With the increasing intensity of the ecological and environmental problems and the scarcity of fresh water, this paper was introduced to investigate the ability to use treated wastewater as a cooling media via studying its behavior throughout a cooling tower. The simultaneous transfer of heat and mass from the treated wastewater to air over splash-fill packing arranged in a zigzag manner was studied. The characteristic of the cooling tower, the outlet water temperature, and the rejected heat were investigated as the water-to-air ratio and inlet water temperature were varied. The core results show that the cooling tower of the tower decreases with increasing water-to-air ratio, and increases with the raise of inlet water temperature. Moreover, relationships between cooling tower and water-to-air ratio were obtained for each. It was also observed that the outlet water temperature increases gradually with increasing water-to-air ratio and temperature, and the difference between the inlet and outlet temperature becomes larger by increasing the inlet temperature. The heat rejected value increases with increasing the air-flow rate, water flow rate, and temperature. This study revealed that cooling tower of splash fills arranged in a zigzag manner was higher compared to other types of packing. In the same time, the results for the treated wastewater and fresh water were very close that gives approximate behavior, and this can save a huge amount of fresh water for other humanistic utilization, along with taking benefit from the treatment process of wastewater instead of through it into the aquatic systems.
Copper electrodeposition by electrorefining process in acidic sulfate media contains 40 g/l of cupric ions and 160 g/l of sulfuric acid was achieved to study the influence of the operating parameters on cathode purity, surface morphology, deposition rate, current efficiency and power consumption. These operating parameters and there ranges are: current density 200, 300 and 400 A/m2, electrolyte temperature 35, 50 and 65 oC, electrodes spacing 15, 30 and 45 mm and electrolyte residence time 6, 4 and 2 h were utilized. XRF, SEM and EDX analyses were attained to clarify the properties of the produced cathode.
: In this study, a linear synchronous machine is compared with a linear transverse flux machine. Both machines have been designed and built with the intention of being used as the power take off in a free piston engine. As both topologies are cylindrical, it is not possible to construct either using just flat laminations and so alternative methods are described and demonstrated. Despite the difference in topology and specification, the machines are compared on a common base in terms of rated force and suitability for use as a generator. Experience gained during the manufacture of two prototypes is described.
Biaxial hollow slab is a reinforced concrete slab system with a grid of internal spherical voids included to reduce the self-weight. This paper presents an experimental study of behavior of one-way prestressed concrete bubbled slabs. Twelve full-scale one-way concrete slabs of (3000mm) length with rectangular cross-sectional area of (460mm) width and (150mm) depth. Different parameters like type of specimen (solid or bubbled slabs), type of reinforcement (normal or prestress), range of PPR and diameter of plastic spheres (100 or 120mm) are considered. Due to the using of prestressing force in bubbled slabs (with ratio of plastic sphere diameter D to slab thickness H, D/H=0.67), the specimens showed an increase in ultimat
... Show MoreOne of the challenging issues encountered during drilling operations is the lost circulation. Numerous issues might arise because of losses, such as wasting of time and higher drilling cost. Several types of lost circulation materials have been developed and are being used to limit mud losses and avoid associated issues. Each solution has benefits and drawbacks.
In this study, a core flooding test was performed to study the effectiveness of polyacrylamide (PAM) granular gel on the reduction of the circulation lost. One common type of fracture characteristic is fractures with tips, commonly known as partially open fracture (POF). However, PAM gel therapy in POFs received little attention in prior research. Models of partly open fra
... Show MoreIn the current study, CuAl0.7In0.3Te2 thin films with 400 nm thickness were deposited on glass substrates using thermal evaporation technique. The films were annealed at various annealing temperatures of (473,573,673 and 773) K. Furthermore, the films were characterized by X-ray Diffraction spectroscopy (XRD), field emission scanning electron microscopy (FESEM), atomic force microscopy (AFM), and Ultra violet-visible (UV–vis). XRD patterns confirm that the films exhibit chalcopyrite structure and the predominant diffraction peak is oriented at (112). The grain size and surface roughness of the annealed films have been reported. Optical properties for the synthesized films including, absorbance, transmittance, dielectric constant, and refr
... Show MoreComplexes of Cr+3, Ni+2 and Cu+2 with the ligand 2-(p- nitrobenzoyl) thiobenzimidazol) (L) were prepared and characterized by FT-IR ,UV-Visible, TG analysis ,Atomic absorption spectroscopy , Molar conductivity and magnetic moments measurements .The general formula has been suggested for all the prepared complexes [Cr(L)2Cl2]Cl.4H2O, [Ni(L)2(H2O)2]Cl2.2H2O and [Cu(L)2(H2O)2]Cl2.2C2H5OH to be an octahedral geometry. A theoretical treatment of these compounds in gas phase was done using HyperChem.8.7 program. Semi –empirical PM3 method was performed to evaluate the ∆H° ƒ, ∆ Eb and ∆ET for all compounds, also vibration frequencies, electronic spectra and electrostatic potential HOMO and LUMO energies for the ligand was estimated to de
... Show MoreThe manifestations of climate change are increasing with the days: sudden rains and floods, lakes that evaporate, rivers that experience unprecedentedly low water levels, and successive droughts such as the Tigris, Euphrates, Rhine, and Lape rivers. At the same time, energy consumption is increasing, and there is no way to stop the warming of the Earth's atmosphere despite the many conferences and growing interest in environmental problems. An aspect that has not received sufficient attention is the tremendous heat produced by human activities. This work links four elements in the built environment that are known for their high energy consumption (houses, supermarkets, greenhouses, and asphalt roads) according t