Preferred Language
Articles
/
VRfJW5MBVTCNdQwCZNKg
Plasma Sclerostin Level in Multiple Myeloma
...Show More Authors
Background:

Multiple myeloma (MM) is a heterogenous plasma cell malignancy with various complications. Sclerostin is a Wingless-type (Wnt) inhibitor specifically expressed by osteocytes; it acts as a negative regulator of bone formation.

Objectives:

To assess plasma sclerostin level in MM patients and find its correlations with clinical and laboratory data, including osteolytic bone disease and international staging system (ISS).

Materials and Methods:

This cross-sectional study included 80 individuals: 40 newly diagnosed MM patients and 40 healthy adults. Patients were divided according to the presence of bone disease and ISS stage and were investigated for complete blood count, blood film and bone marrow (BM). Plasma levels of β2-microglobulin and sclerostin were measured using competitive and sandwich enzyme immunoassay techniques, respectively.

Results:

Sclerostin level was significantly increased in MM patients than control group (P < 0.001) and was significantly higher in those with osteolytic bone disease and/or pathological fractures than those without bone lytic lesions (P < 0.001). Patients with ISS stage III showed significantly higher sclerostin level than stages I and II (P = 0.003). High sclerostin levels were positively correlated with blood urea, serum creatinine, uric acid, and β2-microglobulin (P-values 0.034, <0.001, <0.018 and <0.001, respectively) and negatively with glomerular filtration rate (P = 0.001). No significant correlation was found with age, gender, hematological and other biochemical parameters.

Conclusions:

In newly diagnosed MM patients, the plasma sclerostin was significantly correlated with renal impairment. High levels of plasma sclerostin were also found in advanced disease stage and with the presence of significant bone disease.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Aug 01 2019
Journal Name
International Journal Of Research - Granthaalayah
CALCULATION OF MULTIPLE MIXING RATIOS OF GAMMA RAYS FROM 𝑡𝒅(𝒏,𝒏)πŸ”πŸŽ πŸπŸ’πŸβˆ’πŸπŸ“πŸŽ ) πŸ”πŸŽπ‘΅π’… πŸπŸ’πŸβˆ’πŸπŸ“πŸŽ INTERACTION
...Show More Authors

In the current research, multiple mixing ratios of gamma -transitions of the energy levels 60𝑁𝑑 142−150 isotopes populated in 𝑁𝑑(𝑛, 𝑛 ˊ 60 142−150 ) 60𝑁𝑑 142−150 interaction are calculated using the constant statistical tensor (CST) method. The results obtained are, in general, in good agreement or consistent, within the experimental error, with the results published in the previously researches. Existing discrepancies result from inaccuracies in the experimental results of previous works. The current results confirm the validity of the constant statistical tenser method of calculating the values of mixing ratios and its predictability of errors in experimental results

Publication Date
Tue Jan 01 2019
Journal Name
Acta Facultatis Medicae Naissensis
Operative treatment of femoral neck fractures with cannulated screws with and without platelet rich plasma in young adults: A comparative study
...Show More Authors

Many studies have evaluated the effect of platelet rich plasma (PRP) in the treatment of non-union fractures but few studies have investigated their effect on the union of femoral neck fractures or their functional outcome in young adults. The aim of this study was to evaluate the union time and functional outcome in young adult patients with femoral neck fracture managed by three cannulated screws injected with PRP and those managed by fixation only. This prospective study included 24 patients diagnosed with femoral neck fractures within 24 hours of presentation. Twelve cases in group A were managed by closed reduction and three cannulated screws fixation injected with PRP; twelve patients in group B were managed only by closed reduction a

... Show More
View Publication Preview PDF
Scopus Clarivate Crossref
Publication Date
Sat Jul 28 2018
Journal Name
Journal Of Engineering
Experimental Investigation for the Removal of Toxic Gases from Vehicle Exhaust using Non-Thermal Plasma
...Show More Authors

In this study, the use of non-thermal plasma theory to remove toxic gases emitted from a vehicle was experimentally investigated. A non-thermal plasma reactor was constructed in the form of a cylindrical tube made of Pyrex glass. Two stainless steel rods were placed inside the tube to generate electric discharge and plasma condition, by connecting with a high voltage power supply (up to 40 kV). The reactor was used to remove the contaminants of a 1.25-liter 4-cylinder engine at ambient conditions. Several tests have been carried out for a ranging speed from 750 to 4,500 rpm of the engine and varying voltages from 0 to 32 kV. The gases entering the reactor were examined by a gas analyzer and the gases concentration ratio

... Show More
View Publication Preview PDF
Crossref (4)
Crossref
Publication Date
Sat Jan 01 2022
Journal Name
Technologies And Materials For Renewable Energy, Environment And Sustainability: Tmrees21gr
Effect of cold atmospheric plasma on the wound of diabetic rats by FE-DBD system
...Show More Authors

This study explains the effect of non-thermal (cold) plasma on wound of diabetic rats by (FE-DBD) system, 3cm probe diameter is used. The output power was ranged from (12-20) W. The effect of non-thermal plasma on wounds of a diabetic was observed with different exposure durations (20,30) sec., the plasma exposure duration decreases the sugar level in blood and the diameter of the wound. These results indicate the cold plasma can be used to enhance the insulin level (i.e., blood sugar) and wounds treatment.

View Publication
Scopus Crossref
Publication Date
Tue Jan 08 2019
Journal Name
Iraqi Journal Of Physics
Effect of Argon and oxygen pressure on Zn magnetron plasma produced by RF power supply
...Show More Authors

In this work, the plasma parameters (electron temperature and
electron density) were determined by optical emission spectroscopy
(OES) produced by the RF magnetron Zn plasma produced by
oxygen and argon at different working pressure. The spectrum was
recorded by spectrometer supplied with CCD camera, computer and
NIST standard of neutral and ionic lines of Zn, argon and oxygen.
The effects of pressure on plasma parameters were studied and a
comparison between the two gasses was made.

View Publication Preview PDF
Crossref
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
A Comparative Study on the Electrical Characteristics of Generating Plasma by Using Different Target Sources
...Show More Authors

In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur

... Show More
View Publication Preview PDF
Scopus (21)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Wed Dec 18 2019
Journal Name
Baghdad Science Journal
Effect of the Dielectric Barrier Discharge Plasma on the Optical Properties of CDS Thin Film
...Show More Authors

Cadmium sulphide CdS films with 200 nm have been prepared by thermal evaporation technique on glass substrate at substrate room temperature under vacuum of 10-5mbar.In this paper, the effect of Dielectric Barrier Discharge plasma on the optical properties of the CdS film. The prepared films were exposed to different time intervals (0, 3, 5, 8) min. For every sample, the Absorption A, absorption coefficient α , energy gap Eg ,extinction coefficient K and dielectric constant ε were studied. It is found that the energy gap were decreased with exposure time, and absorption , Absorption coefficient, refractive index, extinction coefficient,  dielectric constant increased with time of exposure to the plasma. Our study conside

... Show More
View Publication Preview PDF
Crossref (2)
Clarivate Crossref
Publication Date
Sun Oct 21 2018
Journal Name
Iraqi Journal Of Physics
Spectroscopic study the plasma parameters for Pb doped CuO prepared by pulse Nd:YAG laser deposition
...Show More Authors

In this work, plasma parameters such as, the electron temperature )Te(, electron density ne, plasma frequency )fp(, Debye length )λD(
and Debye number )ND), have been studied using optical emission spectroscopy technique. The spectrum of plasma with different values of energy, Pb doped CuO at different percentage (X=0.6, 0.7, 0.8) were recorded. The spectroscopic study for these mixing under vacuum with pressure down to P=2.5×10-2 mbar. The results of electron temperature for X=0.6 range (1.072-1.166) eV, for X=0.7 the Te range (1.024-0.855) eV and X=0.8 the Te is (1.033-0.921) eV. Optical properties of CuO:Pb thin films were determined through the optical transmission method using ultraviolet visible spectrophotometer within the ra

... Show More
View Publication Preview PDF
Crossref (7)
Crossref
Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Effect of Ag nanoparticles on R6G laser dye hosted by PMMA polymerized by plasma jet
...Show More Authors

This work aim to prepare Ag/R6G/PMMA nanocomposite thin
films by In-situ plasma polymerization and study the changes in the
optical properties of fluorophore due to the presence of Ag
nanoparticles structures in the vicinity of the R6G laser dye. The
concentrations of R6G dye/MMA used are: 10-4M solutions were
prepared by dissolving the required quantity of the R6G dye in
MMAMonomer. Then Silver nanoparticles with 50 average particles
size were mixed with MMAmonomer with concentration of 0.3, 0.5,
0.7wt% to get R6G silver/MMA in liquid phase. The films were
deposited on glass substrates by dielectric barrier discharge plasma
jet. The Ag/R6G/PMMA nanocomposite thin films were
characterization by UV-Visible

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Aug 31 2019
Journal Name
Iraqi Journal Of Physics
A Study of the Spectroscopic Performance of Laser Produced CdTe(x):S(1-x) Plasma
...Show More Authors

Abstract

In this work, the plasma parameters (electron temperature (Te), electron density( ne), plasma frequency (fp) and Debye length (λD)) have been studied by using the spectrometer that collect the spectrum of Laser produce CdTe(X):S(1-X) plasma at X=0.5 with different energies. The results of electron temperature for CdTe range 0.758-0.768 eV also the electron density 3.648 1018 – 4.560 1018 cm-3  have been measured under vacuum reaching 2.5 10-2 mbar .Optical properties of CdTe:S were determined through the optical transmission method using ultraviolet visible spectrophotometer within the r

... Show More
View Publication Preview PDF
Crossref (1)
Crossref