Preferred Language
Articles
/
XRaJGIcBVTCNdQwCdza0
The Effect of Weighting Materials on the Rheological Properties of Iraqi and Commercial Bentonite in Direct Emulsion
...Show More Authors

Numerous drilling additives and materials are used continuously because they are necessary to support and give the required properties of the drilling fluid so that to ensure the stability of the borehole. This paper aspires to evaluate the rheological properties of bentonite (montmorillonite) Trefawey as an alternative to using commercial bentonite. Monitoring and evaluating of the rheological and filtration properties were prepared. This exertion aims to focus on the effect of hematite, and barite on the rheological properties of the three aforementioned bentonite types. An improvement in the rheological properties of bentonite (montmorillonite). Trefawey was observed after adding the previous heavy materials. Hematite has by some means better ability to improve rheological properties compared to other heavy materials. The emulsifying agent used was Carboxyl Methyl Cellulose (HOCH2COONA), as it has provided excellent results parallel to the lignite. The rheological properties of bentonite (montmorillonite) Trefawey are enhanced by doubling the amount of carboxyl methyl cellulose (HOCH2COONA). The results have proved that the use of weighting materials and emulsifying agent affected the rheological properties of bentonite (montmorillonite) Trefawey in a direct emulsion. The results have shown that it is more appropriate to use carboxyl methyl cellulose as an emulsifying agent to prepare a direct emulsion than bentonite (montmorillonite) Trefawey due to its excellent effect in improving the rheological properties of bentonite (montmorillonite) Trefawey. And it can be said that this effort has succeeded in studying two effects simultaneously. In other words, both heavy substances and emulsifying agent have effects on bentonite (montmorillonite) Trefawey, in order to obtain a stable emulsion and a clearer view of the behavior of Iraqi bentonite. The above effort has focused on making bentonite (montmorillonite) Trefawey suitable for the nature of geological layers such as oil shale, limestone and sandstone. This means preparing drilling fluid using bentonite (montmorillonite) Trefawey to drill the above structures. The study has concluded that it is better to use bentonite (montmorillonite) Trefawey in preparing direct oil emulsions as a stable and successful alternative of imported bentonite.

Crossref
View Publication
Publication Date
Sat Feb 28 2026
Journal Name
Journal Of Physical Education
The Effect of Compound Physical and Skill Exercises on the Development of Explosive Strength and Some Offensive Skills for Basketball Players U18
...Show More Authors

View Publication
Publication Date
Wed Sep 01 2021
Journal Name
Baghdad Science Journal
Concentrations and Radiation Hazard Indices of Naturally Radioactive Materials for Flour Samples in Baghdad Markets
...Show More Authors

In the present work, Uranium (238U), Thorium (232Th) and Potassium (40K) specific activity concentration in (Bq/kg) was measured in five different types for wheat flours that are available in the Iraqi markets. The gamma spectrometry method with an NaI (Tl) detector has been used for radiometric measurements. Calculations of radium equivalent activity, annual effective dose equivalent, external hazard index (Hex), internal hazard index (Hin), representing gamma index and gamma dose rate in all  flour samples were 17.98132 Bq/kg, 0.0100334, 0.04502, 0.04857, 0.06872, 0.125883 and 8.181244 respectively. It is found that the average of specific activity concentration of wheat flour sam

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Thu Mar 30 2017
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Evaluation of the Role of Interleukein-2 and Interleukein-4 in the Immunopathogenesis of Steroid Therapy Resistance in Iraqi Asthmatic Patients
...Show More Authors

Interleukins (IL-2 and IL-4) are increased in asthmatics and were reported to induce resistance to steroid therapy in some patients who fail to get benefit from glucocorticoids when used in full dose and for long period of time. In this context, the present study was conducted on Iraqi patients to provide additional laboratory mean, beside the clinical diagnosis, for the decision whether the asthma is steroid sensitive or resistant by monitoring the level of immunoglobulins, complement proteins and interleukins among asthmatic patients (steroid sensitive or resistant) and the possible contribution of other factors like age, sex and environments in the development of steroid resistance. A total number of 55 asthmatics and 28 normal subjec

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Mar 03 2022
Journal Name
Arabian Journal For Science And Engineering
Experimental Study of Cuttings Transport Efficiency of Low Solid Bentonite Drilling Fluids Modified by Cellulose Nanoparticles
...Show More Authors

Advancements in horizontal drilling technologies are utilized to develop unconventional resources, where reservoir temperatures and pressures are very high. However, the flocculation of bentonite in traditional fluids at high temperature and high pressure (HTHP) environments can lower cuttings transportation efficiency and even result in problems such as stuck pipe, decreased rate of penetration (ROP), accelerated bit wear, high torque, and drag on the drill string, and formation damage. The major purpose of the present research is to investigate the performance of low bentonite content water-based fluids for the hole cleaning operation in horizontal drilling processes. Low bentonite content water-based drilling fluids were formulated by re

... Show More
Crossref (7)
Crossref
Publication Date
Mon Jan 01 2024
Journal Name
2nd International Conference For Engineering Sciences And Information Technology (esit 2022): Esit2022 Conference Proceedings
Determination of moisture content in some materials using linear attenuation coefficient
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sun Dec 01 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Effect of existing deposit facilities on the quality of bank liquidity: Applied research in the Central Bank of Iraq for the period (2010 - 2017)
...Show More Authors

The research aims at showing the effectiveness of the existing deposit facilities in the liquidity of the Iraqi banking system for the period 2010/2017. The problem of research indicates that the Iraqi banking system enjoys high liquidity levels exceeding the standard rate set by the Central Bank of Iraq amounting to 30% For an appropriate level of liquidity remains a major challenge to the management of the bank because it is a trade-off between profitability and liquidity, and also indicates the existence of funds disabled and not available for credit and investment opportunities, and based on the research hypothesis:

The existence of a significant effect of the deposit facilities existing in the liquidity of the Iraqi banking

... Show More
View Publication Preview PDF
Publication Date
Sun Apr 30 2017
Journal Name
Journal Of Engineering
Study the effect of microbial factor on the qualities and characteristics of Novolak composite material, reinforced glass fibers / Asbestos fibers.
...Show More Authors

The study was reflection of the impact of the widespread use of polymer Novolak composite reinforced  Glass fiber and Asbestos fiber once again with weight fraction 60% on the physical properties, which included (Hardness, Compressive deformation, compressive modulus of elasticity, Flexural modulus of elasticity, Resilience modulus, the maximum of Flexural strength, Flexural strain energy and Shear strength inner layers); it is known how much important the media as a source of bacterial contamination, which contributes directly or indirectly in the process of aging of these materials. These Novolak composite reinforced,  prepared by weight fraction of (10%) and (14%) of the Hexamethylene-tetraamine (HMTA) hardener material. It

... Show More
View Publication Preview PDF
Publication Date
Mon Dec 20 2021
Journal Name
Journal Of Craniofacial Surgery
The Effect of Bone Density Measured by Cone Beam Computed Tomography and Implant Dimensions on the Stability of Dental Implants
...Show More Authors

Abstract: The aim of this study was to evaluate the effect of bone density value in Hounsfield unit derived from cone beam computed tomography (CBCT), and implant dimensions in relation to implant stability parameters namely the resonance frequency analysis and the insertion torque (IT) value. It included 24 patients who received 42 dental implants (DI). The bone density of the planned implant site was preoperatively measured using cone beam computed tomography. The implant stability was measured using Osstell implant stability quotient (ISQ). The ISQ values were recorded immediately postoperatively and after 16 weeks. The IT value was categorized as 35 N/cm or > 35 N/cm. The mean (standard deviation) primary stability was 79.58 (5.27) ISQ,

... Show More
View Publication
Scopus (14)
Crossref (18)
Scopus Clarivate Crossref
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center of t

... Show More
View Publication Preview PDF
Scopus (14)
Crossref (13)
Scopus Crossref
Publication Date
Fri Jun 11 2021
Journal Name
Journal Of Baghdad College Of Dentistry
The effect of composite bonding spot size and location on the performance of poly-ether-ether-ketone (PEEK) retainer wires
...Show More Authors

Background: Poly-ether-ether-ketone(PEEK) has been introduced to many dental fields. Recently it was tested as a retainer wire‎ following orthodontic treatment. This study aimed to investigate the effect of changing the bonding spot size and location on the performance of PEEK retainer wires. Methods: A biomechanical study involving four three-dimensional finite element models was performed. The basic model was with a 0.8 mm cylindrical cross-section PEEK wire, bonded at the center of the lingual surface of the mandibular incisors with 4 mm in diameter composite spots. Two other models were designed with 3 mm and 5 mm composite sizes. The last model was created with the composite bonding spot of the canine away from the center

... Show More
Scopus (14)
Crossref (13)
Scopus Crossref