BACKGROUND: Sacral nerve stimulation (SNS) approved for use in North America since 1997 despite the fact that the concept of using SNS to treat patients with voiding dysfunction discussed first almost 50 years ago. AIM: The objectives of the study were to assess the effectiveness of SNS the short and long term for patients with overactive bladder (OAB) dysfunction and its relation to age, gender, and causes. PATIENTS AND METHODS: This is a clinical prospective study that involved 50 cases (32 females and 18 males) with OAB. It was carried out at Ibn Sina Hospital, and the neurosciences hospital in Baghdad/Iraq from April 2015 to April 2018. All the patients were assessed preoperatively and certain inclusion criteria were used. The patients went through the 2 stage implantations of the Medtronic InterStim®. The patients were assessed at 6 months (short term) and 2 years (long term) postoperatively. RESULTS: The results of our patients were analyzed with respect to age, gender, causes of OAB, and post-operative complications. We found that younger age patients, female patients, and patients with neurogenic causes of OAB showed a better response in both the short- and long-term follow-up. CONCLUSION: Considerable progress has been made in the surgical management of OAB. Proper selection of patients is the key to the success of SNS, and female patients have better results compared to male patients. Furthermore, younger patients and patients with neurogenic causes did better than older patients and patients with idiopathic causes. SNS is a safe minimally invasive surgery with a low complication rate, and the 2 stages procedure has better results than the percutaneous nerve evaluation.
This study was design to investigate the dimensional stability of heat-activated acrylic resin with different methods of flask cooling (15 minutes rapid cooling, one hour bench cooling, four hours delayed deflasking, and 24 hours delayed deflasking) at different time intervals (immediately, two days, seven days, 30 days) after deflasking. Heat-activated acrylic resin was used to prepare acrylic samples. Then, measurement of the distances where achieved between the centers of selected marks in the acrylic samples. They were measured at different time intervals for different methods of flask cooling. The results showed that the group samples of the four hours and 24 hours of delayed deflasking was insignificantly different from the control an
... Show Morethin films of se:2.5% as were deposited on a glass substates by thermal coevaporation techniqi=ue under high vacuum at different thikness
Time-domain spectral matching commonly used to define seismic inputs to dynamic analysis in terms of acceleration time history compatible with a specific target response spectrum is used in this study to investigate the second-order geometric effect of P-delta on the seismic response of base-isolated high-rise buildings. A synthetic time series is generated by adjusting reference time series that consist of available readings from a past earthquake of the 1940 El Centro earthquake adopted as an initial time series. The superstructure of a 20-story base isolated building is represented by a 3-D finite element model using ETABS software. The results of the base isolated building show that base isolation technique significantly reduces inter-s
... Show MoreThe present study aims to detect CTX-M-type ESBL from Escherichia coli clinical isolates and to analyze their antibotic susceptibility patterns. One hundred of E. coli isolates were collected from different clinical samples from a tertiary hospital. ESBL positivity was determined by the disk diffusion method. PCR used for amplification of CTX-M-type ESBL produced by E. coli. Out of 100 E. coli isolates, twenty-four isolates (24%) were ESBL-producers. E. coli isolated from pus was the most frequent clinical specimen that produced ESBL (41.66%) followed by urine (34.21%), respiratory (22.23%), and blood (19.05%). After PCR amplification of these 24 isolates, 10 (41.66%) isolates were found to possess CTX-M genes. The CTX-M type ESBL
... Show MoreThere are numbers of automatic translation services that internet users can choose to automatically translate a certain text, and Google translate is one of these automatic services that proposes over 51 Languages. The present paper sheds light on the nature of the translation process offered by Google, and analyze the most prominent problems faced when Google translate is used. Direct translation is common with Google Translate and often results in nonsensical literal translations, particularly with long compound sentences. This is due to the fact that Google translation system uses a method based on language pair frequency that does not take into account grammatical rules which, in turn, affects the quality of the translation. The
... Show MoreAbstract—The upper limb amputation exerts a significant burden on the amputee, limiting their ability to perform everyday activities, and degrading their quality of life. Amputee patients’ quality of life can be improved if they have natural control over their prosthetic hands. Among the biological signals, most commonly used to predict upper limb motor intentions, surface electromyography (sEMG), and axial acceleration sensor signals are essential components of shoulder-level upper limb prosthetic hand control systems. In this work, a pattern recognition system is proposed to create a plan for categorizing high-level upper limb prostheses in seven various types of shoulder girdle motions. Thus, combining seven feature groups, w
... Show More