In this work, effects of using different evaporative cooling pads (ECPs) on the energetic and exergetic efficiency of a direct evaporative air cooler (DEAC) have been theoretically and experimentally investigated. Three types of ECPs were used, i.e., honeycomb cellulose cooler pad (HCCP), shading-cloth cooler pad (SCCP), and aspen wood wool cooler pad (AWWCP). For SCCP and AWWCP, a 3-cm pad thickness was used, while for the HCCP, three different values of pad thickness were used, i.e., 3, 5, and 7 cm. Tests were carried out using air velocities of 8, 14, and 19 m/s, measured at the DEAC outlet. Engineering equation solver (EES) used for performing the required calculations of the various parameters affecting the thermal performance of the DEAC, i.e., dry bulb temperature at exit (Tdb), relative humidity at exit (RHo), mass of water evaporated, saturation efficiency, energetic efficiency (ηen), exergetic efficiency (ηex), and the overall exergetic efficiency (ηex). Results showed the great effectiveness of HCCP compared to the other studied types. HCCP showed the highest energetic efficiency reached 103 % for 3 cm thickness of the ECP, and the highest exergetic efficiency of about 19 %.
Objective: Assess type 2 diabetic patients’ knowledge regarding preventive measures of diabetic foot. Find out the relationship between of type 2 diabetic patients’ knowledge regarding preventive measures of diabetic foot with certain sociodemographic characteristics
Methodology: A descriptive study was carried out from (2nd January 2022 to 26th March 2022). A non –probability (purposive) sample of (60) adult patients who are diagnosed with type2 diabetes mellitus these patients have met the study criteria which was selected from Imam AL-Hussein Medical-City. The study instrument consist of two section: (Demographic Information Sheet, and Foot Care Outcome Expectation
... Show MoreA thin film of (SnSe) and SnSe:Cu with various Cu ratio (0,3,5 and 7)% have been prepared by thermal evaporation technique with thickness 400±20 nm on glass substrate at (R.T). The effect of Cu dopants concentration on the structural, morphological, optical and electrical properties of (SnSe) Nano crystalline thin films was explored by using X-ray diffraction (XRD), scanning electron microscopy (SEM), atomic force microscopy (AFM), energy dispersive spectroscopy (EDS), UV–Vis absorption spectroscopy and Hall Effect measurement respectively. X-ray diffraction analysis reveal the polycrystalline nature of the all films deposited with orthorhombic structure which possess a preferred orientation along the (111) plane. The crystalline sizes o
... Show MoreThe laminar fluid flow of water through the annulus duct was investigated numerically by ANSYS fluent version 15.0 with height (2.5, 5, 7.5) cm and constant length (L=60cm). With constant heat flux applied to the outer duct. The heat flux at the range (500,1000,1500,2000) w/m2 and Reynolds number values were ≤ 2300. The problem was 2-D investigated. Results revealed that Nusselt number decrease and the wall temperature increase with the increase of heat flux. Also, the average Nusselt number increase as Re increases. And as the height of the annulus increase, the values of the temperature and the local and average Nusselt number increase.
The interlaminar fracture toughness of polymer blends reinforced by glass fiber has
been investigated. Epoxy (EP), unsaturated polyester(UPE), polystyrene (PS),
polyurethane (PU) and their blends with different ratios (10%PS/90%EP),
(20%PS/80%EP), (20%PU/80%EP) and (20%PU/80%UPE) were chosen as a matrices A
sheet of composites were prepared using hand lay -up method, these sheet were cut as the
double cantilever beam (DCB) specimen to determine interlaminar fracture toughness of
these composites .Its found that, blending of EP,UPE with 20% of PU will improve the
interlaminar fracture toughness ,but the adding of 10% PS, 20%PS to EP will decrease
the interlaminar toughness of these composites.
Purpose: To identify the risk factors of urinary incontinency for menopausal women.
Methodology: A descriptive analytic study was conducted to identify the risk factor for urinary incontinency
and selected non-probability sample (purposive sample) from (200) menopausal women (45-65) who have
urinary incontinence as visitors and caregiver women who attend at Hila surgical teaching hospital during the
period 1/11/2010-30/3/2011. Questionnaire format used for data collection was designed and constructed
after reviewing related literatures and previous studies and consists of the following variables: Demographic
and reproductive characteristics of menopausal women who suffers from urinary incontinence
Results: The study