The aim of the present study is to evaluate the change in the levels of glucagon, GLP-1 and GPCR in diabetic patient's and diabetic with dyslipidemia as metabolic syndrome. The study included 75 male aged ranged (30-50) years and with BMI (25-29) kg/m2 which divided into three groups as follows: group one (G1): consist of 25 subjects as healthy control group. Group two (G2): consist of 25 patient's with diabetes mellitus and group three (G3): consist of 25 patient's with diabetic and dyslipidemia as metabolic syndrome. Serum was used in determination of FBG, lipid profile, insulin, glucagon, GLP-1 and GPCR. Whole blood was determination of HbA1c. The results revealed significant elevation in FBG and HbA1c in G2 and G3 comparing to G1. While non-significant elevation was found in FBG and HbA1c in G3 comparing to G2. The results also, showed no significant elevation in each of TC, TG, LDL and VLDL in G2 comparing to G1. Whereas, significant elevation was noticed in these parameters when G3 comparing to G2 and G1. Also, the levels of HDL showed no significant reduction in G2 comparing to G1, while significant reduction was found in G3 comparing to G2 and G1. The results also, revealed no significant elevation in insulin levels in G2 comparing to G1. While significant elevation was found in G3 comparing to G2 and G1. Also, the results illustrated significant elevation in glucagon levels in G2 comparing to G1. While significant reduction was seen in G3 comparing to G2. Significant reduction in GLP-1 and GPCR levels was found in G2 comparing to G1. While significant elevation in these parameters noticed in G3 comparing to G2 and G1. The conclusion could be drawn from this study that dyslipidemia affecting GLP-1 and GPCR levels that may be these patient's at high risk for cardiovascular disease.
Abstract—The upper limb amputation exerts a significant burden on the amputee, limiting their ability to perform everyday activities, and degrading their quality of life. Amputee patients’ quality of life can be improved if they have natural control over their prosthetic hands. Among the biological signals, most commonly used to predict upper limb motor intentions, surface electromyography (sEMG), and axial acceleration sensor signals are essential components of shoulder-level upper limb prosthetic hand control systems. In this work, a pattern recognition system is proposed to create a plan for categorizing high-level upper limb prostheses in seven various types of shoulder girdle motions. Thus, combining seven feature groups, w
... Show MoreFree vibration behavior was developed under the ratio of critical buckling temperature of laminated composite thin plates with the general elastic boundary condition. The equations of motion were found based on classical laminated plate theory (CLPT) while the solution functions consists of trigonometric function and a continuous function that is added to guarantee the sufficient smoother of the so-named remaining displacement function at the boundaries, in this research, a modified Fourier series were used, a generalized procedure solution was developed using Ritz method combined with the imaginary spring technique. The influences of many design parameters such as angles of layers, aspect ratio, thickness ratio, and ratio of initial in-
... Show MoreHeuristic approaches are traditionally applied to find the optimal size and optimal location of Flexible AC Transmission Systems (FACTS) devices in power systems. Genetic Algorithm (GA) technique has been applied to solve power engineering optimization problems giving better results than classical methods. This paper shows the application of GA for optimal sizing and allocation of a Static Compensator (STATCOM) in a power system. STATCOM devices used to increase transmission systems capacity and enhance voltage stability by regulate the voltages at its terminal by controlling the amount of reactive power injected into or absorbed from the power system. IEEE 5-bus standard system is used as an example to illustrate the te
... Show MoreBackground: preparation of root canals is an important step in root canal treatment. Mechanical instrumentation of root canals cause an irregular layer of debris, known as the smear layer. As a result, several studies reported that preferring the removal of the smear layer. Objective: To study the influence of the energy (100 mJ) of Erbium, Chromium: Yttrium Scandium Gallium Garnet (Er,Cr:YSGG) laser at short pulse duration (60 μs) on smear layer removal of apical third after using Photon induced photoacoustic streaming technique. Materials and methods: Eighteen straight single-rooted mandibular premolars were used. The roots length were uniform to 14mm from the anatomic apex and
... Show MoreThe simulation of passively Q-switching is four non – linear first order differential equations. The optimization of passively Q-switching simulation was carried out using the constrained Rosenbrock technique. The maximization option in this technique was utilized to the fourth equation as an objective function; the parameters, γa, γc and β as were dealt with as decision variables. A FORTRAN program was written to determine the optimum values of the decision variables through the simulation of the four coupled equations, for ruby laser Q–switched by Dy +2: CaF2.For different Dy +2:CaF2 molecules number, the values of decision variables was predicted using our written program. The relaxation time of Dy +2: CaF2, used with ruby was
... Show MoreA novel demountable shear connector for precast steel-concrete composite bridges is presented. The connector uses high-strength steel bolts, which are fastened to the top flange of the steel beam with the aid of a special locking nut configuration that prevents bolts from slipping within their holes. Moreover, the connector promotes accelerated construction and overcomes the typical construction tolerance issues of precast structures. Most importantly, the connector allows bridge disassembly. Therefore, it can address different bridge deterioration scenarios with minimum disturbance to traffic flow including the following: (1) precast deck panels can be rapidly uplifted and replaced; (2) connectors can be rapidly removed and replaced; and (
... Show More
