Preferred Language
Articles
/
VRfJW5MBVTCNdQwCZNKg
Plasma Sclerostin Level in Multiple Myeloma
...Show More Authors
Background:

Multiple myeloma (MM) is a heterogenous plasma cell malignancy with various complications. Sclerostin is a Wingless-type (Wnt) inhibitor specifically expressed by osteocytes; it acts as a negative regulator of bone formation.

Objectives:

To assess plasma sclerostin level in MM patients and find its correlations with clinical and laboratory data, including osteolytic bone disease and international staging system (ISS).

Materials and Methods:

This cross-sectional study included 80 individuals: 40 newly diagnosed MM patients and 40 healthy adults. Patients were divided according to the presence of bone disease and ISS stage and were investigated for complete blood count, blood film and bone marrow (BM). Plasma levels of β2-microglobulin and sclerostin were measured using competitive and sandwich enzyme immunoassay techniques, respectively.

Results:

Sclerostin level was significantly increased in MM patients than control group (P < 0.001) and was significantly higher in those with osteolytic bone disease and/or pathological fractures than those without bone lytic lesions (P < 0.001). Patients with ISS stage III showed significantly higher sclerostin level than stages I and II (P = 0.003). High sclerostin levels were positively correlated with blood urea, serum creatinine, uric acid, and β2-microglobulin (P-values 0.034, <0.001, <0.018 and <0.001, respectively) and negatively with glomerular filtration rate (P = 0.001). No significant correlation was found with age, gender, hematological and other biochemical parameters.

Conclusions:

In newly diagnosed MM patients, the plasma sclerostin was significantly correlated with renal impairment. High levels of plasma sclerostin were also found in advanced disease stage and with the presence of significant bone disease.

Scopus Crossref
View Publication Preview PDF
Quick Preview PDF
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
The influence of cold atmospheric pressure plasma on TSH and thyroid hormones in male rats
...Show More Authors

View Publication
Scopus (3)
Crossref (1)
Scopus Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Iraqi Journal Of Physics
A computer experiment to study the charging process of dust grains in negative ion plasma
...Show More Authors

This work presents a computer studying to simulate the charging process of a dust grain immersed in plasma with negative ions. The study based on the discrete charging model. The model was developed to take into account the effect of negative ions on charging process of dust grain.
The model was translated to a numerical calculation by using computer programs. The program of model has been written with FORTRAN programming language to calculate the charging process for a dust particle in plasma with negative ion, the time distribution of a dust charge, number charge equilibrium and charging time for different value of ηe (ratio of number density of electron to number density of positive ion).

View Publication Preview PDF
Publication Date
Fri Mar 01 2019
Journal Name
Iraqi Journal Of Physics
Influence of working pressure and lasing energy of Al plasma in laser-induced breakdown spectroscopy
...Show More Authors

Aluminum plasma was generated by the irradiation of the target
with Nd: YAG laser operated at a wavelength of 1064 nm. The
effect of laser power density and the working pressure on spectral
lines generating by laser ablation, were detected by using optical
spectroscopy. The electron density was measured using the Stark
broadening of aluminum lines and the electron temperature by
Boltzmann plot method it is one of the methods that are used. The
electron temperature Te, electron density ne, plasma frequency
and Debye length increased with increasing the laser peak
power. The electron temperature decrease with increasing gas
pressure.

View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Arpn Journal Of Engineering And Applied Sciences
Achieving a theoretical approximation characterize the stopping power of heavy ion in D-T plasma
...Show More Authors

The dependence of the energy losses or the stopping power for the ion contribution in D- T hot plasma fuels upon the corresponding energies and the related penetrating factorare arrive by using by a theoretical approximation models. In this work we reach a compatible agreement between our results and the corresponding experimental results.

View Publication Preview PDF
Scopus
Publication Date
Mon Sep 10 2018
Journal Name
Iraqi Journal Of Physics
The influence of magnetic field and cathode dimensions on plasma characteristics in hollow cathode system
...Show More Authors

Experimental study on the effect of cylindrical hollow cathode, working pressure and magnetic field on spatial glow distribution and the characteristics of plasma produced by dc discharge in Argon gas, were investigated by image analyses for the plume within the plasma. It was found that the emission intensity appears as a periodic structure with many peaks appeared between the electrodes. Increasing the pressure leads to increase the number of intensity peaks finally converted to continuous form at high pressure, especially with applied of magnetic field, i.e. the plasma is more stable with the presence of magnetic field. The emission intensity study of plasma showed that the intensity has a maximum value at 1.07 mbar pressure and decre

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jan 01 2018
Journal Name
International Journal Of Medical Research & Health Sciences
Non-Surgical Treatment of Gingival Recession by Platelet-Rich Plasma
...Show More Authors

Publication Date
Sun Feb 03 2019
Journal Name
Iraqi Journal Of Physics
Influence of non-thermal argon plasma needle on blood coagulation
...Show More Authors

Non-thermal argon plasma needle at atmospheric pressure was
constructed. The experimental setup was based on a simple and low
cost electric component that generates a sufficiently high electric
field at the electrodes to ionize the argon gas which flow at
atmospheric pressure. A high AC power supply was used with 1.1
kV and 19.57 kHz. Non-thermal Argon plasma used on blood
samples to show the ability of non-thermal plasma to promote blood
coagulation. Three tests have been done to show the ability of plasma
to coagulate both normal and anti-coagulant blood. Each blood
sample has been treated for varying time from 20sec. to 180sec. at
different distances. The results of the current study showed that the
co

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Oct 01 2018
Journal Name
International Journal Of Medical Research & Health Sciences
Non-Surgical Treatment of Gingival Recession by Platelet-Rich Plasma
...Show More Authors

Preview PDF
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Estimation of electron temperature for SiO2 plasma induced by laser
...Show More Authors

In this work; Silicon dioxide (SiO2) were fabricated by pulsed
laser ablation (PLA). The electron temperature was calculated by
reading the data of I-V curve of Langmuir probe which was
employed as a diagnostic technique for measuring plasma properties.
Pulsed Nd:YA Glaser was used for measuring the electron
temperature of SiO2 plasma plume under vacuum environment with
varying both pressure and axial distance from the target surface. The
electron temperature has been measured experimentally and the
effects of each of pressure and Langmuir probe distance from the
target were studied. An inverse relationship between electron
temperature and both pressure and axial distance was observed.

View Publication Preview PDF
Crossref
Publication Date
Mon Feb 04 2019
Journal Name
Iraqi Journal Of Physics
Diagnostics of low-pressure capacitively coupled RF discharge argon plasma
...Show More Authors

Low-pressure capacitively coupled RF discharge Ar plasma has been studied using Langmuir probe. The electron temperature, electron density and Debay length were calculated under different pressures and electrode gap. In this work the RF Langmuir probe is designed using 4MHz filter as compensation circuit and I-V probe characteristic have been investigated. The pressure varied from 0.07 mbar to 0.1 mbar while electrode gap varied from 2-5 cm. The plasma was generated using power supply at 4MHz frequency with power 300 W. The flowmeter is used to control Argon gas flow in the range of 600 standard cubic centimeters per minute (sccm). The electron temperature drops slowly with pressure and it's gradually decreased when expanding the electro

... Show More
View Publication Preview PDF
Crossref (1)
Crossref