Abstract-Servo motors are important parts of industry automation due to their several advantages such as cost and energy efficiency, simple design, and flexibility. However, the position control of the servo motor is a difficult task because of different factors of external disturbances, nonlinearities, and uncertainties. To tackle these challenges, an adaptive integral sliding mode control (AISMC) is proposed, in which a novel bidirectional adaptive law is constructed to reduce the control chattering. The proposed control has three steps to be designed. Firstly, a full-order integral sliding manifold is designed to improve the servo motor position tracking performance, in which the reaching phase is eliminated to achieve the invariance of the ISMC in the motor system response. Secondly, the bidirectional adaptive law of the switching gain is proposed to mitigate the chattering. In the proposed bidirectional adaptive law, the switching gain varies depending on the system uncertainties, providing the high switching gain initially and then moving to the lowest value when sliding mode is achieved. As a result, not only the overestimation issues of monotonically adaptive law are resolved, but also the prior information of the disturbance upper bound is no longer required. Thirdly, by using the Lyapunov theorem, the stability of the controlled servo system is mathematically proved. Finally, simulation tests are conducted to confirm the superiority of tracking and robustness of the proposed control algorithm over existing control algorithms in terms of position-tracking responses and chattering reduction.
Background. The motor response is a fundamental ability that is evident during any physical or motor activity. However, the need for this ability varies from one sport to another and depends on the specific skills required in each sport. Objectives. This study aims to compare the average motor reaction times of the arm and leg among handball, basketball, and volleyball players aged 14 to 16 years. Methods. The sample included 30 players aged 14-16 years from the sports talent care center, evenly distributed on handball, basketball, and volleyball. Standardized tests were used to measure the speed of motor response, including the Batak Micro test for hands, which records the number of responses to light stimuli in 30 seconds, and the Saqer t
... Show MoreThis research adopts the estimation of mass transfer coefficient in batch packed bed distillation column as function of physical properties, liquid to vapour molar rates ratio (L / V), relative volatility (α), ratio of vapour and liquid diffusivities (DV / DL), ratio of vapour and liquid densities (ρV / ρL), ratio of vapour and liquid viscosities (μV/ μL).
The experiments are done using binary systems, (Ethanol Water), (Methanol Water), (Methanol Ethanol), (Benzene Hexane), (Benzene Toluene). Statistical program (multiple regression analysis) is used for estimating the overall mass transfer coefficient of vapour and liquid phases (KOV and KOL) in a correlation which represented the data fairly well.
KOV = 3.3 * 10-10
... Show MoreThe research aims to identify: 1-Designing a test to measure the movement compatibility of the eye and the leg for the students of the Faculty of Physical Education and Sports Sciences, Samarra University. 2-Codification (setting scores and standard levels) for the results of the motor compatibility test for the eye and the leg for students of the Faculty of Physical Education and Sports Sciences, Samarra University. The researchers reached the some following conclusions: 1-A test to measure the movement compatibility of the eye and the leg for the students of the Faculty of Physical Education and Sports Sciences. 2-There is a discrepancy in the standard levels of the research sample.
Multivariate Non-Parametric control charts were used to monitoring the data that generated by using the simulation, whether they are within control limits or not. Since that non-parametric methods do not require any assumptions about the distribution of the data. This research aims to apply the multivariate non-parametric quality control methods, which are Multivariate Wilcoxon Signed-Rank ( ) , kernel principal component analysis (KPCA) and k-nearest neighbor ( −
ECG is an important tool for the primary diagnosis of heart diseases, which shows the electrophysiology of the heart. In our method, a single maternal abdominal ECG signal is taken as an input signal and the maternal P-QRS-T complexes of original signal is averaged and repeated and taken as a reference signal. LMS and RLS adaptive filters algorithms are applied. The results showed that the fetal ECGs have been successfully detected. The accuracy of Daisy database was up to 84% of LMS and 88% of RLS while PhysioNet was up to 98% and 96% for LMS and RLS respectively.