Wireless Body Area Sensor Network (WBASN) is gaining significant attention due to its applications in smart health offering cost-effective, efficient, ubiquitous, and unobtrusive telemedicine. WBASNs face challenges including interference, Quality of Service, transmit power, and resource constraints. Recognizing these challenges, this paper presents an energy and Quality of Service-aware routing algorithm. The proposed algorithm is based on each node's Collaboratively Evaluated Value (CEV) to select the most suitable cluster head (CH). The Collaborative Value (CV) is derived from three factors, the node's residual energy, the distance vector between nodes and personal device, and the sensor's density in each CH. The CEV algorithm operates in the following manner: CHs are dynamically selected in each transmission round based on the nodes' CVs. The algorithm considered the patient's condition classification to guarantee safety and attain a response speed appropriate for their current state. So, data is categorized into Very-Critical, Critical, and Normal data classes using the supervised learning vector quantization (LVQ) classifier. Very Critical data is sent to the emergency center to dispatch an ambulance, Critical data is transmitted to a doctor, and Normal data is sent to a data center. This methodology promotes efficient and reliable intra-network communication, ensuring prompt and precise data transmission, and reducing frequent recharging. Comparative analyses reveal that the proposed algorithm outperforms ERRS (Energy-Efficient and Reliable Routing Scheme) and LEACH (low energy adaptive clustering hierarchy) regarding network longevity by 27% and 33%, augmenting network stability by 12% and 45% over the aforementioned protocols, respectively. The performance was conducted in OMNeT++ simulator
Fusidic acid (FA) is a well-known pharmaceutical antibiotic used to treat dermal infections. This experiment aimed for developing a standardized HPLC protocol to determine the accurate concentration of fusidic acid in both non-ionic and cationic nano-emulsion based gels. For this purpose, a simple, precise, accurate approach was developed. A column with reversed-phase C18 (250 mm x 4.6 mm ID x 5 m) was utilized for the separation process. The main constituents of the HPLC mobile phase were composed of water: acetonitrile (1: 4); adjusted at pH 3.3. The flow rate was 1.0 mL/minute. The optimized wavelength was selected at 235 nm. This approach achieved strong linearity for alcoholic solutions of FA when loaded at a serial concentrati
... Show MoreThe performance analyses of 15 kWp (kW peak) Grid -Tied solar PV system (that considered first of its type) implemented at the Training and Energy Research Center Subsidiary of Iraqi Ministry of Electricity in Baghdad city has been achieved. The system consists of 72 modules arranged in 6 strings were each string contains 12 modules connected in series to increase the voltage output while these strings connected in parallel to increase the current output. According to the observed duration, the reference daily yields, array daily yields and final daily yields of this system were (5.9, 4.56, 4.4) kWh/kWp/day respectively. The energy yield was 1585 kWh/kWp/year while the annual total solar irradiation received by solar array system was 198
... Show MoreAbstract
The changes that happened in the environment of business have great effects upon organizations with different activities specially the banks which requires the existence of an able opinion resources can adapt with the changes . Accordingly importance put upon intellectual capital which become one of the basic resources for organizations and one of success and growth elements with the availability of expertise , skills and capability of making essential changes in different process due to the presentation of innovations and creations of the to support banks activities .Therefore the intellectual capital represents the more r
... Show MoreThis paper presents a numerical simulation of the flow around elliptic groynes by using CFD software. The flow was simulated in a flume with 4m long, 0.4m wide, and 0.175m high with a constant bed slope. Moreover, the first Groyne placed at 1m from the flow inlet with a constant the Groyne height of 10cm and a 1cm thickness, and the width of Groynes equals 7cm. A submergence ratio of the elliptic Groynes of 75% was assumed, corresponding to a discharge of 0.0057m3/sec. The CFD model showed a good ability to simulate the flow around Groynes with good accuracy. The results of CFD software showed that when using double elliptic Groy
... Show MoreThe research aims to identify the most important variables affecting shooting from jumping high and compare them for the two foot the weak and strong, where the researchers adopted the descriptive method, and the sample was chosen by the intentional method, which consists of (4) players from the Iraqi Sports Army Club, where these variables were studied and their impact on The accuracy of aiming at the two men, and the researchers concluded that most of the players have more accuracy in aiming at the strong leg than at the weak leg, which leads to the loss of many real opportunities during the match because of the players changing the situation or wasting the available opportunity when the position of correction is an opportunity for the w
... Show MoreAs the banking sector is a strong influence on the country's economic growth,The solid financial well-being of anybank does not mean only a guarantee for its investors, It is also important for both owners and workers and for theeconomy in all its joints.The elements of capital adequacy and quality of assets are important to the functioning of thebanking business.In this study, the research sample included four private banks. Quarterly data were used for the period(2011 - 2018).Moreover, data is also collected from articles, papers, the World Wide Web (the Internet) and specializedinternational journals.In this research, an effort was made to try to find out the effect of (the ratio of the capital owned todeposits on the value of the bank),
... Show MoreEMS in accordance with ISO 14001: 2015 is considered an entry point to reduce environmental impacts, especially the effects resulting from the oil industry, which is the main source of environmental pollution and waste of natural resources, since the second revision of the standard took place in September 2015. The problem of the research was manifested in the weakness in understanding the correct guidelines that must be followed in order to obtain and maintain the standard. The purpose of this research was to give a general picture of what is behind ISO14001:2015 and how it is possible to create a comprehensive base for understanding its application by seeking the gap between the actually achieved reality, standards requirements
... Show MoreThe deployment of UAVs is one of the key challenges in UAV-based communications while using UAVs for IoT applications. In this article, a new scheme for energy efficient data collection with a deadline time for the Internet of things (IoT) using the Unmanned Aerial Vehicles (UAV) is presented. We provided a new data collection method, which was set to collect IoT node data by providing an efficient deployment and mobility of multiple UAV, used to collect data from ground internet of things devices in a given deadline time. In the proposed method, data collection was done with minimum energy consumption of IoTs as well as UAVs. In order to find an optimal solution to this problem, we will first provide a mixed integer linear programming m
... Show MoreThe Main Outfall drain pumping station in Nassiriyah is an important part in operation system of the Main Outfall Drain (MOD) where it reduces the water levels in the U/S area of its and converted through Syphon freely under the Euphrates, its consists of several parts: U/S Basin, Station Building which contains 12 pumps, and Head Basin with Syphon, This station suffers from high levels especially in D/S area due to the current situation which is represented by establishing of dyke with pipes on MOD which located at 24 km from D/S of pumping station and Al-Khamisiyah Canal which located at 2.3 km from the U/S of dyke which feeds(Al Hammar Marsh) during drought season, several scenarios were adopted in order to expl
... Show More