In this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies
... Show MoreThis research paper is about thevariationin the degree of Continentality climate of the
Iraq during (40) years for a number of climate station. Using Poresof formula, it is found out
that the climate of Iraq ranges between extreme Continentality and very extreme
Continentality, and that the Continentality degree is characterized with extreme frequency
from one year to another. In certain years, the degree of climate Continentality decreases
while in other years it rises in such a way that there is no similarity in the Continental degree
from one year to another for the same station.
As for the general trend of the degree of Continentality, the last years had noticed
special variations, which are divided in to thre
The paper presents mainly the dynamic response of an angle ply composite laminated plates subjected to thermo-mechanical loading. The response are analyzed by analytically using Newmark direct integration method with Navier solution, numerically by ANSYS. The experimental investigation is to fabricate the laminates and to find mechanical and thermal properties of glass-polyester such as longitudinal, transverse young modulus, shear modulus, longitudinal and transverse thermal expansion. Present of temperature could increase dynamic response of plate also depending on lamination angle, type of mechanical load and the value of temperature.
The earth's surface comprises different kinds of land cover, water resources, and soil, which create environmental factors for varied animals, plants, and humans. Knowing the significant effects of land cover is crucial for long-term development, climate change modeling, and preserving ecosystems. In this research, the Google Earth Engine platform and freely available Landsat imagery were used to investigate the impact of the expansion and degradation in urbanized areas, watersheds, and vegetative cover on the land surface temperature in Baghdad from 2004 to 2021. Land cover indices such as the Normalized Difference Vegetation Index, Normalized Difference Water Index, and Normalized Difference Built-up Index (NDVI, NDWI, an
... Show MoreYoung people represent the power and cornerstone of societies and their superiority is linked to their well-being. Their empowerment is as essential as the heart to the body, if it is corrupt, then the whole body is corrupt, and vice versa. The exposure to extremism and pressure from their families leads to violent acts and crimes for obtaining money through unknown organized bodies. This will drive them to fail in their life in an attempt to fulfill their most basic needs, which they have been deprived of by their families, the government, and other institutions. Therefore, governments should provide job opportunities for young people and provide entertainment centers, sports clubs, and family education centers that raise awareness of s
... Show MoreAn energy and exergy thermodynamic analysis using EES program was done for a domestic refrigerator working with R-134a using vapor compression refrigeration cycle. The analysis deals with the system component, i.e. compressor, condenser, evaporator and the expansion device. The analysis depends on the entropy generation minimization approach to improve the refrigerator performance by exploring the optimum design points. These design points were derived from three different theories governing the entropy generation minimization using exergy analyzing method. These theories were first applied to find the optimum balance between the hot inner condenser area and the cold inner evaporator area of the refrigerator and between
... Show MoreBN Rashid
A total of 228 domestic and wild animals, including sheep, goats, cows, buffaloes, camels, horses, donkeys, dogs, cats, wild hares, Asiatic jackals, and red foxes were examined for ixodid ticks in the central region of Iraq. Nine species of ixodid ticks belong to two genera namely Hyalomma anatolicum Koch, 1844, H. excavatum Koch, 1844, H. turanicum Pomerantsef, 1946, H. scupense Delpy, 1946, H. dromedarii Koch, 1844, H. schulzei Olenev, 1931, Rhipicephalus annulatus (Say, 1821), R. turanicus Pomerantsef & al., 1940 and R. leporis Pomerantsef, 1946 were recovered. Their distribution among hosts and infestation rates were di
... Show MoreSloped solar chimney system is a solar chimney power plant with a sloped collector. Practically, the sloped collector can function as a chimney, then the chimney height can be reduced and the construction cost would be reduced.The continuity, Naver-stockes, energy and radiation transfer equations have been solved and carried out by Fluent software. The governing equations are solved for incompressible, 3-D, steady, turbulent standard model with Boussiuesq approximation to develop for the sloped solar chimney system in this study and evaluate the performance of solar chimney power plant in Baghdad city of Iraq numerically by Fluent (14) software with orking conditions such as solar radiation intensity (30
... Show MoreIn this paper, an experimental study of the thermal performance for hybrid solar air conditioning system was carried out, to investigate system suitability for the hot climate in Iraq. The system consists of vapor compression unit combined with evacuated tube solar collector and liquid storage tank. A three-way valve was installed after the compressor to control the direction flow of the refrigerant, either to the storage tank or directly to the condenser. The performance parameters were collected by data logger to display and record in the computer by using LabVIEW software. The results show that the average coefficient of performance of hybrid solar air conditioning system (R=1) was about 2.42 to 2.77 and the average p
... Show More