treated Polyester and Polyamide Fibers on Surface Roughness and Some Mechanical Properties of Heat Cured Acrylic Resin
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Thu Mar 15 2018
Journal Name
Journal Of Baghdad College Of Dentistry
The Effect of Addition of Combination of Plasma Treated Polyester and Polyamide Fibers on Surface Roughness and Some Mechanical Properties of Heat Cured Acrylic Resin
...Show More Authors

Background: Poly (methyl methacrylate) has several disadvantages (poor mechanical properties) like impact and transverse strength. In order to overcome these disadvantages, several methods were used to strengthen the acrylic resin by using different fibers or fillers. This study was conducted to evaluate the effect of Plasma treatment of the fiber on mechanical properties Poly (methyl methacrylate) denture base material. Materials and methods: Specimens were prepared from poly methyl metha acrylic (PMMA) divided according to present of fiber into 4 groups (first group without fiber as control group, second group with Plasma treated polyester fibers, third group with Plasma treated polyamide fibers and fourth group Plasma treated combination

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Indian Journal Of Forensic Medicine & Toxicology
Effect of Thermocycling on Surface Roughness and Shear Bond Strength of Acrylic Soft Liner to the Surface of Thermoplastic Acrylic Treated with Ethyl Acetate
...Show More Authors

Objective: To enhance bonding strength between thermoplastic denture base and acrylic soft liner through ethyl acetate surface treatment. Materials and Methods: Modifications of thermoplastic acrylic denture base surface were investigated with SEM. FTIR was used to detect whether there was a chemical bond between thermoplastic acrylic and the organic solvent. A total of 80 samples were prepared and divided into 20 samples for the surface roughness test and 60 samples for the shear bond strength test. Failure type was assessed visually. Results: Shear bond strength and surface roughness values of un treated samples were lower in comparison to surface treated groups; the greatest post thermocycling bond strength value was recorded for the sam

... Show More
Preview PDF
Publication Date
Mon Jun 15 2020
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of plasma treatment on some surface properties of acrylic resin polymer
...Show More Authors

Background: Polymer surfaces usually present problems in bonding and finishing due to their low hydrophilicity. The aim of this study is to investigate the effect of plasma treatment with the use of two types of gases (oxygen and argon) on surface roughness, and chemical surface properties of acrylic resin denture base polymer material. Materials and Methods: Three heat cured acrylic resin specimens of (2*8*30 mm) dimensions were prepared for each test carried out in this study. Two tests were conducted, surface roughness test and chemical surface analysis test. Results: Application of plasma treatment increased surface roughness for both oxygen and argon plasma treated acrylic resin specimen groups compared with control untreated group,

... Show More
View Publication Preview PDF
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Mon Oct 12 2026
Journal Name
Journal Of Baghdad College Of Dentistry
Estimation of the linear dimensional changes of autoclave cured acrylic resin with multiple palatal depths and investment materials
...Show More Authors

Background: Dimensional changes of acrylic denture bases after polymerization results in need for further adjustments or even ends with technical failure of the finished dentures. The purpose of this study was to estimate the linear dimensional changes for different palatal depths when using multiple investment materials and polymerization techniques. Materials and methods: Ninety upper complete denture bases were constructed for this study. They were divided into two main groups according to the polymerization methods: conventional water bath and experimental autoclave (short and long cycles). Each main group was further subdivided into three subgroups according to the palatal depth (shallow, medium and deep). Furthermore, for each palatal

... Show More
View Publication Preview PDF
Publication Date
Tue Mar 13 2018
Journal Name
Mustansiria Dental Journal
Dimensional stability of heat-activated acrylic resin at different time intervals by different flask cooling methods
...Show More Authors

This study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an

... Show More
Preview PDF
Publication Date
Mon Jun 16 2025
Journal Name
Progress In Additive Manufacturing
Parametric optimization of layer thickness, speed, and high acceleration on surface roughness, productivity, and quality of 3D printed PLA objects
...Show More Authors

Despite the broad approbation of additive manufacturing technologies over diverse industries, printed parts’ performance, quality, and related build time are still greatly influenced by printing parameters. These parameters majorly affect mechanical strength, surface finish, dimensional accuracy, and overall production time of the printed part. Customized 3D printing layer thickness, speed, and acceleration are crucial parameters that affect the speedy printing process and final product quality. The current work considers layer thickness in addition to speed and high acceleration values effect on the surface quality, surface roughness and productivity time of 3D printed Polylactic Acid (PLA). The experimental methodology implemented withi

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Mon Oct 12 2026
Journal Name
Journal Of Baghdad College Of Dentistry
The Effects of Different Investment Materials on Dimensional Accuracy and Surface Roughness of Thermosens Maxillary Complete Dentures
...Show More Authors

Background: Limited data are available on the dimensional stability and surface roughness of ThermoSens, which is a material used in denture processing. This study aimed to measure the vertical teeth changes and surface roughness of ThermoSens dentures prepared using three different investment materials. Materials and methods: For the dimensional changes test, 30 complete maxillary dentures were prepared using different investment methods: group I, dental stone; group II, silicone putty; and group III, a mixture of dental stone and plaster (ratio, 1:1; n = 10 for each group). Four screws were attached to the dentures: two were attached to the buccal surface of the canine and first molar, and the other two were attached in the flange areas o

... Show More
View Publication Preview PDF
Publication Date
Thu Jul 25 2024
Journal Name
Metals
The Effects of Three Antibacterial Nanoparticle Coatings on the Surface Characteristics of Stainless Steel
...Show More Authors

The aim of this study is to investigate the antibacterial capabilities of different coating durations of three nanoparticle (NP) coatings: molybdenum (Mo), tantalum (Ta), and zinc oxide (ZnO), and their effects on the surface characteristics of 316L stainless steel (SS). The coated substrates underwent characterization utilizing field emission scanning electron microscopy (FE-SEM), energy dispersive X-ray spectrometry (EDX), and X-ray diffractometer (XRD) techniques. The antibacterial efficacy of NPs was evaluated using the agar diffusion method. The FE-SEM and EDX images confirmed the presence of nano-sized particles of Mo, Ta, and ZnO on the surface of the substrates with perfectly symmetrical spheres and a uniform distribution of

... Show More
View Publication
Scopus (4)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Computational And Theoretical Nanoscience
Three-Dimensional Seismic Response Analysis for a Rockfill Dam
...Show More Authors

View Publication
Scopus (3)
Crossref (3)
Scopus Crossref