Preferred Language
Articles
/
VxZzPYoBVTCNdQwCQJKH
New techniques to estimate the solution of autonomous system
...Show More Authors

This research aims to solve the nonlinear model formulated in a system of differential equations with an initial value problem (IVP) represented in COVID-19 mathematical epidemiology model as an application using new approach: Approximate Shrunken are proposed to solve such model under investigation, which combines classic numerical method and numerical simulation techniques in an effective statistical form which is shrunken estimation formula. Two numerical simulation methods are used firstly to solve this model: Mean Monte Carlo Runge-Kutta and Mean Latin Hypercube Runge-Kutta Methods. Then two approximate simulation methods are proposed to solve the current study. The results of the proposed approximate shrunken methods and the numerical simulation methods are compared with the standard results of the numerical method which is Runge-Kutta 4th Method from the year 2021 to 2025, using the absolute error, through comparison, it becomes clear that the approximate proposed solution is better and closer to the standard solution than the solutions of other methods that used to solve this system. The results are tabulated and represented graphically, as well as a discussion to prove the efficiency of the proposed methods.

Scopus Clarivate Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Tue Mar 01 2016
Journal Name
Journal Of Baghdad College Of Dentistry
A Comparison of the Effectiveness of Reciprocating System with Continuous Rotary Systems in Non-Surgical Endodontic Retreatment
...Show More Authors

Background: Optimal root canal retreatment was required safe and efficient removal of filling material from root canal. The aim of this in vitro study was to compare the efficacy of reciprocating and continuous motion of four retreatment systems in removal of root canal filling material. Materials and Methods: Forty distal roots of the mandibular first molars teeth were used in this study, these roots were embedded in cold clear acrylic,roots were instrumented using crown down technique and rotary ProTaper systemize Sx to size F2 ,instrumentation were done with copiousirrigation of 2.5% sodium hypochlorite and 17% buffered solution of EDTA was used as final irrigant followed by distilledwater, roots were obturated with AH26 sealer and Prota

... Show More
Preview PDF
Publication Date
Mon Feb 25 2019
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
Using Classification of Brown risks in Evaluation of the internal control system: Application Research in Karbala University
...Show More Authors

Internal control system is a safety valve that preserves economic units assets and ensure the accuracy of financial data, as well as to obligation in the laws, regulations, administrative policies ,and improve the efficiency, effectiveness and economic of operation, so it has become imperative for these units attention to internal and developed control system The research problem in exposure the economic units when the exercise of their business to many of the risks to growth or hinder the achievement of its objectives and the risks (financial, operational, strategy, risk) and not it rely on risk Assessment according to modern scientific methods, as in Brown's risk Classification, Which led to the weakness of the internal control identif

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 07 2015
Journal Name
Baghdad Science Journal
The effect of changing the evacuated tube tilt angle and the fluid of the solar collector on the performance of a hybrid solar air conditioning system
...Show More Authors

In the hybrid coolingsolar systems , a solar collectoris used to convertsolar energy intoheat sourcein order to super heat therefrigerant leave thecompressor,andthisprocess helpsin the transformation ofrefrigerant state from gaseous statetothe liquid statein upper two-thirdsof thecondenserinstead of the lower two-thirdssuchas in thetraditional air-conditioning systems and this willreduce theenergyneeded torun the process ofcooling.In this research two hybrid air-conditioning system with an evacuated tube solar collector were used, therefrigerant was R22 and the capacity was 2 tons each.The tilt angle of the evacuated tube solar collector was changed and the solar collector fluid was replaced into oil instead of water.A comparison wasi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Oct 08 2025
Journal Name
Journal Of Physical Education
The impact of a computerized program (cogniplus) to develop the strength to focus and perform kinetic chain on the balance beam
...Show More Authors

View Publication
Publication Date
Wed Nov 01 2023
Journal Name
Iop Conference Series: Earth And Environmental Science
The Effect of Solar Panel Type on some Irrigation System Parameters and Bean Crop Germination Percentage
...Show More Authors
Abstract<p>An experiment was carried out at Al-Raed Research Station, which is located on the Baghdad-Anbar road during the winter season, in order to study the effect of the type of solar panels and irrigation system on some performance indicators of irrigation systems and germination percentage of bean crop (Vicia Faba L). A randomized complete block design (RCBD) was used with three replications. The experiment consist of two factors. 1st factor was the solar panel type with two levels : monocrystalline and polycrystalline. Second factor was the irrigation system with two levels Drip and sprinkler irrigation system the following indicators were studied : solar panel efficiency (%), Irrigation</p> ... Show More
View Publication
Scopus (1)
Scopus Crossref
Publication Date
Wed Jun 01 2022
Journal Name
Baghdad Science Journal
Design and Performance Investigation of a Solar- Powered Biological Greywater Treatment System in the Iraqi Climate
...Show More Authors

            The increase in population resulted in an increase in the consumption of water. The present work investigates the performance of a recycling solar- powered greywater treatment system for the purposes of irrigation, used to reduce the amount of waste grey water and reduce electricity consumption and reduce the costs of constructing large scale water treatment plants. The system consumes about 3814W per hour and provides water treatment about 1.4 m3 per day. The proposed system is designed to    residential, office and governmental buildings application. Tests are conducted in an office building at the Ministry of Science and Technology site in Baghdad. Laboratorial water samples testing analyses are co

... Show More
View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Thu Oct 29 2020
Journal Name
The 11th International Renewable Energy Congress (irec 2020)
Thermal efficiency Optimization of the evacuated tube solar water heater system by using mirror flat reflector
...Show More Authors

In this paper a comparison of the experimental of evacuated tube solar water heater systems with and without mirror flat reflector. The aim of using the reflector to improve thermal efficiency, and the data gathered which are (temperature, solar irradiation and time) for three days were compared. the results from compared data the temperature lower increase in evacuated tube solar water heater system without reflector than the temperature increase in evacuated tube solar water heater system with reflector .The results show (53, 39, 35) % for three days respectively that the evacuated tube solar water heater system with reflector has higher thermal efficiencies than the results (47, 28, 30) % for three days respectively thermal efficiencies

... Show More
View Publication
Crossref
Publication Date
Sun Mar 03 2013
Journal Name
Baghdad Science Journal
Comparison the Formation of Spark Corona Discharge between Tap and distilled Waters at Liquid Electrode System
...Show More Authors

In this paper, we studied the spark corona discharge in tap and distillited waters. The results show the shape of cone that generated on the tip of capillary tube is different with conductivity of liquids. The blue glow appears at the end of capillary tube and the drop extends into a cone. In addition, the conducitivity is affected on the relationship between the appearance of the blue glow discharge with the applied voltage. The size of the cone decreases with an increase in applied voltage. The cone diameter at the base of capillary tube oscillates with period approximately 1 Sec. this oscillates in the cone diameters is due to the change distance between the liquid electrode and the surface of liquid. The intensity of spark corona dis

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 06 2022
Journal Name
Journal Of Positive School Psychology
Designing A Quality Costing System In Commercial Banks (Applied Research In The Investment Bank Of Iraq)
...Show More Authors

Preview PDF
Publication Date
Fri Dec 01 2017
Journal Name
Journal Of Accounting And Financial Studies ( Jafs )
of the Government finance Statistics GFS System In StrengtheningThe Role Oversight on performance Centrally Funded Units
...Show More Authors

This study aims to highlight the role of financial control in the development of government performance through the use of "GFS" system and its application in the service of government units, which will help them in how to use financial resources efficiently through the quality of accounting information provided by this system in the financial statements that reflect the predictability in that fiscal policy of the state through government programs and activities fee as well as to identify weaknesses and address them quickly in order to avoid wastage and loss of public money, which leads to the possibility of utilization of available financial resources of the state to effectively and efficiently, has been reached that the failure of gove

... Show More
View Publication
Crossref