Preferred Language
Articles
/
_RhB3pYBVTCNdQwCuYdf
Design of experiments model for optimization of spectrophotometric determination of phenylephrine hydrochloride in pure and pharmaceutical formulations using p-bromanil
...Show More Authors

A simple, fast, inexpensive and sensitive method has been proposed to screen and optimize experimental factors that effecting the determination of phenylephrine hydrochloride (PHE.HCl) in pure and pharmaceutical formulations. The method is based on the development of brown-colored charge transfer (CT) complex with p-Bromanil (p-Br) in an alkaline medium (pH=9) with 1.07 min after heating at 80 °C. ‘Design of Experiments’ (DOE) employing ‘Central Composite Face Centered Design’ (CCF) and ‘Response Surface Methodology’ (RSM) were applied as an improvement to traditional ‘One Variable at Time’ (OVAT) approach to evaluate the effects of variations in selected factors (volume of 5×10-3 M p-Br, heating time, and temperature) on the formation of the colored complex Y (absorbance) as graphical interpretation for robustness. The product was spectrophotometrically quantified at 395 nm. Beer’s law is obeyed in the concentration range of 5-20 μg. mL−1 with detection limit of 0.4191 μg. mL−1 . The molar absorptivity and Sandell’s sensitivity were found to be 6.07×103 L.mol−1 .cm−1 and 0.03356 μg.cm−2 respectively and the resulting color was stable for more than 1h. Applications of the recommended method to (PHE.HCl) pharmaceutical formulations was achieved with regard to accuracy and precision.

Scopus
View Publication
Publication Date
Wed Nov 01 2023
Journal Name
Ecological Engineering & Environmental Technology
Synthesis of Mn-Co-Ni Composite Electrode by Anodic and Cathodic Electrodeposition for Indirect Electro-oxidation of Phenol – Optimization of the Removal by Response Surface Methodology
...Show More Authors

In the present work, Response Surface Methodology (RSM) was utilized to optimize process variables and find the best circumstances for indirect electrochemical oxidation of mimicked wastewater to remove phenol contaminants using prepared ternary composite electrode. The electrodeposition process is used for the synthesis of a ternary composite electrode of Mn, Co, and Ni oxides. The selected concentrations of metal salts of these elements were 0.05, 0.1, and 1.5 M, with constant molar ratio, current density, and electrolysis time of 1:1:1, 25 mA/cm2, and 2 h. Interestedly, the gathered Mn-Co-Ni oxides were deposited at both the anode and cathode. X-ray diffraction (XRD) and scanning electron microscopy (SEM) facilitated the qualitative char

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Crossref
Publication Date
Sat Mar 30 2019
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Study on Kinetic and Optimization of Continuous Advanced Oxidative Decolorization of Brilliant Reactive Red Dye
...Show More Authors

The azo dye brilliant reactive red K-2BP (λmax = 534 nm) is widely used for coloring textiles because of its low-cost and tolerance fastness properties. Wastewaters treatment that contains the dye by conventional ways is usually inadequate due to its resistance to biological and chemical degradation. During this study, the continuous reactor of an advanced oxidation method supported the use of H2O2/sunlight, H2O2/UV, H2O2/TiO2/sunlight, and H2O2/TiO2/UV for decolorization of brilliant reactive red dye from the effluent. The existence of an optimum pH, H2O2 concentration, TiO2 concentration, and d

... Show More
View Publication Preview PDF
Crossref (8)
Crossref
Publication Date
Sat Dec 17 2022
Journal Name
Iraqi Journal Of Laser
PDF Design Optical BPF Using Double Clad Fiber MZI for Free Space Optical Communication: Mohanad G. Khamees , Tahreer S. Mansour*
...Show More Authors

Abstract: A novel design of Mach Zehnder Interferometer (MZI) in terms of using special type of optical fiber that has double clad with graded distribution of the refractive index that can be easily implemented practically was suggested and simulated in this work. The suggested design is compact, rapid, and is simple to be modified and tested. The simulated design contains a MZI of 1546.74 nm of central wavelength that is constructed using special type of double clad optical fiber that has two different numerical apertures. The first aperture will supply single mode propagation via its core, while the second numerical aperture supports a zigzag wave propagation (multimode) in the first clad region. The interferometer’s

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2021
Journal Name
Journal Of Engineering
Performance Evaluation of Pole Placement and Linear Quadratic Regulator Strategies Designed for Mass-Spring-Damper System Based on Simulated Annealing and Ant Colony Optimization
...Show More Authors

This paper investigates the performance evaluation of two state feedback controllers, Pole Placement (PP) and Linear Quadratic Regulator (LQR). The two controllers are designed for a Mass-Spring-Damper (MSD) system found in numerous applications to stabilize the MSD system performance and minimize the position tracking error of the system output. The state space model of the MSD system is first developed. Then, two meta-heuristic optimizations, Simulated Annealing (SA) optimization and Ant Colony (AC) optimization are utilized to optimize feedback gains matrix K of the PP and the weighting matrices Q and R of the LQR to make the MSD system reach stabilization and reduce the oscillation of the response. The Matlab softwar

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Apr 14 2016
Journal Name
Iraqi Journal Of Market Research And Consumer Protection
Determination of Some Biochemical Parameters in Ascaridia galli in chickens Which abundant in the local markets: Determination of Some Biochemical Parameters in Ascaridia galli in chickens Which abundant in the local markets
...Show More Authors

The current study included measuring the percent of protein in the extract of nematode Ascaridia galli that infect chickens, it was 1.157% and equivalent to 11.570 mg /L., as well as the amino acid analysis in the nematode A.galli by using a high-performance liquid chromatography technique (HPLC), as was detect five types for amino acids in this extract Leucine, Threonin, Serine, Methionine and Valine as the amount of these amino acids in the extract was as follows 132.973, 26.994, 10.453, 2.243 and 1.888 mg /L., respectively, and other amino acids which Glutamic, Histidine and Tyrosin did not exist in the nematode A.galli.

View Publication Preview PDF
Publication Date
Sat Dec 01 2012
Journal Name
Journal Of Economics And Administrative Sciences
ESTIMATION OF COEFFICIENTS AND SCALE PARAMETER FOR LINEAR (TYPE 1) EXTREME VALUE REGRESSION MODEL FOR LARGEST VALUES WITH APPLICATIONS
...Show More Authors

In this paper we estimate the coefficients and scale parameter in linear regression model depending on the residuals are of type 1 of extreme  value distribution for the largest values . This can be regard as an improvement for the studies with the smallest values . We study two estimation methods ( OLS  & MLE ) where we resort to Newton – Raphson (NR) and Fisher Scoring methods to get MLE estimate because the difficulty of using the usual approach with MLE . The relative efficiency criterion is considered beside to the statistical inference procedures for the extreme value regression model of type 1 for largest values . Confidence interval , hypothesis testing for both scale parameter and regression coefficients

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
Scopus (5)
Scopus Crossref
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
View Publication
Scopus (5)
Scopus Clarivate Crossref
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
View Publication
Scopus (5)
Scopus Clarivate Crossref
Publication Date
Sun Oct 01 2017
Journal Name
International Journal Of Hydrogen Energy
Determination of best possible correlation for gas compressibility factor to accurately predict the initial gas reserves in gas-hydrocarbon reservoirs
...Show More Authors

Gas compressibility factor or z-factor plays an important role in many engineering applications related to oil and gas exploration and production, such as gas production, gas metering, pipeline design, estimation of gas initially in place (GIIP), and ultimate recovery (UR) of gas from a reservoir. There are many z-factor correlations which are either derived from Equation of State or empirically based on certain observation through regression analysis. However, the results of the z-factor obtained from different correlations have high level of variance for the same gas sample under the same pressure and temperature. It is quite challenging to determine the most accurate correlation which provides accurate estimate for a range of pressures,

... Show More
View Publication
Scopus (31)
Crossref (32)
Scopus Clarivate Crossref