Abstract Background: The novel coronavirus 2 (SARS?CoV?2) pandemic is a pulmonary disease, which leads to cardiac, hematologic, and renal complications. Anticoagulants are used for COVID-19 infected patients because the infection increases the risk of thrombosis. The world health organization (WHO), recommend prophylaxis dose of anticoagulants: (Enoxaparin or unfractionated Heparin for hospitalized patients with COVID-19 disease. This has created an urgent need to identify effective medications for COVID-19 prevention and treatment. The value of COVID-19 treatments is affected by cost-effectiveness analysis (CEA) to inform relative value and how to best maximize social welfare through evidence-based pricing decisions. Objective: compare the clinical outcome and the costs of two anticoagulants (heparin and (enoxaparin)) used to treat hospitalized patients with COVID-19 infection. Patients and method: The study was a retrospective review of medical records of adult, non-pregnant, COVID-19 infected hospitalized patients who had baseline and last outcome measurements at Alamal Epidemiology Center, Al-Najaf city from (Augast 2020 to June 2021). The outcome measures included D-dimer, length of stay (LOS), and mortality rate. Only the cost of the medical treatment was considered in the analysis. The pharmacoeconomics analysis was done in three different cost-effectiveness analysis methods. Microsoft Excel spreadsheet and Statistical Package for the Social Sciences software (SPSS), was used to conduct statistical analysis. Kaplan Meier test was used to compare the mortality rate. T-TEST was used to compare the outcomes of the two groups. Results and discussion: two groups were compared, the first group consists of 72 patients who received heparin, and the second group consists of 72 patients who received enoxaparin. COVID-19 infected patients had a higher abnormal average D-dimer (2534.675 ng/dl). No significant differences between both genders with regards to the basal average D-dimer (males= 2649.95 ng/dl, females= 2374.1mg/dl, P-value>0.05). There was a significant difference between patient's ages 60 years and patients <60. (3177.33 ng/dl, 1763.06 ng/dl, P-value <0.05). It seems that, higher D-dimer levels were associated with a higher mortality rate (died=3166.263 ng/dl, survived= 1729.94 ng/dl, P-value <0.05). Heparin was more effective in decreasing D-dimer levels than enoxaparin which inversely increased the D-dimer levels (-24.4 ng/dl/day, +154.701 ng/dl/day, P-value <0.05). Additionally, heparin was more effective in increasing the survival rate compared to enoxaparin (55% vs, 35%, P-value<0.05). Heparin was associated with a longer duration of stay in hospital than enoxaparin but with no significant difference (13.7 days, 12.3 days, P-value >0.05). Concerning the cost, treatment with heparin cost less than enoxaparin (2.08 U.S $, 9.44 U.S $)/per patient/per day. Conclusion: Originator heparin was a more cost-effective anticoagulant therapy compared to originator enoxaparin, it was associated with a lower cost and better effect, treatment with Heparin resulted in positive INB= 11.3, where a positive result means that heparin is more cost-effective than Enoxaparin. All three methods of pharmacoeconomic analysis decide that heparin was more cost-effective than enoxaparin in treating COVID-19 infected patients.
The energy requirements of corn silage harvesters and the application of precision agricultural techniques are essential for efficient and productive agricultural practices. The article aims to review previous studies on the energy requirements needed for different corn silage harvesting machines, and on the other hand, to present methods for measuring corn silage productivity directly in the field and monitoring it based on microcontrollers and artificial intelligence techniques. The process of making corn silage is done by cutting green fodder plants into small pieces, so special harvesters are used for this, called corn silage harvesters. The purpose of harvesting corn silage is to efficiently collect and store as many digestible nutrien
... Show MoreA new 5‐fluorouracil–naproxen conjugate is synthesized as a mutual prodrug for targeting cancer tissues. The structure of the target compound and their intermediate are characterized by their melting point, IR, 1H NMR, 13C NMR, and elemental microanalysis. The cytotoxic activity is preliminarily evaluated using nonsmall lung cancer CRL‐2049, human breast cancer CAL‐51, and one type of normal cell line; rat embryo fibroblast cell line. The synthesized compound shows a good cytotoxic effect at the cancer cell and no significant effect at rat embryo fibroblast cell line.
Non uniform channelization is a crucial task in cognitive radio receivers for obtaining separate channels from the digitized wideband input signal at different intervals of time. The two main requirements in the channelizer are reconfigurability and low complexity. In this paper, a reconfigurable architecture based on a combination of Improved Coefficient Decimation Method (ICDM) and Coefficient Interpolation Method (CIM) is proposed. The proposed Hybrid Coefficient Decimation-Interpolation Method (HCDIM) based filter bank (FB) is able to realize the same number of channels realized using (ICDM) but with a maximum decimation factor divided by the interpolation factor (L), which leads to less deterioration in stop band at
... Show MoreSecure storage of confidential medical information is critical to healthcare organizations seeking to protect patient's privacy and comply with regulatory requirements. This paper presents a new scheme for secure storage of medical data using Chaskey cryptography and blockchain technology. The system uses Chaskey encryption to ensure integrity and confidentiality of medical data, blockchain technology to provide a scalable and decentralized storage solution. The system also uses Bflow segmentation and vertical segmentation technologies to enhance scalability and manage the stored data. In addition, the system uses smart contracts to enforce access control policies and other security measures. The description of the system detailing and p
... Show MoreBackground: Selenium-73 with half- life of 7.15 hour emits β+ in nature and has six stable isotopes which are ( 74Se,76Se,77Se,78Se,80Se and 82Se ). Selenium-73 has many applications in technology and radioselenium compounds of metallic have found various applications in medicine.
Objective: To make a comparison between different reactions that produced cross sections of Se-73 radioisotopes.
Subjects and methods: The feasibility of the production of Selenium -73 via various nuclear reactions was investigated. Excitation functions of 73Se production by the re
... Show MoreThe influence of an aortic aneurysm on blood flow waveforms is well established, but how to exploit this link for diagnostic purposes still remains challenging. This work uses a combination of experimental and computational modelling to study how aneurysms of various size affect the waveforms. Experimental studies are carried out on fusiform-type aneurysm models, and a comparison of results with those from a one-dimensional fluid–structure interaction model shows close agreement. Further mathematical analysis of these results allows the definition of several indicators that characterize the impact of an aneurysm on waveforms. These indicators are then further studied in a computational model of a systemic blood flow network. This demonstr
... Show More
This paper describes DC motor speed control based on optimal Linear Quadratic Regulator (LQR) technique. Controller's objective is to maintain the speed of rotation of the motor shaft with a particular step response.The controller is modeled in MATLAB environment, the simulation results show that the proposed controller gives better performance and less settling time when compared with the traditional PID controller.
A bolted–welded hybrid demountable shear connector for use in deconstructable steel–concrete composite buildings and bridges was proposed. The hybrid connector consisted of a partially threaded stud, which was welded on the flange of a steel section, and a machined steel tube with compatible geometry, which was bolted on the stud. Four standard pushout tests according to Eurocode 4 were carried out to assess the shear performance of the hybrid connector. The experimental results show that the initial stiffness, shear resistance, and slip capacity of the proposed connector were higher than those of traditional welded studs. The hybrid connector was a ductile connector, according to Eurocode 4, with slip capacity higher than 6 mm. A nonli
... Show More