Preferred Language
Articles
/
ZHgi4qABuRolNscLafQw
Distribution system performance improvement by optimal renewable energy placement using swarm algorithms
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Sat Dec 31 2022
Journal Name
Journal Of Life Science And Applied Research
THE ROLE OF OPTIFEED®, VÊO® PREMIUM, AND OLEOBIOTEC® IN DIETS FOR IMPROVEMENT OF THE PRODUCTION PERFORMANCE OF MALE BROILERS IN HEAT STRESS
...Show More Authors

The present study was conducted to investigate the effect of adding various levels of Optifeed®, VêO® premium and Oleobiotec® to the diets as appetite stimulants in the production Performance of broiler males under heat stress conditions. The experiment was done for 42 days for the period from 30 August 2018 to 11 of October 2018 at the Poultry Research Station of the Livestock Research Department / Agricultural Research Department / Ministry of Agriculture (Baghdad - Abu Ghraib). In this study, 270 - one-day broiler males (Ross 308) were reared with the mean body weight of 37 g/chick, distributed randomly on 18 pens with dimensions of 2 x 3 m (length x width). The experimental treatments involved six treatments with three repli

... Show More
View Publication
Crossref (13)
Crossref
Publication Date
Fri Mar 01 2019
Journal Name
Al-khwarizmi Engineering Journal
Performance Estimation of Heat Exchanger Operates By Evaporative Cooling Manner
...Show More Authors

        In this study the design and installation of evaporative air cooler was carried out using completely outdoor air (fresh air) according to two stage evaporative cooling principle. The laboratory equipment was installed by designing and manufacturing a cross flow plate heat exchanger, where aluminum plates used for this purpose with dimensions (50 × 30 × 40 cm). The surfaces of heat exchanger were covered by sawdust from wetted channels side, to increase the percentage of wetting these surfaces and hence improve the performance and efficiency of air cooler.

        An experimental study was carried out to estimate the performance of cooling system, where som

... Show More
View Publication Preview PDF
Publication Date
Sat Mar 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying the Performance of Refrigeration Units Powered by Solar Panel
...Show More Authors

An experimental study was conducted to determine the performance of a solar electric refrigeration system. The system contained flat photovoltaic solar panel which absorbs the solar energy and convert it to electrical energy, used to run the refrigeration cycle. Two refrigeration cycles with electrical solar panel were used over a period of 12 months, the first one with classical parts known in refrigeration cycle, while the second one introduced heat exchanger which improves the coefficient of performance by saving the consumed energy. The coefficient of performance of these refrigeration cycles with compressor efficiency 85% are 2.102 and 2.57 respectively. The overall efficiency of the two systems are 18.9% and 23.13%.

View Publication Preview PDF
Publication Date
Thu Sep 01 2022
Journal Name
Iraqi Journal Of Physics
Producing Hydrogen Energy Using Cr2O3-TNFs Nanocomposite with Animal (Chitosan) Extract via Ultrasonic and Hydrothermal Techniques
...Show More Authors

In this study, an efficient photocatalyst for dissociation of water was prepared and studied. The chromium oxide (Cr2O3) with Titanium dioxide (TiO2) nanofibers (Cr2O3-TNFs) nanocomposite with (chitosan extract) were synthesized using ecologically friendly methods such as ultrasonic and hydrothermal techniques; such TiO2 exhibits nanofibers (TNFs) shape struct

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Aug 01 2019
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
Evaluation of routing protocol with multi-mobile sinks in WSNs using QoS and energy consumption parameters
...Show More Authors

An efficient networks’ energy consumption and Quality of Services (QoS) are considered the most important issues, to evaluate the route quality of the designed routing protocol in Wireless Sensor Networks (WSNs). This study is presented an evaluation performance technique to evaluate two routing protocols: Secure for Mobile Sink Node location using Dynamic Routing Protocol (SMSNDRP) and routing protocol that used K-means algorithm to form Data Gathered Path (KM-DGP), on small and large network with Group of Mobile Sinks (GMSs). The propose technique is based on QoS and sensor nodes’ energy consumption parameters to assess route quality and networks’ energy usage. The evaluation technique is conducted on two routing protocols i

... Show More
View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sun Apr 08 2018
Journal Name
Al-khwarizmi Engineering Journal
Energy Consumption Analyzing in Single hop Transmission and Multi-hop Transmission for using Wireless Sensor Networks
...Show More Authors

Wireless sensor networks (WSNs) are emerging in various application like military, area monitoring, health monitoring, industry monitoring and many more. The challenges of the successful WSN application are the energy consumption problem. since the small, portable batteries integrated into the sensor chips cannot be re-charged easily from an economical point of view. This work focusses on prolonging the network lifetime of WSNs by reducing and balancing energy consumption during routing process from hop number point of view. In this paper, performance simulation was done between two types of protocols LEACH that uses single hop path and MODLEACH that uses multi hop path by using Intel Care i3 CPU (2.13GHz) laptop with MATLAB (R2014a). Th

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Performance of concrete thrust block at several burial conditions under the influence of thrust forces generated in the water distribution networks
...Show More Authors
Abstract<p>This study was prepared to investigate the performance and behavior of concrete thrust blocks supporting pipe fittings. In the water distribution networks, it is always necessary to change the path of the pipes at different degrees or to create new branches. In these regions, an unbalanced force called the thrust force is generated. In order to counter this force, these regions are supported with concrete blocks. In this article, the system components (soil, pipe with its bend and thrust blocks) have been numerically modeled and simulated by the ABAQUS CAE/2019 software program in order to study the behavior and stability of the thrust block with different burial conditions (several b</p> ... Show More
View Publication Preview PDF
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Effect of laser energy and pulses on size and concentration of gold nanoparticles in DDDW by LALP method
...Show More Authors

The size and the concentration of the gold nanoparticles (GNPs)
synthesized in double distilled deionized water (DDDW) have been
found to be affected by the laser energy and the number of pulses.
The absorption spectra of the nanoparticles DDDW, and the
surface plasmon resonance (SPR) peaks were measured, and found to
be located between (509 and 524)nm using the UV- Vis
spectrophotometer. SPR calculations, images of transmission
electron microscope, and dynamic light scattering (DLS) method
were used to determine the size of GNPs, which found to be ranged
between (3.5 and 27) nm. The concentrations of GNPs in colloidal
solutions found to be ranged between (37 and 142) ppm, and
measured by atomic absorptio

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Sep 20 2023
Journal Name
Chalcogenide Letters
Calculation of the localized and extended energy states density for Ge60Se40-xTex alloy prepared by melting point method
...Show More Authors

The DC electrical conductivity properties of Ge60Se40-xTex alloy with x = 0, 5, 10, 15 and 20). The samples were formed in the form of discs with the thickness of 0.25–0.30 cm and the diameter of 1.5 cm. Samples were pressed under a pressure of 6 tons per cm2 , using a ton hydraulic press. They were prepared after being pressed using a ton hydraulic press using a hydraulic press. Melting point technology use to preper the samples. Continuous electrical conductivity properties were recorded from room temperature to 475 K. Experimental data indicates that glass containing 15% Te has the highest electrical conductivity allowing maximum current through the sample compared to Lu with other samples. Therefore, it is found that the DC co

... Show More
View Publication
Scopus (3)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Feb 07 2026
Journal Name
Journal Of Engineering And Applied Science
Thermal performance of a pulsating heat pipe heat exchanger for energy recovery in air conditioning systems in a high-ambient temperature country
...Show More Authors

View Publication
Scopus (2)
Crossref (2)
Scopus Crossref