Aim: To evaluate the side effects of Tamsulosin hydrochloride in fertility of experimental rats. Materials and methods: three groups of mice were used. First and second groups were injected [intraperitoneal (I.P.)] daily for 42 with 8 and 16 µg /kg mouse body weight (kg.b.wt) of Tamsulosin hydrochloride, respectively. Third group was injected with PBS (control). Several biological and histopathological studies were conducted on rat groups. Results: Significant decrease in number, motility and viability of epididymal sperm post injection with 16 µg /kg.b.wt, while injection with 8 µg /kg.b.wt reduced significantly, percentage of viability of sperm as compared with the control group. High percentage of abnormal sperm was observed in mice t
... Show MoreIn this paper a dynamic behavior and control of a jacketed continuous stirred tank reactor (CSTR) is developed using different control strategies, conventional feedback control (PI and PID), and neural network (NARMA-L2, and NN Predictive) control. The dynamic model for CSTR process is described by a first order lag system with dead time.
The optimum tuning of control parameters are found by two different methods; Frequency Analysis Curve method (Bode diagram) and Process Reaction Curve using the mean of Square Error (MSE) method. It is found that the Process Reaction Curve method is better than the Frequency Analysis Curve method and PID feedback controller is better than PI feedback controller.
The results s
... Show MoreElbow stiffness is hard to treat and commonly resulted from trauma or degenerative arthritis. This study aimed to demonstrate the effectiveness of using ultrasound therapy in management of stiff elbow joint resulted from several etiological factors. A total number of 42 patients (35 male and 7 female) allocated randomly from the Department of Physiotherapy at Al-yarmouk Teaching Hospital during 2013. Each patient examined physically by physiotherapist taking in consideration the measurement of the joint movement angle using goniometer in flexion and the extension, and the pain score using visual analogue scale (VAS). Ultrasound therapy initiated thrice weekly for two weeks. At the time of entry, the means degree of flexion and extension
... Show MoreIn this work, the antibacterial effectiveness of face masks made from polypropylene, against Candida albicans and Pseudomonas aeruginosa pathogenic was improved by soaking in gold nanoparticles suspension prepared by a one-step precipitation method. The fabricated nanoparticles at different concentrations were characterized by UV-visible absorption and showed a broad surface Plasmon band at around 520 nm. The FE-SEM images showed the polypropylene fibres highly attached with the spherical AuNPs of diameters around 25 nm over the surfaces of the soaked fibres. The Fourier Transform Infrared Spectroscopy (FTIR) of pure and treated face masks in AuNPs conform to the characteristics bands for the polypropylene bands. There are some differences
... Show MoreThis research describes the design & implementation of frequency synthesizer using single loop Phase lock loop with the following specifications: Frequency range (1.5 – 2.75) GHz,Step size (1 MHz), Switching time 36.4 µs, & phase noise @10 kHz = -92dBc & spurious -100 dBc
The development in I.C. technology provide the simplicity in the design of frequency synthesizer because it implements the phase frequency detector(PFD) , prescalar & reference divider in single chip. Therefore our system consists of a single chip contains (low phase noise PFD, charge pump, prescalar & reference divider), voltage controlled oscillator , loop filter & reference oscillator. The single chip
... Show More