Preferred Language
Articles
/
Z4betoYBIXToZYALabOl
Deformability of non-prismatic prestressed concrete beams with multiple openings of different configurations
...Show More Authors
Abstract<p>This work presents experimental research using draped prestressed steel strands to improve the load-carrying capacity of prestressed concrete non-prismatic beams with multiple openings of various designs. The short-term deflection of non-prismatic prestressed concrete beams (NPCBs) flexural members under static loading were used to evaluate this improvement. Six simply supported (NPCBs) beams, five beams with openings, and one solid specimen used as a reference beam were all tested as part of the experiment. All of the beams were subjected to a monotonic midpoint load test. The configuration of the opening (quadrilateral or circular), as well as the depth of the chords, were the variables studied in this study. In comparison to a solid beam, experimental results show that beams with openings have a lower load-carrying capacity not exceeding (2.3–10.6%) and higher mid-span deflection through all loading stages of elastic, service, and ultimate loads (14–73%), (19–44%), and (31–55%), respectively. Furthermore, specimens with circular openings had stiffer behaviour under load than those with quadrilateral openings. Beams with quadrilateral openings and inclined posts, on the other hand, were stiffer than beams with quadrilateral openings and vertical posts.</p>
Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Sep 12 2017
Journal Name
Nuclear Science And Techniques
Investigating the influence of gamma ray energies and steel fiber on attenuation properties of reactive powder concrete
...Show More Authors

View Publication
Crossref (13)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Journal Of The Mechanical Behavior Of Materials
Influence of water-absorbent polymer balls on the structural performance of reinforced concrete beam: An experimental investigation
...Show More Authors
Abstract<p>This research investigated the influence of water-absorbent polymer balls (WAPB) on reinforced concrete beams’ structural behavior experimentally. Four self-compacted reinforced concrete beams of identical geometric layouts 150 mm × 200 mm × 1,500 mm, reinforcement details, and compressive strength <inline-formula> <alternatives> <inline-graphic xmlns:xlink="http://www.w3.org/1999/xlink" xlink:href="graphic/j_jmbm-2022-0024_eq_001.png"></inline-graphic> <math xmlns:m="http://www.w3.org/1998/Math/MathML"> <msubsup> <mrow> </mrow></msubsup></math></alternatives></inline-formula></p> ... Show More
Crossref (2)
Crossref
Publication Date
Mon May 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Some Properties of Mortar and Concrete Using Brick, Glass and Tile Waste as Partial Replacement of Cement
...Show More Authors

The using of waste products as a recycled material was one of the most important studies for saving money and reduces the pollution. Mortar and concrete mixes with (10, 20 and 30)% of brick, glass and tile powder as replacement by weight of cement was investigated. The concrete mixes using brick or glass as 10%replacement of cement exhibited enhancement in compressive strength about (6, 4.7 and 2.0)% and (7.2, 5.6 and 2)% at age 7, 28 and 90 days respectively compared to reference mix. The 20% replacement of glass powder also showed an increase in the compressive strength up to (8, 6.3 and 4) %at age 7,28 and 90 days respectively compared to reference mix. Finally concrete mix using (10, 20 and 30) % tile powder as replacement of cement sho

... Show More
Publication Date
Wed Oct 11 2017
Journal Name
International Journal Of Science And Research
Effect of Elevated Temperature on the Compressive Strength of Reactive Powder Concrete (RPC) Containing Polyvinyl Chloride (PVC)
...Show More Authors

Fire is the most sever environmental condition affecting on concrete structures, thus investigating for fire safety in structural concrete is important for building construction. The slow heat transfer and strength loss enables concrete to be effective for fire resistance. Concrete structures withstand when exposed to fire according to: their thermal properties, rate of heating, characteristic properties of concrete mixes and their composition and on the duration of fire, and concerned as thermal property with other factors such as loss of mass which affected by aggregate type, moisture content, and composition of concrete mix. The present research goal is to study the effect of rising temperature on the compressive strength of the rea

... Show More
Publication Date
Thu Mar 02 2023
Journal Name
East European Journal Of Physics
Investigation of the Impact of Glass Waste in Reactive Powder Concrete on Attenuation Properties for Bremsstrahlung Ray
...Show More Authors

Reactive Powder Concrete (RPC) is one of the most advanced recent high compressive strength concrete. This work explored the effects of using glass waste as a fractional replacement for fine aggregate in reactive powder concrete at levels of 0%, 25%, 50%, and 100%. Linear and mass attenuation coefficients have been calculated as a function of the sample's thickness and bremsstrahlung energy. These coefficients were obtained using energy selective scintillation response to bremsstrahlung having an energy ranging from (0.1-1.1) MeV. In addition, the half-value thickness of the samples prepared has been investigated. It was found that there is a reversal association between the attenuation coefficient and the energy of the bremsstrahlu

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2017
Journal Name
International Journal Of Science And Research (ijsr)
Some Properties of Mortar and Concrete Using Brick, Glass and Tile Waste as Partial Replacement of Cement
...Show More Authors

The using of waste products as a recycled material was one of the most important studies for saving money and reduces the pollution. Mortar and concrete mixes with (10, 20 and 30)% of brick, glass and tile powder as replacement by weight of cement was investigated. The concrete mixes using brick or glass as 10%replacement of cement exhibited enhancement in compressive strength about (6, 4.7 and 2.0)% and (7.2, 5.6 and 2)% at age 7, 28 and 90 days respectively compared to reference mix. The 20% replacement of glass powder also showed an increase in the compressive strength up to (8, 6.3 and 4) %at age 7,28 and 90 days respectively compared to reference mix. Finally concrete mix using (10, 20 and 30) % tile powder as replacement of cement sho

... Show More
Publication Date
Wed May 24 2017
Journal Name
International Journal Of Science And Research (ijsr)
Some Properties of Mortar and Concrete Using Brick, Glass and Tile Waste as Partial Replacement of Cement
...Show More Authors

The using of waste products as a recycled material was one of the most important studies for saving money and reduces the pollution. Mortar and concrete mixes with (10, 20 and 30)% of brick, glass and tile powder as replacement by weight of cement was investigated. The concrete mixes using brick or glass as 10%replacement of cement exhibited enhancement in compressive strength about (6, 4.7 and 2.0)% and (7.2, 5.6 and 2)% at age 7, 28 and 90 days respectively compared to reference mix. The 20% replacement of glass powder also showed an increase in the compressive strength up to (8, 6.3 and 4) %at age 7,28 and 90 days respectively compared to reference mix. Finally concrete mix using (10, 20 and 30) % tile powder as replacement of cement sho

... Show More
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Engineering
Assessing the Influence of Moisture Damage under Repeated Load on Multilayer Interface Bond Strength of Asphalt Concrete
...Show More Authors

The performance and durability of the asphalt pavement structure mainly depend on the strength of the bonding between the layers. Such a bond is achieved through the use of an adhesive material (tack coat) to bond the asphalt layers. The main objective of this study is to evaluate the effect of moisture in conjunction with repeated traffic loads on the strength of the bonding between asphalt layers using two types of tack coats with different application rates. Using the nominal maximum size of aggregate (NMAS), the layers were graded (25/19) and (19/9.5) mm. The slabs of multilayer asphalt concrete were prepared using a roller compactor using two types of tack coats to bond between layers, namely rapid curing cut back a

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Wed Dec 01 2021
Journal Name
Structures
The effect of ground motion characteristics on the fragility analysis of reinforced concrete frame buildings in Australia
...Show More Authors

View Publication
Crossref (14)
Crossref
Publication Date
Sat Jul 22 2023
Journal Name
Journal Of Engineering
Effect of Fire Flame (High Temperature) on the Self Compacted Concrete (SCC) One Way Slabs
...Show More Authors

Experimental work was carried out to investigate the effect of fire flame (high temperature) on specimens of one way slabs using Self Compacted Concrete (SCC). By using furnace manufactured for this purpose, twenty one reinforced concrete slab specimens were exposed to direct fire flame. All of specimens have the same dimensions. The slab specimens were cooled in two types, gradually by left them in the air and suddenly by using water. After that the specimens were tested under two point loads, to study, the effect of
different: temperature levels (300ºC, 500ºC and 700ºC), and cooling rate (gradually and sudden cooling conditions) on the concrete compressive strength, modulus of rupture, flexural strength and the behavior of reinf

... Show More
View Publication Preview PDF
Crossref (4)
Crossref