Preferred Language
Articles
/
ZxgEo5gBVTCNdQwCJMAQ
Synthesis, Spectral Characterization, DNA Cleavage, and Antioxidant Properties of Metal Complexes with a Novel Schiff Base Ligand Derived from 4-Chlorobenzoic Acid
...Show More Authors

A novel Schiff base ligand (DBC) synthesized from 4-chlorobenzoic acid, along with its Cu (II) and Co (II) complexes, was prepared and characterized using FT-IR, 1H and 13C-NMR, UV-Vis spectroscopy, as well as magnetic and conductivity measurements. Based on this, a tetrahedral structure of [M(DBC)Cl2] was proposed for the complexes. Antioxidant activity of the compounds was assessed and compared to ascorbic acid, revealing that the copper complex exhibited superior antioxidant properties compared to the cobalt complex and the ligand. Furthermore, the antibiofilm potential of the copper and cobalt complexes was assessed against five clinically relevant bacterial species (P.aeruginosa, E.coli, K.pneumoniae, S.aureus and S.typhi) using various concentrations. Biofilm inhibition was quantified through optical density measurements, revealing that the copper complex had a higher mean biofilm inhibition compared to the cobalt complex at the maximum concentration of 1000 mg/ml. Optical density measurements also indicated reduced biofilm formation with increasing metal concentrations, particularly for the copper complex. Additionally, agarose gel electrophoresis showed significant alterations in plasmid DNA profiles of bacterial isolates upon exposure to the complexes, indicating potential genetic changes and implications for bacterial adaptation.

Scopus Crossref
View Publication
Publication Date
Wed Mar 18 2020
Journal Name
Baghdad Science Journal
Spectrophotometric Determination of Copper(II) using 2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole](MBBAI)
...Show More Authors

            Spectrophotometric method was developed for the determination of copper(II) ion. Synthesized (2,2[O-Tolidine-4,4-bis azo]bis[4,5-diphenyl imidazole]) (MBBAI) was used as chromogenic reagent at pH=5. Various factors affecting complex formation, such as, pH effect, reagent concentration, time effect and temperature effect, have been considered and studied. Under optimum conditions concentration ranged from (5.00-80.00) µg/mL of copper(II) obeyed Beer`s Low. Maximum absorption of the complex was 409nm with molar absorpitivity 0.127x104 L mol-1 cm-1. Limit of detection(LOD) and Limit of quantification were 1.924 and 6.42 μg/mL, respectively.

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Feb 01 2023
Journal Name
South African Journal Of Botany
Ability of FeNi3/SiO2/TiO2 nanocomposite to degrade amoxicillin in wastewater samples in solar light-driven processes
...Show More Authors

View Publication
Scopus (20)
Crossref (17)
Scopus Clarivate Crossref
Publication Date
Thu Jan 19 2023
Journal Name
Plos One
Knowledge sharing behaviour among head nurses in online health communities: The moderating role of knowledge self-efficacy
...Show More Authors
Background

Head nurses are vital in understanding and encouraging knowledge sharing among their followers. However, few empirical studies have highlighted their contribution to knowledge-sharing behaviour in Online Health Communities (OHCs). In addition, scant literature has examined the moderating role of knowledge self-efficacy in this regard.

Purposes

This study examines the moderating role of self-efficacy between the association of four selected individual factors of head nurses (i.e., Trust, Reciprocity, Reputation, and Ability to Share) and their knowledge-sharing behaviour in OHCs in Jordan.

<
... Show More
View Publication
Scopus (17)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Sun Jun 02 2019
Journal Name
Baghdad Science Journal
New Fluorometric Method for the Determination of Ketotifen Fumarate Using Continuous Flow Injection Analysis via ISNAG-fluorimeter
...Show More Authors

        A newly developed analytical method was conducted for the determination of Ketotifen fumarate (KTF) in pharmaceuticals drugs via quenching of continuous fluorescence of 9(10H)-Acridone (ACD). The method was applied using flow injection system of a new homemade ISNAG fluorimeter with fluorescence measurements at ± 90◦ via 2×4 solar cell. The calibration graph was linear in the range of 1-45 mmol/L, with correlation coefficient r = 0.9762 and the limit of detection 29.785 µg/sample from the stepwise dilution for the minimum concentration in the linear dynamic ranged of the calibration graph. The method was successfully applied to the determination of Ketotifen fumarate in two different pharma

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Dec 22 2022
Journal Name
Chemistry &amp; Chemical Technology
Turbidimetric Determination of Mebeverine Hydrochloride in Pharmaceutical Formulations Using Two Consecutive Detection Zones under Continuous Flow Conditions
...Show More Authors

A simple, low cost and rapid flow injection turbidimetric method was developed and validated for mebeverine hydrochloride (MBH) determination in pharmaceutical preparations. The developed method is based on forming of a white, turbid ion-pair product as a result of a reaction between the MBH and sodium persulfate in a closed flow injection system where the sodium persulfate is used as precipitation reagent. The turbidity of the formed complex was measured at the detection angle of 180° (attenuated detection) using NAG dual&Solo (0-180°) detector which contained dual detections zones (i.e., measuring cells 1 & 2). The increase in the turbidity of the complex was directly proportional to the increase of the MBH concentration

... Show More
Scopus (19)
Crossref (13)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Ieee Access
Implementation of Univariate Paradigm for Streamflow Simulation Using Hybrid Data-Driven Model: Case Study in Tropical Region
...Show More Authors

View Publication
Scopus (95)
Crossref (92)
Scopus Clarivate Crossref
Publication Date
Tue Oct 02 2018
Journal Name
Iraqi Journal Of Physics
Enhancement the sensitivity of humidity sensor based on an agarose infiltration reflection-type photonic crystal fiber interferometer
...Show More Authors

Photonic Crystal Fiber Interferometers (PCFIs) are widely used for sensing applications. This work presents the fabrication and study the characterization of a relative humidity sensor based on a polymer-infiltrated photonic crystal fiber that operates in a Mach- Zehnder Interferometer (MZI) reflection mode. The fabrication of the sensor only involves splicing and cleaving Photonic Crystal Fiber (PCF) with Single Mode Fiber (SMF). A stub of (LMA-10) PCF spliced to SMF (Corning-28). In the splice regions. The PCFI sensor operation based on the adsorption and desorption of water vapour at the silica-air interface within the PCF. The sensor shows a high sensitivity to RH variations from (27% RH - 95% RH), with a change in its reflected powe

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Mar 15 2026
Journal Name
Journal Of Research In Pharmacy
In-vivo examination of nasal-to-brain administration for delivering rhodamine B nanospanlastic for fluorescent vesicle imaging
...Show More Authors

This study investigated the efficacy of nasal injection of rhodamine B nanospanlastic (RBN) for magnetic vesicle imaging of specific brain locations. Effective delivery of RBN, which functions as fluorescence agents, to specific brain regions is necessary to achieve fluorescence particle imaging (FPI). There has been interest in nasal administration as a means of administering drugs directly to the brain, thereby circumventing the blood-brain barrier. We offered experimental nasal fluorescence agent administration by in vivo research. Fluorescent tests confirmed that, upon nasal delivery, the intended nanospanlastic migrated into the brain. Furthermore, using fluorescent microscopy, we demonstrated how these nanospanla

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Wed Jan 01 2014
Journal Name
Journal Of The College Of Languages (jcl)
EL ANÁLISIS DE ERRORES DEL LEÍSMO Y LAÍSMO EN EL PAPEL DIDÁCTICO PARA LOS ALUMNOS DEL DEPARTAMENTO ESPAÑOLEN LA FACULTAD DE LENGUAS EN IRAK Search Summary: The analysis of the mistakes of the personal pronouns in effect replaces him in the
...Show More Authors

During the educational practices in the Spanish department at the Faculty of Languages ​​, University of Baghdad , we noticed that the personal pronouns in effect replaced by the direct and indirect characterized hardly be expressed , and the difficulty of her education.

Rationale: I chose this topic because the personal pronouns differ between the Spanish language and the Arabic language. We believe that this study may be useful not only for language teachers, but also for students, because it can contribute to a greater awareness of and correct weaknesses.

Objectives: To apply the model from which to address the problems in the use of personal pronouns Spanish , and the difference between effect of direct and indire

... Show More
View Publication Preview PDF
Publication Date
Wed Apr 30 2025
Journal Name
Iraqi Journal Of Science
Determination of Cobalt(II) Ion in Various Selected Alloys via Utilizing Continous Flow Injection Analysis ((CFIA) (Nagham-Four Sources of White  Snow LED Arranged in Three Rows Corresponding to Three Detectors Analyzer) (NAG-4SX3-3D)) Analyzer at 0-180o Angle
...Show More Authors

The research study focuses on the efficient and accurate detection and determination of cobalt ions. The detection method involves the formation of brilliant green aggregates with calcium hexacyanoferrate in the presence of nitric acid. (Nagham-four sources of white snow light-emitting diodes arranged in three rows corresponding to three detectors) (The NAG-4SX3-3D Analyzer is an optical, chemical, electronic, and detection tool that receives a cumulative signal (no amplification is required). The total distance travelled is 760 mm with regard to YZ(mV) - tsec (dmm). It was selected for its precise calculation of the energy transducer profile. The linear range for measuring cobalt (II) ions is 0.05 to 20 mM. For concentrations of 5

... Show More
View Publication
Scopus (2)
Crossref (4)
Scopus Crossref