Preferred Language
Articles
/
YBim3JYBVTCNdQwCuoek
Assessment of using different ozone-friendly R22 alternative refrigerants in residential air conditioners in a high-ambient temperature country
...Show More Authors
Abstract<p>The performance of a vapor compression refrigeration system (VCRS)-based residential air conditioner operating in a high-ambient temperature (HAT) country was investigated using six zero-ODP (ozone depletion potential) refrigerants as replacements to R22. The non-flammable alternative refrigerants considered in the present research were R134a, R404A, R407C, R410A, R448A, and R507A. Using the basic conservation laws, the VCRS was modeled during steady-state operation and solved using engineering equation solver (EES) software. Coefficient of performance (COP), pressures and temperatures at compressor suction and discharge, Global Warming Potential (GWP), critical pressure and temperature, compressor pressure ratio, volumetric cooling capacity (VCC) specific cooling capacity (SCC), and refrigeration effect were utilized as assessment criteria for the alternative refrigerants considered. From these refrigerants, the highest values of suction pressure, discharge temperature, and condenser pressure were attained by R410A. In addition, the discharge temperatures for all refrigerants, except R134a, were all higher than their corresponding critical values, causing a quicker drop in the VCRS’s performance. As an alternative refrigerant, R407C showed the highest SCC of 141.0 kJ/kg followed directly by 139.2 and 138.0 kJ/kg for R410A and R448A, respectively. A reverse trend was found for VCC with respective values of 4722 and 3775 kJ/m<sup>3</sup> for R410A and R448A. Lower volume flow rates and smaller-sized compressors are expected for higher VCC refrigerants. The same trend was found for the compressor’s specific work input and condenser’s specific heat transfer with values of (51.14, 46.82, and 45.38 kJ/kg) and (190.3, 187.8, and 183.4 kJ/kg) for R410A, R407C, and R448A, respectively. For applications in HAT countries, larger condenser’s specific heat transfer makes the refrigerant more applicable. Conversely, with respect to COP, refrigerant R134a with a value of 3.075 was the superior alternative followed by R448A and R407C with respective COPs of 3.042 and 3.011. Based on the overall assessment in terms of environmental obligation, COP, compressor input power, refrigerant flow rate required, and all the evaluations made in this research, refrigerant R448A was recommended as the most appropriate substitute to R22 which can effectively be used in residential air conditioners in a HAT country.</p>
Scopus Crossref
View Publication
Publication Date
Fri Apr 18 2014
Journal Name
Journal Of Advances In Chemistry
Anastatica Hierochuntica L. Used As an Alternative of Conjugated Estrogen (Premarin) in Rabbit Females
...Show More Authors

There are risks and benefits with all medicines and estrogen replacement is no exception. In fact, estrogen replacement is one of the most controversial topics in Endocrinology. Anastatica hierochuntica L. is a popular treatment for the management of female reproductive disorders. The present research highlights the effect of aqueous extract of plant against conjugated estrogen(Premarin) in rabbits. Femal oryciolagus cuniculus rabbits were divided into four groups: the 1 st group, rabbits were orally administered (using a feeding solution )with daily dose(5 mL distilled water)for two months, the 2nd group, the rabbits were treated with conjugated estrogen (50 µg/kg b.w, body weight )for one month. The 3rd group, the rabbits were treated w

... Show More
Publication Date
Fri Apr 18 2014
Journal Name
Journal Of Advances In Chemistry
Anastatica Hierochuntica L. Used As an Alternative of Conjugated Estrogen (Premarin) in Rabbit Females
...Show More Authors

Anastatica Hierochuntica L. Used As an Alternative of Conjugated Estrogen (Premarin) in Rabbit Females

Publication Date
Mon Jan 21 2019
Journal Name
International Journal Of Pharmaceutical Quality Assurance
Genetic Assessment of Antibiotic Resistance in Salmonella Enteric a Serovar Typhi in Kirkuk Province
...Show More Authors

Around fifty isolates of Salmonella enterica serovar Typhi were isolated from blood specimens of patients referring to several hospitals in Kirkuk province, Iraq. The results revealed that all isolates developed resistance to trimethoprim-sulfamethoxazole and chloramphenicol. However, neither sul2 nor tem genes were detected. Moreover, only ten isolates were positive for catP. Our data suggested participation of other genes or mechanisms allow these multidrug isolates to resist the antibiotics in question.

Publication Date
Tue Sep 11 2018
Journal Name
Iraqi Journal Of Physics
Analytical study of high absorption region of the absorption edge of a-Si:H using nonlinear regression method
...Show More Authors

This research is concerned with the re-analysis of optical data (the imaginary part of the dielectric function as a function of photon energy E) of a-Si:H films prepared by Jackson et al. and Ferlauto et al. through using nonlinear regression fitting we estimated the optical energy gap and the deviation from the Tauc model by considering the parameter of energy photon-dependence of the momentum matrix element of the p as a free parameter by assuming that density of states distribution to be a square root function. It is observed for films prepared by Jackson et al. that the value of the parameter p for the photon energy range is is close to the value assumed by the Cody model and the optical gap energy is which is also close to the value

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Journal Of Engineering
A Mathematical Model of a Thermally Activated Roof (TAR) Cooling System Using a Simplified RC-Thermal Model with Time Dependent Supply Water Temperature
...Show More Authors

This paper presents a computer simulation model of a thermally activated roof (TAR) to cool a room using cool water from a wet cooling tower. Modeling was achieved using a simplified 1-D resistance-capacitance thermal network (RC model) for an infinite slab. Heat transfer from the cooling pipe network was treated as 2-D heat flow. Only a limited number of nodes were required to obtain reliable results. The use of 6th order RC-thermal model produced a set of ordinary differential equations that were solved using MATLAB - R2012a. The computer program was written to cover all possible initial conditions, material properties, TAR system geometry and hourly solar radiation. The cool water supply was considered time

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 30 2004
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Evaluation of Solid-Solid Mixing in an Air Fluidized Bed
...Show More Authors

View Publication Preview PDF
Publication Date
Mon Oct 01 2018
Journal Name
Journal Of Engineering
Experimental Study of Hybrid Solar Air Conditioning System in Iraq
...Show More Authors

In this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average p

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Wed Jan 01 2014
Journal Name
International Journal Of Innovative Research In Science, Engineering And Technology
EFFECT AMBIENT OXIDATION ON STRUCTURAL AND OPTICAL PROPERTIES OF COPPER OXIDE THIN FILMS
...Show More Authors

The structural, optical properties of copper oxide thin films ( CuO) thin films which have been prepared by thermal oxidation with exist air once and oxygen another have been studied. Structural analysis results of Cu thin films demonstrate that the single phase of Cu with high a crystalline structure with a preferred orientation (111). X-ray diffraction results confirm the formation of pure (CuO) phase in both methods of preparation. The optical constant are investigated and calculated such as absorption coefficient, refractive index, extinction coefficient and the dielectric constants for the wavelengths in the range (300-1100) nm.

Preview PDF
Publication Date
Thu Aug 04 2022
Journal Name
Journal Of Nanomaterials
Thermal Management of the Melting Process in a Latent Heat Triplex Tube Storage System Using Different Configurations of Frustum Tubes
...Show More Authors

In this study, the energy charging mechanism is mathematically modeled to determine the impact of design modifications on the thermofluidic behavior of a phase change material (PCM) filled in a triplex tube containment geometry. The surface area of the middle tube, where the PCM is placed, is supported by single or multi-internal frustum tubes in vertical triplex tubes to increase the performance of the heating and cooling of the system. In addition to the ordinary straight triplex tubes, three more scenarios are considered: (1) changing the middle tube to the frustum tube, (2) changing the inner tube to the frustum tube, and (3) changing both the internal and central tubes to the frustum tubes. The impact of adopting the tube desig

... Show More
View Publication
Scopus (49)
Crossref (44)
Scopus Clarivate Crossref
Publication Date
Wed Oct 12 2011
Journal Name
Journal Of Liquid Chromatography &amp; Related Technologies
RAPID DETERMINATION OF SPHINGANINE AND SPHINGOSINE IN URINE BY HIGH PERFORMANCE LIQUID CHROMATOGRAPHY USING MONOLITHIC COLUMN
...Show More Authors

A rapid high performance liquid chromatography method for the determination of sphinganine (Sa) and sphingosine (So) in urine samples by employing a silica-based monolithic column is described. The samples were first extracted using ethyl acetate and derivatized using ortho-phthaldialdehyde in the presence of 2-mercaptoethanol. C20 sphinganine was used as internal standard. Under the optimized conditions, separation was achieved using a mixture of methanol:water (93:7, v/v), column temperature at 30°C, flow rate of 1 mL min−1, and an injection volume of 10 μL. Good linearity was obtained for Sa and So over the concentration range 20–500 ng mL−1(correlation coefficients ≥0.9978). The detection limits were 0.45 ng mL−1 for Sa and

... Show More
View Publication
Scopus Clarivate Crossref