Preferred Language
Articles
/
VRfJW5MBVTCNdQwCZNKg
Plasma Sclerostin Level in Multiple Myeloma
...Show More Authors
Background:

Multiple myeloma (MM) is a heterogenous plasma cell malignancy with various complications. Sclerostin is a Wingless-type (Wnt) inhibitor specifically expressed by osteocytes; it acts as a negative regulator of bone formation.

Objectives:

To assess plasma sclerostin level in MM patients and find its correlations with clinical and laboratory data, including osteolytic bone disease and international staging system (ISS).

Materials and Methods:

This cross-sectional study included 80 individuals: 40 newly diagnosed MM patients and 40 healthy adults. Patients were divided according to the presence of bone disease and ISS stage and were investigated for complete blood count, blood film and bone marrow (BM). Plasma levels of β2-microglobulin and sclerostin were measured using competitive and sandwich enzyme immunoassay techniques, respectively.

Results:

Sclerostin level was significantly increased in MM patients than control group (P < 0.001) and was significantly higher in those with osteolytic bone disease and/or pathological fractures than those without bone lytic lesions (P < 0.001). Patients with ISS stage III showed significantly higher sclerostin level than stages I and II (P = 0.003). High sclerostin levels were positively correlated with blood urea, serum creatinine, uric acid, and β2-microglobulin (P-values 0.034, <0.001, <0.018 and <0.001, respectively) and negatively with glomerular filtration rate (P = 0.001). No significant correlation was found with age, gender, hematological and other biochemical parameters.

Conclusions:

In newly diagnosed MM patients, the plasma sclerostin was significantly correlated with renal impairment. High levels of plasma sclerostin were also found in advanced disease stage and with the presence of significant bone disease.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Jan 23 2020
Journal Name
Acoustics Australia
Absorption Coefficient of a Double-Layer Inhomogeneous Micro-perforated Panel Backed with Multiple Cavity Depths
...Show More Authors

Double-layer micro-perforated panels (MPPs) have been studied extensively as sound absorption systems to increase the absorption performance of single-layer MPPs. However, existing proposed models indicate that there is still room for improvement regarding the frequency bands of absorption for the double-layer MPP. This study presents a double-layer MPP formed with two single MPPs with inhomogeneous perforation backed by multiple cavities of varying depths. The theoretical formulation is developed using the electrical equivalent circuit method to calculate the absorption coefficient under a normal incident sound. The simulation results show that the proposed model can produce absorption coefficient with wider absorption bandwidth compared w

... Show More
View Publication
Scopus (21)
Crossref (19)
Scopus Clarivate Crossref
Publication Date
Tue Aug 31 2021
Journal Name
Al-kindy College Medical Journal
Assessment of the Effects of SARS-Cov-2 Infection on Multiple Organs Using Laboratory Indices
...Show More Authors

Background: Severe acute respiratory syndrome coronavirus 2 (SARS-Cov-2) is still a severe threaft for human health currently, and the researches about it is a focus topic worldwide.

Aim of the study: In this study, we will collect some laboratory results of the patients with coronavirus disease (COVID-19) to assess the function of liver, heart, kidney and even pancreas. 

Subjects and Methods: Laboratory results of the patients with COVID-19 are collected. The biochemical indices are classified and used to assess the according function of liver, heart, kidney; meantime, and blood glucose is also observed and taken as an index to roughly evaluate pancreas.

Results: There were some in

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Thu Nov 05 2015
Journal Name
Spectroscopy Europe
Fast and versatile ambient surface analysis by plasmaassisted desorption/ionisation mass spectrometry
...Show More Authors

has experienced a step-change since the inception of ambient mass spectrometry removed the requirement for samples to be investigated under vacuum conditions. Approaches based on surface– plasma interactions are especially promising, including PADI. Whilst the mechanisms involved in generating PADI spectra still need to be unravelled, PADI shows significant promise to become a valuable and versatile tool in the instrumental arsenal available to the surface analyst

Publication Date
Sat Oct 01 2022
Journal Name
International Journal Of Nanoscience
Preparation and Physical Properties of Mg-Zn Nano-crystal by Laser-induced Plasma
...Show More Authors

To learn how the manner of preparation influences film development, this study examined film expansion under a variety of deposition settings. To learn about the membrane’s properties and to ascertain the optimal pretreatment conditions, which are represented by ambient temperature and pressure, Laser pressure of 2.5[Formula: see text]m bar, the laser energy density of 500[Formula: see text]mJ, distortion ratio ([Formula: see text]) as a function of laser pulse count, all achieved with the double-frequency Nd: YAG laser operating in quality-factor mode at 1064[Formula: see text]nm. MgxZn[Formula: see text] films of thickness [Formula: see text][Formula: see text]nm were deposited on glass substrates at pulse

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Analysis of Initiation and Growth of Plasma Channels Within Non-Mixed Dielectric Liquids
...Show More Authors

Pre-breakdown phenomenon was investigated within the two, non-mixed dielectric liquids; transformation oil and cresol. Finite element technique was used to follow the initiation and growth of plasma channels (streamer discharge) within pin-plane configuration. That was done for different spacing between the pin-electrode and the liquid-liquid interface. Streamer growth model assumed that, the streamer initiation occurs at the region of the highest value of electric field. Our study shows that the streamer initiates at the tip of the pin and growths toward the other electrode. The study shows, too, that the streamer path controlled by the difference of permittivity of the two liquids and spacing distance of the liquid-liquid interface fro

... Show More
View Publication Preview PDF
Publication Date
Sun Jun 04 2017
Journal Name
Baghdad Science Journal
Texture Analysis of smear of Leukemia Blood Cells after Exposing to Cold Plasma
...Show More Authors

Plasma physics and digital image processing technique (DIPT) were utilized in this research to show the effect of the cold plasma (plasma needle) on blood cells. The second order statistical features were used to study this effect. Different samples were used to reach the aim of this paper; the patients have leukemia and their leukocytes number was abnormal. By studying the results of statistical features (mean, variance, energy and entropy), it is concluded that the blood cells of the sample showed a good response to the cold plasma.

View Publication Preview PDF
Scopus (23)
Crossref (2)
Scopus Crossref
Publication Date
Tue Oct 30 2018
Journal Name
Iraqi Journal Of Physics
The emission spectra and hydrodynamic properties of Al plasma using Nd-YAG laser
...Show More Authors

In this work, the emission spectra and atomic structure of the aluminum target had been studied theoretically using Cowan code. Cowan code was used to calculate the transitions of electrons between atomic configuration interactions using the mathematical method called (Hartree-Fock). The aluminum target can give a good emission spectrum in the XUV region at 10 nm with oscillator strength of 1.82.
The hydrodynamic properties of laser produced plasma (LPP) were investigated for the purpose of creating a light source working in the EUV region. Such a light source is very important for lithography (semiconductor manufacturing). The improved MEDUSA (Med103) code can calculate the plasma hydrodynamic properties (velocity, electron density,

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Effects of Gas Flow on Spectral Properties of Plasma Jet Induced by Microwave
...Show More Authors

In this paper, a construction microwave induced plasma jet(MIPJ) system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate using flow meter regulator. The influence of the MIPJ parameters such as applied voltage and argon gas flow rate on macroscopic microwave plasma parameters were studied. The macroscopic parameters results show increasing of microwave plasma jet length with increasing of applied voltage, argon gas flow rate where the plasma jet length exceed 12 cm as maximum value. While the increasing of argon gas flow rate will cause increasing into the ar

... Show More
View Publication Preview PDF
Scopus (17)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Wed Jan 01 2020
Journal Name
International Conference Of Numerical Analysis And Applied Mathematics Icnaam 2019
Synthesis of nanostructure diamond-like carbon thin films by atmospheric pressure plasma jet
...Show More Authors

In this work, diamond-like carbon (DLC) thin films were prepared from Cyclohexane. Thin films were deposited on quartz substrate by atmospheric pressure Argon plasma jet system. The plasma jet system was applying high voltage sinusoidal waves of frequency 28 kHz and potential difference of 7.5kV peak to peak across the electrodes. The effect of annealing at 400, 500 and 600 °C under vacuum for two hours on optical properties and structural properties of the DLC thin films were investigated. This effect was clarified by X-ray diffraction (XRD), FTIR, UV-Visible absorption, Scanning Electron Microscopy (SEM) and Raman Spectroscopy. The X-ray diffraction patterns for the annealing DLC thin films show two broad peaks at 2θ, 26.62° and 51.58

... Show More
View Publication
Scopus (2)
Crossref (2)
Scopus Clarivate Crossref
Publication Date
Fri Oct 01 2010
Journal Name
Iraqi Journal Of Physics
Investigation of plasma characteristics of center region of post cylindrical magnetron sputtering device
...Show More Authors

A d.c. magnetron sputtering system was designed and fabricated. The chamber of this system is consisted from two copper coaxial cylinders. The inner one used as the cathode and the outer one used as anode with magnetic coil located on the outer cylinder (anode). The axial behavior of the magnetic field strength along the cathode surface for various coil current (from 2A to 14A) are shown. The results of this work are investigated by three cylindrical Langmuir probes that have different diameters that are 2.2mm, 1mm, and 0.45mm. The results of these probes show that, there are two Maxwellian electron groups appear in the central region. As well as, the density of electron and ion decreases with increases of magnetic field strengths.

View Publication Preview PDF