The BEK family of flows have many important practical applications such as centrifugal pumps, steam turbines, turbo-machinery and rotor-stator devices. The Bödewadt, Ekman and von Kármán flows are particular cases within this family. The convective instability of the BEK family of rotating boundary-layer flows has been considered for generalised Newtonian fluids, power-law and Carreau fluids. A linear stability analysis is conducted using a Chebyshev collocation method in order to investigate the effect of shear-thinning and shear-thickening fluids for generalised Newtonian fluids on the convective Type I (inviscid crossflow) and Type II (viscous streamline curvature) modes of instability. The results reveal that shear-thinning power-law fluids have a universal stabilising effect across the entire BEK family of flows. However, the convective instability characteristics for the shear-thinning and shear-thickening Carreau fluids are affected by the value of the relaxation parameter k. The results reveal that Shear-thinning Carreau fluids have a small destabilising effect, while shear -thickening fluids have a slight stabilising effect on the Type I and Type II mode for the BEK family of flows when k =100. On the other hand, shear-thinning and shear-thickening Carreau fluids are found to have stabilising and destabilising effect, respectively for optimal relaxation value ko. The results are presented in terms of neutral curves and growth rates. Furthermore, an energy analysis is presented to gain insight into the underlying physical mechanisms behind the stabilising effects of generalized Newtonian fluids. In conclusion, the use of shear-thinning power-law and Carreau fluids with optimal value ko can be recommended to reduce skin-friction drag in enclosed rotor-stator devices for the entire BEK family of flows.
Background: With the increasing demands for adult orthodontics, a growing need arises to bond attachments to porcelain surfaces. Optimal adhesion to porcelain surface should allow orthodontic treatment without bond failure but not jeopardize porcelain integrity after debonding.The present study was carried out to compare the shear bond strength of metal bracket bonded to porcelain surface prepared by two mechanical treatments and by using different etching systems (Hydrofluoric acid 9% and acidulated phosphate fluoride 1.23%). Materials and Methods: The samples were comprised of 60 models (28mm *15mm*28mm) of metal fused to porcelain (feldspathic porcelain). They were divided as the following: group I (control): the porcelain surface left u
... Show MoreObjective: The aim of this study was to compare the marginal microleakage between bulk-fill, preheated bulk-fill, and bulk-fill flowable composite resins above and below cemento-enamel junction (CEJ) using micro-computed tomography. Methods: Sixty freshly extracted premolar teeth were prepared with a slot shaped cavities of a total of 120 Class II: 3mm (bucco-lingual), 2mm (mesio-distal) with mesial-gingival margin located 1mm coronal to CEJ, and distal gingival margin located 1mm apical to the CEJ. The samples were randomly divided into two main groups according to the restorative material (Tetric EvoCeram and 3M Filtek), and each group was further sub-divided into three subgroups according to the consistency (bulk fill, preheated bulk fil
... Show MoreType 2 diabetes mellitus (T2DM) is a prevalent metabolic disorder caused by impaired insulin secretion from pancreatic β-cells and insulin resistance in target tissues. Genome-wide association studies have identified over 50 genetic variants linked to T2DM, including polymorphisms associated with the disease. This study investigates the impact of the FADS1 (rs174547) polymorphism in T2DM patients compared to healthy controls and examines serum levels of omega-3 and omega-6 fatty acids, as well as D5D and D6D enzyme levels and activity. This case–control study included 120 participants: 60 newly diagnosed T2DM patients and 60 apparently healthy controls matched for age, sex, and other sociodemographic factors. Polyunsaturated fatt
... Show MoreNew Schiff base ligand (E)-6-(2-(4-(dimethylamino)benzylideneamino)-2-(4-hydroxyphenyl)acetamido)-3,3- dimethyl-7-oxo-4-thia-1- azabicyclo[3.2.0]heptane-2-carboxylic acid = (HL) was synthesized via condensation of Amoxicillin and 4(dimethylamino)benzaldehyde in methanol. Figure -1 Polydentate mixed ligand complexes were obtained from 1:1:2 molar ratio reactions with metal ions and HL, 2NA on reaction with MCl2 .nH2O salt yields complexes corresponding to the formulas [M(L)(NA)2Cl],where M=Fe(II),Co(II),Ni(II),Cu(II),and Zn(II), A=nicotinamide .
Background: The association between facial types and dental arches forms has considerable implications in orthodontic diagnosis and treatment planning. The aim was to establish the maxillary and mandibular dental arches width and length in skeletal and dental class II division 1 and class III malocclusion groups, find out the most frequent dental arch form and facial type and the association between them and to check the gender differences. Materials and Methods: Frontal and lateral facial photographs and maxillary and mandibular occlussal photographs for 90 iraqi subjects with age 18-25 years old (45 males and 45 females) divided equally into three groups, the 1st group with class II division 1malocclusion (overjet more than 3mm but less t
... Show More