The performance of a vapor compression refrigeration system (VCRS)-based residential air conditioner operating in a high-ambient temperature (HAT) country was investigated using six zero-ODP (ozone depletion potential) refrigerants as replacements to R22. The non-flammable alternative refrigerants considered in the present research were R134a, R404A, R407C, R410A, R448A, and R507A. Using the basic conservation laws, the VCRS was modeled during steady-state operation and solved using engineering equation solver (EES) software. Coefficient of performance (COP), pressures and temperatures at compressor suction and discharge, Global Warming Potential (GWP), critical pressure and temperature, compressor pressure ratio, volumetric cooling capacity (VCC) specific cooling capacity (SCC), and refrigeration effect were utilized as assessment criteria for the alternative refrigerants considered. From these refrigerants, the highest values of suction pressure, discharge temperature, and condenser pressure were attained by R410A. In addition, the discharge temperatures for all refrigerants, except R134a, were all higher than their corresponding critical values, causing a quicker drop in the VCRS’s performance. As an alternative refrigerant, R407C showed the highest SCC of 141.0 kJ/kg followed directly by 139.2 and 138.0 kJ/kg for R410A and R448A, respectively. A reverse trend was found for VCC with respective values of 4722 and 3775 kJ/m3 for R410A and R448A. Lower volume flow rates and smaller-sized compressors are expected for higher VCC refrigerants. The same trend was found for the compressor’s specific work input and condenser’s specific heat transfer with values of (51.14, 46.82, and 45.38 kJ/kg) and (190.3, 187.8, and 183.4 kJ/kg) for R410A, R407C, and R448A, respectively. For applications in HAT countries, larger condenser’s specific heat transfer makes the refrigerant more applicable. Conversely, with respect to COP, refrigerant R134a with a value of 3.075 was the superior alternative followed by R448A and R407C with respective COPs of 3.042 and 3.011. Based on the overall assessment in terms of environmental obligation, COP, compressor input power, refrigerant flow rate required, and all the evaluations made in this research, refrigerant R448A was recommended as the most appropriate substitute to R22 which can effectively be used in residential air conditioners in a HAT country.
paper
O estudo destaca a necessidade crítica de se focar nas capacidades físicas, motoras e técnicas das jogadoras de esgrima, desenvolvendo e testando metodologias de treino modernas, baseadas na ciência, adaptadas às exigências específicas do desporto. O objetivo do estudo foi avaliar a eficácia do treino tridimensional visando melhorar as capacidades motoras e o desempenho técnico dos participantes. Recorrendo a um desenho experimental, o estudo envolveu a formação de grupos experimentais e de controlo. A amostra incluiu 16 esgrimistas da Faculdade Feminina de Educação Física e Ciências do Desporto. Após a exclusão de dois jogadores durante a fase exploratória, os restantes 14 foram divididos igualmente em grupos experimental
... Show MorePurpose: This research seeks to provide a point of view based on the creation of sustainable value to the customer of the banks in the context of total quality management and relationship marketing. It aims to develop a model to measure the value of sustainable customer peduncular under total quality management PAL (administrative leadership, involvement of employees, continuous improvement, process improvement, staff training), through the mediation of relationship marketing and objective dimensions (administrative leadership, involvement of employees, continuous improvement, improving processes , staff training), and to explore any of the variables and dimensions more influential in the creation of sustainable value to the cust
... Show MoreThe aim of this study was to provide an overall assessment to the efficiency of the Iraq stocks exchanges (ISE) through specifying well –known models .First, Fama's efficient market hypothesis as a contrary concept to the random walk hypothesis, was performed and it has been found that ISE follows the random process, so the price of the shares can't be predicated on the basis of past information. Second,we use a multifactor model, which so named multiple regression, to explore the link between ISE and the main economic indicators. our empirical analysis finds that every weak associations exists between major ISE measures and main economic indicators.
Karst aquifers in semi-arid regions are vital yet exceptionally vulnerable lifelines. This study investigates how tectonic, geomorphological, and climatic factors control the dynamics of karst springs in the El Menzel Causse (Middle Atlas, Morocco). Using an integrated approach that combines field investigations, remote sensing, and quantitative hydro-climatic analysis, we identify the mechanisms driving the system’s severe decline. Results indicated that the structural architecture of the major fault systems in the North Middle Atlas Fault (NMAF) and the Median Middle Atlas Fault (MMAF), governs the spatial distribution of more than 50 springs, which occur preferentially within highly permeable fault damage zones. However, the aquifer is