Preferred Language
Articles
/
YBim3JYBVTCNdQwCuoek
Assessment of using different ozone-friendly R22 alternative refrigerants in residential air conditioners in a high-ambient temperature country
...Show More Authors
Abstract<p>The performance of a vapor compression refrigeration system (VCRS)-based residential air conditioner operating in a high-ambient temperature (HAT) country was investigated using six zero-ODP (ozone depletion potential) refrigerants as replacements to R22. The non-flammable alternative refrigerants considered in the present research were R134a, R404A, R407C, R410A, R448A, and R507A. Using the basic conservation laws, the VCRS was modeled during steady-state operation and solved using engineering equation solver (EES) software. Coefficient of performance (COP), pressures and temperatures at compressor suction and discharge, Global Warming Potential (GWP), critical pressure and temperature, compressor pressure ratio, volumetric cooling capacity (VCC) specific cooling capacity (SCC), and refrigeration effect were utilized as assessment criteria for the alternative refrigerants considered. From these refrigerants, the highest values of suction pressure, discharge temperature, and condenser pressure were attained by R410A. In addition, the discharge temperatures for all refrigerants, except R134a, were all higher than their corresponding critical values, causing a quicker drop in the VCRS’s performance. As an alternative refrigerant, R407C showed the highest SCC of 141.0 kJ/kg followed directly by 139.2 and 138.0 kJ/kg for R410A and R448A, respectively. A reverse trend was found for VCC with respective values of 4722 and 3775 kJ/m<sup>3</sup> for R410A and R448A. Lower volume flow rates and smaller-sized compressors are expected for higher VCC refrigerants. The same trend was found for the compressor’s specific work input and condenser’s specific heat transfer with values of (51.14, 46.82, and 45.38 kJ/kg) and (190.3, 187.8, and 183.4 kJ/kg) for R410A, R407C, and R448A, respectively. For applications in HAT countries, larger condenser’s specific heat transfer makes the refrigerant more applicable. Conversely, with respect to COP, refrigerant R134a with a value of 3.075 was the superior alternative followed by R448A and R407C with respective COPs of 3.042 and 3.011. Based on the overall assessment in terms of environmental obligation, COP, compressor input power, refrigerant flow rate required, and all the evaluations made in this research, refrigerant R448A was recommended as the most appropriate substitute to R22 which can effectively be used in residential air conditioners in a HAT country.</p>
Scopus Crossref
View Publication
Publication Date
Tue Dec 20 2022
Journal Name
2022 International Conference On Computer And Applications (icca)
Improve Data Mining Techniques with a High-Performance Cluster
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Wed Sep 20 2023
Journal Name
Journal Of Aeronautical Materials
The Effect of A Dry Training Program Using Aids On The Results Of Error Measures And The Effect Size On The Air Pistol Accuracy Of Correction
...Show More Authors

The world is keeping pace with evolution in all its fields as a result of scientists' pursuit of continuous scientific and technological development. This evolution included the sports field, which had a large space in the aspect of development and for all disciplines, Therefore, it's reflected today in what we see of records and advanced achievements in sporting events and activities. The development in the field of sports was the result of scientific research (Hussein and Jawad., 2022), where the interest in the training process has become one of the most important pillars of the development of achievement (Neamah and Altay., 2020). The shooting sport has also witnessed a remarkable development due to the diversity and development of its

... Show More
Publication Date
Sun Nov 01 2020
Journal Name
Journal Of Engineering
Agile manufacturing assessment model using multi-grade evaluation
...Show More Authors

In unpredicted industrial environment, being able to adapt quickly and effectively to the changing is key in gaining a competitive advantage in the global market. Agile manufacturing evolves new ways of running factories to react quickly and effectively to changing markets, driven by customized requirement. Agility in manufacturing can be successfully achieved via integration of information system, people, technologies, and business processes. This article presents the conceptual model of agility in three dimensions named: driving factor, enabling technologies and evaluation of agility in manufacturing system. The conceptual model was developed based on a review of the literature. Then, the paper demonstrates the agility

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Thu Dec 01 2016
Journal Name
2016 Asia-pacific Microwave Conference (apmc)
High selectivity microstrip bandpass filter using feedback CRLH-TL unit cell
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Mar 01 2015
Journal Name
Journal Of Engineering
Digital Orthophoto Production Using Close-Range Photographs for High Curved Objects
...Show More Authors

Orthophoto provides a significant alternative capability for the presentation of architectural or archaeological applications. Although orthophoto production from airphotography of high or lower altitudes is considered to be typical, the close range applications for the large-scale survey of statue or art masterpiece or any kind of monuments still contain a lot of interesting issues to be investigated.

In this paper a test was carried out for the production of large scale orthophoto of highly curved surface, using a statue constructed of some kind of stones. In this test we use stereo photographs to produce the orthophoto in stead of single photo and DTM, by applying the DLT mathematical relationship as base formula in differenti

... Show More
View Publication Preview PDF
Publication Date
Tue Jun 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Variation of non-diatomic algae in a martyr monument lake under different climate factors
...Show More Authors
Abstract<p>The current study was conducted in the environment of the Martyr Monument Lake in the city center of Baghdad during 2019 to monitor the impact of climatic conditions such as drought, water shortage, high temperatures in the environment of the city and the lack of water flow during the years 2015 to 2018 and their effects on some of the physical and chemical factors of water and the dynamics of the phytoplankton community in the lake environment. Heterogeneity of some studied environmental factors, including air and water temperature, permeability, water depth, pH, DO, BOD5, nutrients, nitrate, NO3, and phosphates were found. The results showed the effect of climate change and the pres</p> ... Show More
View Publication Preview PDF
Scopus (2)
Scopus Crossref
Publication Date
Mon Dec 20 2021
Journal Name
Baghdad Science Journal
Temperature Stress on Physiological and Morphological Traits in Rhizophora apiculata
...Show More Authors

Global warming has had considerable effects on vital ecosystems, which has also been caused by increased temperatures and CO2 that follow changes in different abiotic factors, which poses threats to mangrove forests environment. This research was conducted to examine the physiological and morphological characteristics of the Rhizophora apiculata mangrove regarding higher air temperature for the variety of tree species that respond to climate change. Seedlings were cultivated for three months in regulated growth chambers with three varying temperatures of 38°C, 21°C under CO2 at 450 ppm, and ambient CO2 concentration i.e., 450 ± 20 ppm under average temperature at 28°C as the control condition

... Show More
View Publication Preview PDF
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Wed Mar 16 2022
Journal Name
Journal Of Educational And Psychological Researches
The Effectiveness of a Selective Counseling Program in Modifying the Irrational Thoughts That Cause Anger in a Sample of Female Teachers in Different Educational Stages
...Show More Authors

The research seeks to identify the effectiveness of a selective program in modifying irrational thinking that causes anger among an important class of societies in general. namely teachers. Specifically female teachers because of the pressures they suffer because of the nature of this profession. It may develop into anger outburst, which may cause irrational thinking arose as a result of the different situations they are going through. The sample of the program consisted of (12) teachers in Egypt, from different educational sectors. The researcher intended to clarify the emotion of anger and the irrational thoughts associated with it and the contribution of the selective counseling program in modifying those irrational thinking. This was

... Show More
View Publication Preview PDF
Publication Date
Mon Nov 01 2021
Journal Name
2021 International Conference On Intelligent Technology, System And Service For Internet Of Everything (itss-ioe)
Application of MQ-Sensors to Indoor Air Quality Monitoring in Lab based on IoT
...Show More Authors

Scopus (11)
Crossref (9)
Scopus Crossref
Publication Date
Mon Jun 06 2022
Journal Name
International Journal Of Health Sciences
effect of a training curriculum for the development of some functional variables and the level of achievement in the effectiveness of air rifle shooting
...Show More Authors

There are significant differences between the pre and post-tests in favor of the post-test in the tests) stroke volume (S.V), cardiac thrust (C.O.P), left ventricular volume, maximum oxygen consumption Vo2max), which indicates the effect of the proposed training approach.There are significant differences between the pre and post-tests in favor of the post-test in the achievement level test with air rifle shooting for young female shooters, which indicates the effect of the proposed training curriculum.There are no significant differences between the pre and post-tests in the tests (heart rate (HR) before exercise, heart rate (HR) after exercise, systolic blood pressure rate before exercise, systolic blood pressure rate after exercis

... Show More
View Publication
Crossref