Nanofertilizers offer a promising solution to increase crop yields amid increasing population pressure. Yet there have been safety concerns about their use, particularly in challenging conditions. This work was designed to assess the toxicological effects of a chelated multi-micronutrient nanofertilizer on albino rats (Rattus norvegicus) as non-target organisms, focusing on the liver, which has important metabolic functions. Thirty-five animals were weighed and randomly divided into 5 groups (n=7). A negative control group was included, and four experimental groups (C1-C4) were given the test item. The dosing regimen for the experimental groups was 15 oral doses of nanofertilizer every other day for 29 days. All the groups were treated with different doses (62.5, 125, 250, and 500 mg/kg, respectively). Biochemical analyses revealed a statistically significant reduction in lactate dehydrogenase (LDH) levels in groups C2 through C4 (661.00 ± 181.67, 572.43 ± 187.62, and 577.86 ± 110.84 U/L, respectively) compared to both the control (919.86 ± 232.08 U/L) and C1 (880.00 ± 119.17 U/L) groups. In contrast, serum total protein concentrations exhibited a marked increase across all treatment groups (C1–C4: 74.36 ± 3.91, 68.49 ± 5.88, 70.47 ± 7.93, and 68.14 ± 3.84 g/L, respectively), relative to the control (59.29 ± 5.49 g/L). This rise in total protein was mainly due to a significant increase in serum globulin, whereas albumin showed a marked decrease. Histological examination showed dose-dependent hepatotoxicity in all treatment groups. These results indicated that a sub-lethal dose of this nanofertilizer has the potential to elicit observable hepatotoxicity, underscoring the need for careful application and further toxicological evaluations.
This paper presents an experimental study of cooling photovoltaic (PV) panels using evaporative cooling. Underground (geothermal energy) water used to extract heat from it during cooling and cleaning of PV panels. An experimental test rig was constructed and tested under hot and dusty climate conditions in Baghdad. An active cooling system was used with auxiliary an underground water tank to provide cold water as a coolant over both PV surfaces to reduce its temperature. The cellulose pad has been arranged on the back surface and sprays cooling on the front side. Two identical PV panels modules used: without cooling and evaporative water cooling. The experiments are comprised of four cases: Case (I): backside cooling, Ca
... Show MoreIn the city, building space could transform to be as place, because architecture does not include only traditional values such as housing, human protection, stability, etc, but could carry other dimensions beyond the housing or building occupancy or develop urban design. Rivers had vision in motion as a way to show dynamic processes in its flowing slowly, which are simply measured in time and the life of citizens. The research consider the river path in traditional cities as Alley connecting the spaces of the city ... old Baghdad was characterized by this property and it is look like Venice in the past, while traditional European cities were able to preserve this property till now, and capable to take transformation of the city with deve
... Show MoreIn this work, an inventive photovoltaic evaporative cooling (PV/EC) hybrid system was constructed and experimentally investigated. The PV/EC hybrid system has the prosperous advantage of producing electrical energy and cooling the PV panel besides providing cooled-humid air. Two cooling techniques were utilized: backside evaporative cooling (case #1) and combined backside evaporative cooling with a front-side water spray technique (case #2). The water spraying on the front side of the PV panel is intermittent to minimize water and power consumption depending on the PV panel temperature. In addition, two pad thicknesses of 5 cm and 10 cm were investigated at three different water flow rates of 1, 2, and 3 lpm. In Case #1,
... Show MoreSoftware Defined Networking (SDN) with centralized control provides a global view and achieves efficient network resources management. However, using centralized controllers has several limitations related to scalability and performance, especially with the exponential growth of 5G communication. This paper proposes a novel traffic scheduling algorithm to avoid congestion in the control plane. The Packet-In messages received from different 5G devices are classified into two classes: critical and non-critical 5G communication by adopting Dual-Spike Neural Networks (DSNN) classifier and implementing it on a Virtualized Network Function (VNF). Dual spikes identify each class to increase the reliability of the classification
... Show MoreAbstract: -
The concept of joint integration of important concepts in macroeconomic application, the idea of cointegration is due to the Granger (1981), and he explained it in detail in Granger and Engle in Econometrica (1987). The introduction of the joint analysis of integration in econometrics in the mid-eighties of the last century, is one of the most important developments in the experimental method for modeling, and the advantage is simply the account and use it only needs to familiarize them selves with ordinary least squares.
Cointegration seen relations equilibrium time series in the long run, even if it contained all the sequences on t
... Show MoreReinforced concrete (RC) beams containing a longitudinal cavity have become an innovative development and advantage for economic purposes of light-weight members without largely affecting their resistance against the applied loads. This type of openings can also be used for maintenance purposes and usage space of communication lines, pipelines, etc. RC beams are primarily loaded in the plane of the members, which are two-dimensional in a plane stress state and the dominant structural behaviours include bending, shear, or combination of both. In the present study, six numerical models of RC beams with and without openings were simulated by using commercial finite element software ANSYS to evaluate the structural behaviours of those b
... Show MoreThermal management has become a major issue in the latest high performance computing machines because high CPU temperatures result in inefficient performance and decreased hardware life span. In this work, the cooling performance of a finned metal foam heat sink (FMFHS) was examined. The pore density values of tested copper metal foam (CMF) samples with different values of PPI 5, 10 and 20, with a constant porosity of 90%. For reference, these samples were measured by a conventional Aluminum plate-fin heat sink (CHS). The work was performed under experimental conditions in which air directed over the heat sink surface at air velocities (2.5, 3.0 and 3.5 m/s). The environmental temperature was fixed at 27 °C. Findings
... Show More