The extraction of pesticides is a critical and urgent issue in the preparation for and determination of pesticide residues. The lack of a quick, easy, and successful extraction process is the most critical and challenging problem, even if diagnostic tools have improved and pesticide residues have been better understood. This study contrasted the QuEChERS method, which uses gas chromatography with a flame ionization detector, with the LLE method, which uses liquid-liquid extraction, in order to extract pyridaben from cucumbers and spiromesifen from tomatoes. The GC-FID device was employed to ascertain the spiromesifen LOD and LOQ, which were 0.002 μg mL-1 and 0.006 g mL-1, respectively, according to the findings from the QuEChERS technique (95.6% recovery, RSD 0.28%-1.95%) and the LLE method (85.4% recovery, RSD 0.25%-6.9%). When testing the cucumber sample for pyridaben, the LLE method yielded an RSD of 0.12-0.21 percent, while the QuEChERS method yielded 95.22 percent. Pyridaben has limits of detection (LOD) of 0.001 μg mL-1 and quantification (LOQ) of 0.003 μg mL-1. A higher recovery level in both samples suggests that the QuEChERS method may be preferable to the LLE for extracting spiromesifen from tomatoes and pyridaben from cucumbers, according to the data. This was followed by a comparison of the two sets of results using a paired t-test with a 95% confidence level. Thus, the two methods are statistically distinct at the 95% confidence level. Among the most environmentally safe and sustainable solutions in this field, the QuEChERS method stands out for its quick sample preparation, affordability, ease of use, effectiveness, and absence of toxic chemicals and solvents.
Variation orders are an on-going phenomenon in construction and industry projects worldwide, particularly in the province of Sulaimani, where the project's damage from cost and schedule overrun because of variation orders. However, the effect on project costs and time overrun of variation order has yet to be identified. This study evaluates the impact of variation orders on the cost and time off in the Sulaimani governorate. Two hundred twenty-eight projects from various construction sectors built between 2007-2012 were adopted to calculate the contract cost and schedule overruns due to variation orders. Data analysis was applied in the study were descriptive statistics. One-way ANOVA was also applied to determine w
... Show MoreThe last decade has seen a variety of modifications of glass-ionomer cements (GICs), such as inclusion of bioactive glass particles and dispensing systems. Hence, the aim was to systematically evaluate effect of mixing modes and presence of reactive glass additives on the physical properties of several GICs.
The physical properties of eight commercial restorative GICs; Fuji IX GP Extra (C&H), KetacTM Fill Plus Applicap (C&H), Fuji II LC (C&H), Glass Carbomer Ce
with an organized propaganda campaign. This military campaign was helped to formulate its speech by many institutions, research centers, and knowledge and intelligence circles in order to mobilize public opinion gain supporters and face the opponents by different means depending on a variety of styles to achieve its required effects.
After the US occupation of Iraq, US media fighters sought to influence the Iraqi public opinion and making them convinced them of the important presence of US military forces in Iraq which necessitated finding its justification through the use of persuasive techniques in its intensive propaganda campaigns.
This research discusses the most important
Copper Telluride Thin films of thickness 700nm and 900nm, prepared thin films using thermal evaporation on cleaned Si substrates kept at 300K under the vacuum about (4x10-5 ) mbar. The XRD analysis and (AFM) measurements use to study structure properties. The sensitivity (S) of the fabricated sensors to NO2 and H2 was measured at room temperature. The experimental relationship between S and thickness of the sensitive film was investigated, and higher S values were recorded for thicker sensors. Results showed that the best sensitivity was attributed to the Cu2Te film of 900 nm thickness at the H2 gas.