This study was carried out to measure the percentage of heavy metals pollution in the water of the Diyala river and to measure the percentage of contamination of these elements in the leafy vegetables grown on both sides of the Diyala river, which are irrigated by the contaminated river water (celery, radish, lepidium, green onions, beta vulgaris subsp, and malva). Laboratory analysis was achieved to measure the ratio of heavy element contamination (Pb, Fe, Ni, Cd, Zn and Cr) using flame atomic absorption spectrophotometer during the summer months of July and August for the year 2017. The study showed that the elements of zinc, chromium, nickel and cadmium were high concentrations and exceeded. The maximum concentration of these
... Show MoreThe present study was carried to evaluate antibacterial activity of Acetone, Alcholic (cold and hot) and Aqueaus(water) extracts of Citrus aurantifoliaseeds,against growth of some bacteria isolated from burns infections(Pseudomonas aeruginosa,Escherichia coli, Klebsiellapneumonia,Staphylococcusaureus)fromKindy HospitalIn Baghdad from March to June 2012.Antibiotic Sensitivity was done for all isolated bacteria used in this study.Results showed variation in antibacterial activity of different extracts against all tested bacteria by well diffusion technique in agar and measuring the diameter of inhibition zone, at concentration 250Mg-ml. Acetone extract had the greatest inhibitory effect followed by hot alcoholci extract, and then cold alcohol
... Show MoreLead toxicity elicits neurological damage which is a well-known disorder that has been considered to be a major cause for multiple condition such as behavioral defect; mental retardation; and nerve insufficient activity.
This research is designed to estimate potential protective effect of vinpocetine on neurotoxicity stimulated by lead acetate in rats.
Eighteen adult rats of both sexes were randomly enrolled into three groups. Each group includes 6 rats as followings: Group I- Rats were given 0.3ml normal saline solution orally; then intraperitoneal injection of 100μl of the normal saline was given 1h later; this group was considered as control. Group II- Rats were given an intraperitoneal injection of 20mg/kg lead acetate
... Show MoreIn this work, the possibility of a multiwavelength mode-locked fiber laser generation based on Four-Wave Mixing (FWM) induced by Fe2O3-SiO2 nanocomposite material is investigated for the first time. A multiwavelength mode-locked pulses fiber laser are generated from Ytterbium–doped fiber laser (YDFL) due to the combined action of high nonlinear absorption and high refractive coefficients of Fe2O3-SiO2 nanocomposite incorporated inside YDFL ring cavity. Up to more than 20 lasing lines in the 1040–1070 nm band with an equally lines separation of ~0.6 nm have been observed by just simple variation of passive modulation of the state of the polarization and the pump power altogether. Moreover, a passively mode-locked operation of YDFL laser
... Show MoreThe research aims to shed light on the amount of proceeds annual tax for each of the way the contract total and percentage of completion method - see which is better - as well as the current problems arising from the application method of the contract in full in settling accounts tax - to identify problems - related to postpone settling accounts tax in accordance with the way the contract fully and determine the advantages and disadvantages of each of the methods through practical application , and then use the results as inputs to help in the decision to confirm the continuation of the GCT using a full decade in settling accounts tax for long-term construction contracts or forgo them.
Were the result of research the existence of
... Show MoreA Mini-TEA CO2 laser system was designed and operated to obtain a pulse at 10.6 μm. Output energy of 30 mJ, with preionization pins, and pulse duration of 100ns were obtained. While an output energy of 6mJ and pulse duration of 100 ns in absence of pre-ionization were obtained. The system was operated with Ernest profile main-discharge electrodes. Dependencies of supply voltage and output laser energy on the pressure inside laser cavity were investigated as well as dependencies of supply voltage and output energy on the main capacitor(8CO2 : 8N2 : 82He :2CO). Efficiency of was calculated to be 4.4%.