Preferred Language
Articles
/
ZxfaNI8BVTCNdQwCVGHm
The Accuracy of Intraoral Registration for Dynamic Surgical Navigation in the Edentulous Maxilla
...Show More Authors

Purpose: Despite the high clinical accuracy of dynamic navigation, inherent sources of error exist. The purpose of this study was to improve the accuracy of dynamic navigated surgical procedures in the edentulous maxilla by identifying the optimal configuration of intra-oral points that results in the lowest possible registration error for direct clinical implementation. Materials and methods: Six different 4-area configurations were tested by 3 operators against positive and negative controls (8-areas and 3-areas, respectively) using a skull model. The two dynamic navigation systems (X-Guide® and NaviDent®) and the two registration methods (bone surface tracing and fiducial markers) produced four registration groups. The accuracy of the registration was checked at the frontal process of the zygoma. Intra- and inter- operator reliability for each registration group were reported. Multiple comparisons were conducted to find the best configuration with the minimum registration error. Results: Ranking revealed one configuration in the tracing groups (Conf.3) and two configurations in the fiducial groups (Conf.3 and Conf.5) that had the best accuracy. When the inferior surfaces of the zygomatic buttress were excluded, fiducial registration produced better accuracy with both systems (p 0.006 and <0.0001). However, tracing 1 cm areas at these surfaces bilaterally resulted in similar registration accuracy as placing fiducial markers there (p 0.430 and 0.237). NaviDent® performed generally better (p 0.049, 0.001 and 0.002) albeit having a wider margin of uncertainty in the obtained values. Changing the distribution of the 4 tracing areas or fiducial markers had a less pronounced effect with X-Guide® than with the NaviDent® system. Conclusion: For edentulous maxillary surgeries, 4 fiducial markers placed according to configuration 3 or 5 result in the lowest registration error. Where implants are being placed bilaterally, an additional 2 sites may reduce the error further. For bilateral zygomatic implant placement, it is optimal to place 2 fiducials on the inferior surfaces of the maxillary tuberosities, other 2 on their buccal surfaces, and 2 on the anterior labial surface of the alveolar bone. Utilising the inferior zygomatic buttress is recommended over the inferior maxillary tuberosities in other types of maxillary surgeries.

Scopus Clarivate Crossref
View Publication
Publication Date
Wed Feb 14 2024
Journal Name
Russian Journal Of General Chemistry
Preparation, Characterization, and Biological Activity of Mixed Schiff Base Ligand Complexes with Amino Acid L-Proline
...Show More Authors

View Publication
Scopus (10)
Crossref (10)
Scopus Crossref
Publication Date
Mon Nov 01 2021
Journal Name
Energy Reports
Global solar radiation prediction over North Dakota using air temperature: Development of novel hybrid intelligence model
...Show More Authors

View Publication
Scopus (80)
Crossref (81)
Scopus Clarivate Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Journal Of Water Process Engineering
Immobilization of cobalt ions using hierarchically porous 4A zeolite-based carbon composites: Ion-exchange and solidification
...Show More Authors

View Publication
Scopus (62)
Crossref (53)
Scopus Clarivate Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Asian Journal Of Chemistry
Zwitterionic Ion Chromatography of Dansyl Amino Acids with 4-Vinylbenzyl Dimethyl Ammonio Pentanesulfonate as Stationary Phase
...Show More Authors

View Publication
Scopus (32)
Crossref (8)
Scopus Crossref
Publication Date
Thu Nov 02 2023
Journal Name
Journal Of Engineering
Constructing a Sustainable Roller Compacted Concrete Using Waste Demolished Material as Replacement of Cement: A Review
...Show More Authors

Roller Compacted Concrete is a type of concrete that is environmentally friendly and more economical than traditional concrete. Roller Compacted Concrete is typically used for heavy-duty and specialist constructions, such as hydraulic structures and pavements, because of its coarse surface. The main difference between RCC and conventional concrete mixtures is that RCC has a more significant proportion of fine aggregates that allow compaction and tight packing. In recent years, it has been estimated that several million tons of waste demolished material (WDM) produced each year are directed to landfills worldwide without being recycled for disposal. This review aimed to study the literature about creating a Roller-Comp

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
Optical Materials
Design and analysis of a high sensitivity open microchannel PCF-based surface plasmon resonance refractometric sensor
...Show More Authors

View Publication
Scopus (31)
Crossref (32)
Scopus Clarivate Crossref
Publication Date
Mon Jul 28 2025
Journal Name
Structural Concrete
Behavior of axially loaded concrete composite columns encased with <scp>GFRP</scp> and steel I‐sections
...Show More Authors
Abstract<p>The aim of this investigation is to evaluate the experimental and numerical effectiveness of a new kind of composite column by using Glass Fiber‐Reinforced Polymer (GFRP) I‐section as well as steel I‐section in comparison to the typical reinforced concrete one. The experimental part included testing six composite columns categorized into two groups according to the slenderness ratio and tested under concentric axial load. Each group contains three specimens with the same dimensions and length, while different cross‐section configurations were used. Columns with reinforced concrete cross‐section (reference column), encased GFRP I‐section, and encased steel I‐section were adopted in each </p> ... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Aug 13 2025
Journal Name
Molecular Crystals And Liquid Crystals
Synthesis, characterization and mesomorphic behavior of twin pyrazole ligands and their metal complexes containing dithiocarbamat units
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Mon Dec 01 2025
Journal Name
Applied Thermal Engineering
Efficient thermal management of PVT systems via water-PCM hybridization: New design with optimized geometrical configuration
...Show More Authors

Temperature regulation is critical for photovoltaic (PV) systems, as excessive operating temperatures significantly reduce electrical efficiency and accelerate material degradation. This study addresses this challenge through a novel hybrid cooling approach that combines active water cooling with passive PCM-based thermal management in PVT systems. A three-dimensional numerical investigation was conducted to evaluate the thermal and electrical performance of the proposed hybrid configuration against conventional alternatives. The water-PCM hybrid system demonstrated superior cooling effectiveness, maintaining PV panel temperatures 5.5 K lower than water-only cooling systems, resulting in a 2.48 % relative improvement in electrical efficienc

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sat Jun 01 2024
Journal Name
Applied Thermal Engineering
Design and optimization of a household photovoltaic/thermal collector with serpentine tube: Energy and exergy analysis
...Show More Authors

Hybrid photovoltaic/thermal (PV/T) collectors that simultaneously generate electricity and heat have promise for sustainable energy production. However, their performance depends strongly on four key design parameters. These are: panel aspect ratio, serpentine tube pitch, solar intensity, and coolant flow rate. This study optimized these design parameters for a household serpentine-tube PV/T collector using energy and exergy analysis to enhance electrical and thermal efficiencies. Response surface methodology was employed to model the complex relationships between these parameters and the electrical and thermal efficiency responses. Increasing the panel aspect ratio from 0.125 to 8 resulted in 1.99 and 12.10 % improvements for electrical an

... Show More
View Publication
Scopus (23)
Crossref (25)
Scopus Crossref