Preferred Language
Articles
/
WRcoCpEBVTCNdQwC9pLJ
Implementation of a control and monitoring system for a cathodic protection cell to mitigate localized corrosion in fixed and mobile steel structures
...Show More Authors

The current study introduces a novel technique to handle electrochemical localized corrosion in certain limited regions rather than applying comprehensive cathodic protection (CP) treatment. An impressed current cathodic protection cell (ICCPC) was fabricated and firmly installed on the middle of a steel structure surface to deter localized corrosion in fixed or mobile steel structures. The designed ICCPC comprises three essential parts: an anode, a cathode, and an artificial electrolyte. The latter was developed to mimic the function of the natural electrolyte in CP. A proportional-integrated-derivative (PID) controller was designed to stabilize this potential below the ICCPC at a cathodic potential of −850 mV, which is crucial for protection efficacy. The controller of the protection system was designed to automatically activate the ICCPC when the environment of the steel structure is exposed to humidity. At a temperature range from 27 °C to 35 °C, the protection potential, current, and power showed an increase in percentage by 411 %, 688.74 %, and 2842.3 %, respectively when the humidity level rose from 10 % to 100 %. The intended spraying of sodium chloride (NaCl) solution on the structure at different concentrations from 1.5 % to 5 % showed excellent protection against corrosion, notable improvements in electrical conductivity, and reduction in resistance between the anode and cathode. The energy dispersive spectroscopy and scanning electron microscopy (SEM-EDS) analyses confirm effective corrosion inhibition under ICCPC coverage compared to unprotected areas. These tests revealed an absence of oxidation beneath the ICCPC compared with areas outside of its coverage. The areas outside of ICCPC protection showed a reduction in iron and carbon contents from 57.1 % to 47.0 % and 41.4 %–22.4 %, respectively, and an increase in oxygen from 1.6 % to 30.6 %.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jun 15 2017
Journal Name
International Journal Of Computer Applications
Analytical and Numerical Study of the Temperature Distribution for a Solid Sphere subjected to a Uniform Heat Generation
...Show More Authors

View Publication
Crossref (2)
Crossref
Publication Date
Tue Jun 01 2021
Journal Name
Bulletin Of Electrical Engineering And Informatics
A new pseudorandom bits generator based on a 2D-chaotic system and diffusion property
...Show More Authors

A remarkable correlation between chaotic systems and cryptography has been established with sensitivity to initial states, unpredictability, and complex behaviors. In one development, stages of a chaotic stream cipher are applied to a discrete chaotic dynamic system for the generation of pseudorandom bits. Some of these generators are based on 1D chaotic map and others on 2D ones. In the current study, a pseudorandom bit generator (PRBG) based on a new 2D chaotic logistic map is proposed that runs side-by-side and commences from random independent initial states. The structure of the proposed model consists of the three components of a mouse input device, the proposed 2D chaotic system, and an initial permutation (IP) table. Statist

... Show More
View Publication
Scopus (12)
Crossref (6)
Scopus Crossref
Publication Date
Sat Dec 17 2022
Journal Name
Journal Of Al-ma'moon College
Simulation and Implementation of SNR Measurement processor for Adaptive Communication Systems
...Show More Authors

Preview PDF
Publication Date
Mon Apr 27 2020
Journal Name
Journal Of Mechanics Of Continua And Mathematical Sciences
A COMPARISON OF TOPOLOGICAL KRIGING AND AREA TO POINT KRIGING FOR IRREGULAR DISTRICT AREA IN IRAQ
...Show More Authors

View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Mon Dec 11 2017
Journal Name
Al-khwarizmi Engineering Journal
Design and Implementation for 3-DoF SCARA Robot based PLC
...Show More Authors

Abstract 

This paper presents mechanical and electrical design, and implementation  process of industrial robot, 3-DoF type SCARA (selective compliment assembly robot arm),with two rotations and one translation used for welding applications.The design process also included the controller design which was based on PLC(programmable logic controller) as well as selection of mechanical and electrical components.The challenge was to use the available components in Iraq with reasonable costs. The robot mentioned is fully automated using programmable logic controller PLC(Zelio type SR3-B261BD),with 16inputs and 10 outputs. The PLC was implemented in FBD logic to obtain three different automatic motions with hi

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Sun Jul 09 2023
Journal Name
Journal Of Engineering
A Comparative Study of Various Intelligent Algorithms Based Nonlinear PID Neural Trajectory Tracking Controller for the Differential Wheeled Mobile Robot Model
...Show More Authors

This paper presents a comparative study of two learning algorithms for the nonlinear PID neural trajectory tracking controller for mobile robot in order to follow a pre-defined path. As simple and fast tuning technique, genetic and particle swarm optimization algorithms are used to tune the nonlinear PID neural controller's parameters to find the best velocities control actions of the right wheel and left wheel for the real mobile robot. Polywog wavelet activation function is used in the structure of the nonlinear PID neural controller. Simulation results (Matlab) and experimental work (LabVIEW) show that the proposed nonlinear PID controller with PSO
learning algorithm is more effective and robust than genetic learning algorithm; thi

... Show More
View Publication Preview PDF
Crossref (3)
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Ieee Transactions On Human-machine Systems
Myoelectric Control With Fixed Convolution-Based Time-Domain Feature Extraction: Exploring the Spatio–Temporal Interaction
...Show More Authors

View Publication
Scopus (27)
Crossref (25)
Scopus Clarivate Crossref
Publication Date
Thu Sep 08 2022
Journal Name
Al-khwarizmi Engineering Journal
Study of Microbial Desalination Cell Performance; Power Generation and Desalination Efficiency using Pure Oxygen in a Cathode Chamber
...Show More Authors

Microbial Desalination Cell (MDC) is capable of desalinating seawater, producing electrical power and treating wastewater. Previously, chemical cathodes were used, which were application restrictions due to operational expenses are quite high, low levels of long-term viability and high toxicity. A pure oxygen cathode was using, external resistance 50 and 150 k Ω were studied with two concentrations of NaCl in the desalination chamber 15-25 g/L which represents the concentration of brackish water and sea water. The highest energy productivity was obtained, which amounted to 44 and 46 mW/m3, and the maximum limit for desalination of saline water was (31% and 26%) for each of 25 g / L and 15 g / L, respectively, when using an ex

... Show More
View Publication Preview PDF
Scopus (9)
Crossref (4)
Scopus Crossref
Publication Date
Thu Oct 18 2018
Journal Name
European Journal Of Organic Chemistry
PdII-Mediated Oxidative Amination for Access to a 9-Azabicyclo[4.2.1]nonane Compound Library and Anatoxin-a
...Show More Authors

View Publication Preview PDF
Crossref (4)
Clarivate Crossref
Publication Date
Sat Jun 30 2012
Journal Name
Al-kindy College Medical Journal
The Necessity of Teaching Diabetic Patients the Correct way of Insulin Administration: A Clinical Trial to Improve Glycemic Control
...Show More Authors

Background: It is important to achieve good glycemic control to avoid long-term diabetic complications. It has been largely debated about the role of correct way of insulin administration to get the desired glycemic control.
Objective: To evaluate the effect of teaching diabetic patients who are on insulin therapy the correct way of injecting insulin and its effect on glycemic control.
Methods: A non randomized clinical trial with 820 diabetic patients on insulin therapy on whom A1 c estimation was performed before and after three months of teaching them the right injection technique.
Results : Sixty seven patients (8.17%) had A1 c 6.5% before they were enrolled in the study while the majority (753 patents, 91.82%) had A1 c 6.5%

... Show More
View Publication Preview PDF