Preferred Language
Articles
/
YobdtoYBIXToZYALYrN1
Performance of reinforced concrete non-prismatic beams having multiple openings configurations
...Show More Authors
Abstract<p>This experimental study demonstrates the gable-reinforced concrete beams’ behavior with several number of openings (six and eight) and posts’ inclination, aimed to find the strength reduction in this type of beam. The major results found are: for the openings extending over similar beam length it is better to increase the number of posts (openings), <italic>i.e.</italic>, increasing opening number led to decrease in opening area, which allows us to transmit stresses and act as lever arms between the upper and the lower chords. Also, findings revealed that the inclined posts have larger loading at the mid-point relative to vertical ones. For gables with vertical posts having six and eight openings, the ultimate strength reduction was 31.5 and 25.6%, whereas it was 29 and 17.3% for those with inclined posts, respectively.</p>
Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Sun Jan 01 2006
Journal Name
J Bagh College Of Dentistry
Assessment of diametral tensile strength and microhardness of Glass ionomer reinforced by different amounts of Hydroxyapatite
...Show More Authors

Back ground: Glass ionomer materials lack resistance to wear and pressure and are susceptible to moisture during the initial stages of setting and dehydration. So this study was done to assess diametral tensile strength and microhardness of glass ionomer reinforced by different amounts of hydroxyapatite. Materials and methods: In this study a hydroxyapatite material was added to glass monomer cement at different ratios: 10%, 15%, 20%, 25% and 30% (by weight). The diametral tensile strength test described by the British standard specification for zinc polycarboxylate cement was used in this study and the microhardness test was performed using Vickers microhardness testing machine and the microhardness values were calculated and statistical c

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 02 2016
Journal Name
Iraqi Postgraduate Medical Journal
Wallplasty Versus Non Wallplasty in Arthroscopically Assisted Anterior Cruciate Ligament Reconstruction
...Show More Authors

Abstract ABSTRACT:BACKGROUND: Anterior cruciate ligament reconstruction (ACLR) is one of the most commonly performed orthopedic procedures. Technical factors especially correct tunnel placement play major role in its success. However its failure rate is still high (10%), and impingement of the graft on the posterior cruciate ligament (PCL) and the medial wall of the lateral femoral condyle is an important cause of failure. Wallplasty is a technique used to prevent graft impingement, but there is no consensus on its routine use.OBJECTIVE:Is to compare between the postoperative knee functional outcome and stability of arthroscopic ACLR performed with wallplasty versus those performed without wallplasty.PATIENTS AND METHODS: A prospective exp

... Show More
Preview PDF
Publication Date
Wed Oct 18 2017
Journal Name
Al-kindy College Medical Journal
Non Motor Symptoms In Patients With parkinson's Disease In Baghdad Hospitals
...Show More Authors

Background:Parkinson’disease(PD) is a neurodegenerative disorder of the central nervous system characterized by resting tremor, bradykinesia, cogwheel rigidity, and impairment of postural reflexes; the frequency of PD increases with aging.Clinically Parkinson's disease characterized by two groups of symptoms: motor and non-motor symptoms.Non-motor symptoms can be categorized as autonomic, cognitive/psychiatric (may include depression, dementia, anxiety, hallucinations), sensory and rapid eye movements (REM) sleep behavior disorder (RBD).

Objectives:The objectives of this study are to find out the frequency of the non-motor symptoms of idiopathic Parkinson disease in a group of patients in Baghd

... Show More
View Publication
Crossref (2)
Crossref
Publication Date
Thu Apr 18 2019
Journal Name
Al-kindy College Medical Journal
Non Traumatic Acute Abdominal pain (100 days study in Emergency Department)
...Show More Authors

Background: Abdominal symptoms are possibly the most frequent of all symptoms encountered in surgical practice.  Pain is the most common of all abdominal symptoms.  Causes of acute abdominal pain include both medical and surgical. Most symptoms arise from intra-abdominal organs or systems while some may originate extra abdominally and are then referred to the abdomen. Medical causes of abdominal pain are encountered more frequently.

Objective: To study the causes of acute abdominal pain in patients attending emergency department in Al- Imamain Al- Kadhimain Medical City.

Type of the study: A prospective cross sectional study

Meth

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Coloproctology
Obesity and helicobacter pylori infection in adults with non specific colitis
...Show More Authors
Abstract<p> Background Non specific colitis is defined as inflammatory condition of the colon that when examined microscopically lacks any characteristic features of any specific form of colitis and is commonly seen in reports of colonoscopy biopsies. There are many factors that cause it like obesity and H pylori.</p><p> Aim of the study To determine the association of obesity and H pylori as contributory factors to this disease.</p><p> Patients and methods This is a case-controlled study was carried out in Al-Kindy College of Medicine from January 2017 to June 2018. Sixty individuals were included; forty of them had non specific colitis. The rest were hea</p> ... Show More
View Publication
Scopus (2)
Scopus Crossref
Publication Date
Sun Jan 01 2006
Journal Name
Journal Of Engineering
SELF ORGANIZING FUZZY CONTROLLER FOR A NON-LINEAR TIME VARYING SYSTEM
...Show More Authors

This paper proposes a self organizing fuzzy controller as an enhancement level of the fuzzy controller. The adjustment mechanism provides explicit adaptation to tune and update the position of the output membership functions of the fuzzy controller. Simulation results show that this controller is capable of controlling a non-linear time varying system so that the performance of the system improves so as to reach the desired state in a less number of samples.

Publication Date
Tue Dec 30 2014
Journal Name
International Journal Of Medicine And Pharmaceutical Sciences (ijmps)
YIELDS CALCULATIONS FOR POSITRON EMISSION TOMOGRAPHY (PET) FOR NON-STANDARD RADIONUCLIDE
...Show More Authors

The PET scans provide images that pinpoint the anatomic location of abnormal metabolic activity within the body. A radionuclide suitable for labeling a wide range of radiopharmaceuticals for positron emission tomography imaging is used also for local therapy of tumors. Among the possible methods for cyclotron production of radionuclide used in PET. We investigate the proton irradiation to produce the standard radionuclide (15O, 11C,1 3N, 18F) and some non-standard Radionuclide (76Br,124I,60Cu,66Ga,86Y and 89Zr). The total integral yield based on the main published and approved experimental results of excitation functions were calculated.

Preview PDF
Publication Date
Fri Apr 30 2010
Journal Name
Ibn Al-haitham Journal For Pure And Applied Sciences (ihjpas)
Biochemical Study on Splenectomy and Non Splenectomy Iraqi Major Thalassemic Patients
...Show More Authors

Preview PDF
Publication Date
Sun Jun 30 2013
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Studying the Factors Affecting the Drag Coefficient in Non- Newtonian Fluids
...Show More Authors

The aim of this research is to study the factors affecting drag coefficient (C d ) in
non-Newtonian fluids which are the rheological properties ,concentrations of non-
Newtonian fluids, particle shape, size and the density difference between particle and
fluid .Also this study shows drag coefficient (C d ) and particle Reynolds' number (Re
P ) relationship and the effect of rheological properties on this relationship.
An experimental apparatus was designed and built, which consists of Perspex pipe
of length of 160 cm. and inside diameter of 7.8 cm. to calculate the settling velocity,
also electronic circuit was designed to calculate the falling time of particles through
fluid.
Two types of solid particles were

... Show More
View Publication Preview PDF
Publication Date
Fri Aug 13 2021
Journal Name
Journal Européen Des Systèmes Automatisés
Proxy-based sliding mode vibration control with an adaptive approximation compensator for euler-bernoulli smart beams
...Show More Authors

Proxy-based sliding mode control PSMC is an improved version of PID control that combines the features of PID and sliding mode control SMC with continuously dynamic behaviour. However, the stability of the control architecture maybe not well addressed. Consequently, this work is focused on modification of the original version of the proxy-based sliding mode control PSMC by adding an adaptive approximation compensator AAC term for vibration control of an Euler-Bernoulli beam. The role of the AAC term is to compensate for unmodelled dynamics and make the stability proof more easily. The stability of the proposed control algorithm is systematically proved using Lyapunov theory. Multi-modal equation of motion is derived using the Galerkin metho

... Show More
Crossref (2)
Crossref