Background: Complete denture wearers show lower levels of bite force than dentate subjects. This has a significant influence on their chewing efficiency. In this study an attempt was made to investigate the effect of the impression technique on the maximum bite force in complete denture wearers. Materials and methods: The patients selected for this research were 12 edentulous patients. Three different techniques for registering the final impression were made; the mucostatic, mucofunctional, and the selective pressure impression technique. Two sets of upper and lower denture bases and one set of upper and lower dentures were constructed for each subject. Intraoral and extraoral instruments and devices, as well as a computer program were used for measuring the maximum bite force. Results: The subjects without past experience with complete dentures were able to give higher levels of bite force with dentures or denture bases constructed from the mucofunctional impression technique, while those with previous dentures gave higher levels of bite force with the dentures or denture bases constructed from the selective pressure impression technique. Conclusions: It is recommended that dentures constructed from the mucofunctional impression technique be used for those subjects without previous experience with complete dentures, while for those with previous complete dentures the selective pressure impression technique should be used.
In this paper, Pentacene based-organic field effect transistors (OFETs) by using different layers (monolayer, bilayer and trilayer) for three different gate insulators (ZrO2, PVA and CYEPL) were studied its current–voltage (I-V) characteristics by using the gradual-channel approximation model. The device exhibits a typical output curve of a field-effect transistor (FET). Source-drain voltage (Vds) was also investigated to study the effects of gate dielectric on electrical performance for OFET. The effect of capacitance semiconductor in performance OFETs was considered. The values of current and transconductance which calculated using MATLAB simulation. It exhibited a value of current increase with increasing source-drain voltage.
This research aims to find how three different types of mouthwashes affect the depth of artificial white spot lesions. Teeth with various depths of white spot lesions were immersed in either splat mouthwash, Biorepair mouthwash, Sensodyne mouthwash, or artificial saliva (control)twice daily for one minute for 4 weeks and 8 weeks at 37°C. After this immersion procedure, lesion depth was measured using a diagnosed pen score. A one-way analysis of variance, Dunnett T3 and Tukey's post hoc α = .05 were used to analyze the testing data. Splat mouthwash enhanced the WSL remineralization and made the lowest ΔF compared with other mouthwashes in shallow and deep enamel after 4 and 8 weeks of treatment. In the repair groups, after 4 weeks
... Show MoreIn this paper, Pentacene based-organic field effect transistors (OFETs) by using different layers (monolayer, bilayer and trilayer) for three different gate insulators (ZrO2, PVA and CYEPL) were studied its current–voltage (I-V) characteristics by using the gradual-channel approximation model. The device exhibits a typical output curve of a field-effect transistor (FET). Source-drain voltage (Vds) was also investigated to study the effects of gate dielectric on electrical performance for OFET. The effect of capacitancesemiconductor in performance OFETs was considered. The values of current and transconductance which calculated using MATLAB simulation. It exhibited a value of current increase with increasing source-drain voltage.
Background: Understanding the morphological characteristics between the floor of the maxillary sinus and the tips of the maxillary posterior roots is crucial in orthodontics involving diagnosis and treatment planning. The aim of this study was to evaluate the distances from the maxillary posterior root apices to the inferior wall of the maxillary sinus, thickness and density of maxillary sinus floor using cone-beam computed tomography images and the relationships between roots and maxillary sinus according to gonial angle and skeletal pattern. Materials and methods: Three-dimensional images of each root were checked, and the distances were measured along the true vertical axis from the apex of the root to the sinus floor, and the thickne
... Show MoreThe research aims to identify the future teachers' attitudes toward cloud computing in the Kingdom of Saudi Arabia from their point of view. The research adopted the descriptive approach, and a questionnaire was applied to a random sample of (370) male and female teachers in governmental and private general education schools in the Al-Jouf region, Saudi Arabia. The results of the research concluded that the reality of future teachers' attitudes towards cloud computing in the Kingdom of Saudi Arabia from their point of view is very high and that most areas of using computing are in the field of assessment, then teaching, and activities. The challenges of future teachers' attitudes toward cloud computing are recorded at a high level, parti
... Show MoreBackground: The aim of this study was to evaluate the shear bond strength (SBS) and adhesive remnant index (ARI) of different orthodontic adhesive systems after exposure to aging media (water storage and acid challenge). Materials and methods: Eighty human upper premolar teeth were extracted for orthodontic purposes and randomly divided into two groups (40 teeth each): the first group in which the bonded teeth were stored in distilled water for 30 days at 37°C, and the second group in which the bonded teeth were subjected to acid challenge. Each group was further subdivided into four subgroups (10 teeth each) according to the type of adhesive system that would be bonded to metal brackets: either non-fluoride releasing adhesive (NFRA),
... Show MoreABSTRACT Background: Color changes that are detectable to human eye can affect the esthetic appearance of ceramic veneers. The purpose of this study was to evaluate and compare the effect of artificial accelerated aging on the color of ceramic veneers cemented with different resin cements. Materials and Methods: Sixty discs were prepared with 0.5 mm thickness, 30 discs made from IPS e.max press (Ivoclar Vivadent) and 30 discs were made from VITA Enamic (VITA Zahnfabrik). The discs were cemented with three resin cements: Variolink Veneer MV 0 shade (Ivoclar Vivadent), Rely X veneer Translucent shade (3M ESPE) and NX3 Nexus Clear shade (Kerr Corporation) with 0.1 mm thickness. The spectrophotometer Easyshade Advance was used to measure the co
... Show MoreBackground: Anemia of chronic disease (ACD) occurs in the presence of chronic infection, inflammatory conditions or neoplastic conditions despite of adequate iron and vitamins storage. Gingivitis is the inflammation of the gingiva, periodontitis is the inflammation in the periodontium that extend deeper with loss of connective tissue attachment and supporting bone. The main pathogenesis of periodontal diseases and ACD is immune activation. Aims of study: Determine and compare the clinical periodontal parameters (plaque index (PLI), gingival index (GI), bleeding on probing (BOP), probing pocket depth (PPD) and clinical attachment level (CAL)). Evaluate the hematocrit (Hct) level, red blood cells (RBCs) count and white blood cells (WBCs) c
... Show MoreThe aim of this research is to study the effect of welded joint design (Butt joint and lap joint) on thejoint strength during tension and fatigue loading with different current of welding (40,50,60,70,80) ^per, and different type of wire welding. The result of this research is showed that the effect of fatigue loading on the type of joint is more than the effect of tension loading on it. And the butt joint welding is better than the lap joint welding during the fatigue loaded.The experimental results of the effect of W'elding current showed that more increasing and more decreasing the value of the heat input, during the welding was found to produce mechanical brittleness on the buttjoint welding during the static and dynamic loading. Also i
... Show MoreExogenous levothyroxine dose modulation and euthyroidism achievement is a persistent challenge in clinical settings. This study strives to assess the adequacy of treatment and identify the patients’ factors that can be used to estimate the euthyroid levothyroxine dose. A secondary objective was to assess vitamin D supplementation impact on thyroid status.
A review of a prospectively collected information from 142 female patients from Baghdad Center of Nuclear Medicine from June 2019 until March 2020 who were receiving levothyroxine for different causes was done. After a follow-up period, the patients’ thyroid tests were assessed and the euthyroid doses for each cause category were statistically analyzed. Thyroid function was
... Show More