Preferred Language
Articles
/
Uhb7KYcBVTCNdQwCdzts
Fire Flame Influence on the Behavior of reinforced Concrete Beams Affected by Repeated Load
...Show More Authors

The influence and hazard of fire flame are one of the most important parameters that affecting the durability and strength of structural members. This research studied the influence of fire flame on the behavior of reinforced concrete beams affected by repeated load. Nine self- compacted reinforced concrete beams were castellated, all have the same geometric layout (0.15x0.15x1.00) m, reinforcement details and compressive strength (50 Mpa). To estimate the effect of fire flame disaster, four temperatures were adopted (200, 300, 400 and 500) oC and two method of cooling were used (graduated and sudden). In the first cooling method, graduated, the tested beams were leaved to cool in air while in the second method, sudden, water splash was used to reduce the temperature. Eight of the tested beams were divided in to four groups, each were burned to one of the adopted temperature for about half an hour and cooled by the adopted cooling methods (one by sudden cooling and the other by graduated cooling). After burning and cooling the beams were tested under the effect of repeated load (loading – unloading) for five cycle and then up to failure. As a compared with the non- burned beam, the results indicated that the ultimate load capacity of the tested beams were reduced by (16, 23, 54 and 71)% after being burned to (200, 300, 400 and 500) oC , respectively, for a case of sudden cooling and by (8, 14, 36 and 64)% , respectively, for a case of graduated cooling. It was also found that the effect of sudden cooling was greater than that in a case of graduated cooling. Regarding the failure mode, there was a different between the non-burred beam and the other ones even that all of them had the same geometric layout, compressive strength and reinforcement details. The failure mode for all burned beams was combined shear- flexure failure which was belong to the reduction in the compressive strength of the concrete due to the effect of the temperature rising , while the failure mode of the non-burned beam was flexure failure which was compatible with the preliminary design. It was also detected that the residual deflection proportion directly with the temperature, as the temperature increase to (200, 300, 400 and 500) oC the residual deflection compared with the non-burned beam increased by (32, 48, 326 and 358)% for a case of sudden cooling and by (13, 29, 303 and 332)% for a case of graduated cooling. Another effect was appear represented by the method of cooling, the results showed that the sudden cooling had more effect on the residual deflection than the graduated cooling by (15-6)% approximately. To vanish the residual deflection, numbers of cycle (loading-unloading) were required. It was found that this number increase as the temperature of burning increased and it’s also larger in a case of sudden cooling.

Publication Date
Sun Jun 21 2020
Journal Name
Baghdad Science Journal
Structural and Thermal Unusual Properties in Invar Behavior of Ni-Mn Alloys
...Show More Authors

The Invar effect in 3D transition metal such as Ni and Mn, were prepared on a series composition of binary Ni1-xMnx system with x=0.3, 0.5, 0.8 by using powder metallurgy technique. In this work, the characterization of structural and thermal properties have been investigated experimentally by X-ray diffraction, thermal expansion coefficient and vibrating sample magnetometer (VSM) techniques. The results show that anonymously negative thermal expansion coefficient are changeable in the structure. The results were explained due to the instability relation between magnetic spins with lattice distortion on some of ferromagnetic metals.    

View Publication Preview PDF
Scopus (1)
Scopus Clarivate Crossref
Publication Date
Sun Aug 23 2020
Journal Name
Int’l Journal Of Advances In Chemical Engg., & Biological Sciences
Behavior Study Of Mating and Caring Young in Scorpions Androctonus crassicauda (Scorpiones:
...Show More Authors

Publication Date
Wed Jan 01 2020
Journal Name
Aip Conference Proceedings
Corrosion behavior of mild-steel in cooling towers using high salinity solution
...Show More Authors

Cooling towers is one of the most important unit in industry, they are used to dispose heat from cooling media used in the integrated units. The choice of the cooling media plays recently an important rule due to fresh-water scarcity. The use of saline as a cooling media become of growing interest, but the corrosion problem has to be taken in consideration. In this study the simultaneous effect of cooling tower operation parameters on the corrosion rate of mild-steel is considered. The role of NaCl content is found to be pronounced more than the working solution temperature and flowrate. The corrosion of mild-steel in these studied factors had shown an interesting result especially with the NaCl% content. Firstly, there was an increase in t

... Show More
View Publication
Scopus (8)
Crossref (4)
Scopus Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Iranian Journal Of Science And Technology, Transactions A: Science
Structural, Optical and Sensing Behavior of Neodymium-Doped Vanadium Pentoxide Thin Films
...Show More Authors

View Publication
Scopus (23)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Sat Oct 01 2022
Journal Name
Advances In Structural Engineering
Experimental and FE analysis of composite RC beams with encased pultruded GFRP I-beam under static loads
...Show More Authors

Publication Date
Sat Oct 01 2022
Journal Name
Advances In Structural Engineering
Experimental and FE analysis of composite RC beams with encased pultruded GFRP I-beam under static loads
...Show More Authors

Encasing glass fiber reinforced polymer (GFRP) beam with reinforced concrete (RC) improves stability, prevents buckling of the web, and enhances the fire resistance efficiency. This paper provides experimental and numerical investigations on the flexural performance of RC specimens composite with encased pultruded GFRP I-sections. The effect of using shear studs to improve the composite interaction between the GFRP beam and concrete was explored. Three specimens were tested under three-point loading. The deformations, strains in the GFRP beams, and slippages between the GFRP beams and concrete were recorded. The embedded GFRP beam enhanced the peak loads by 65% and 51% for the composite specimens with and without shear connectors,

... Show More
View Publication
Crossref (26)
Clarivate Crossref
Publication Date
Mon Jun 01 2026
Journal Name
Civil Engineering Journal
Dynamic Proportionality of Inertia and Reaction Forces in CFRP-Strengthened L-Shaped RC Beams under Impact Loading
...Show More Authors

This study computationally investigates to examine the impacts of repeated loading on L-shaped spandrel beams made of reinforced concrete, which were strengthened by externally bonded carbon fiber reinforced plastic sheets. The object of the research is to evaluate the following three aspects of structural behavior: degradation of reaction forces, evolution of inertia forces, and residual performance. Ayad and Oukaili's experimental impact-loading program, which featured midspan drop-weight loading on RC spandrel beams before and after strengthening, was used to validate a comprehensive three-dimensional finite element model created in ABAQUS. A sequence of 25 impacts before and 25 impacts after CFRP application was simulated to tra

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Jan 13 2019
Journal Name
Iraqi Journal Of Physics
Preparation and studying of some properties of polymer composites reinforced with natural and artificial fibers
...Show More Authors

This work concerns the thermal and sound insulation as well as the mechanical properties of polymer matrix composite reinforced with glass fibers. These fibers may have dangerous effect during handling, for example the glass fibers might cause some damage to the eyes, lungs and even skin. For this reason the present work, investigates the behavior of polymer composite reinforced with natural fibers (Plant fibers) as replacement to glass fibers. Unsaturated Polyester resin was used as matrix material reinforced with two types of fibers, one of them is artificial (Glass fibers) and the other type is natural (Jute, Fronds Palm and Reed Fibers) by hand lay-up technique. All fibers are untreated with any chemical solvent. The Percentage of mi

... Show More
View Publication Preview PDF
Crossref (6)
Crossref
Publication Date
Mon Jun 01 2026
Journal Name
Results In Engineering
Preliminary evaluation of surface functional properties of chitosan films reinforced with TiO₂ or ZnO nanoparticles
...Show More Authors

Biodegradable polymers have garnered increasing attention as eco-friendly alternatives to conventional petroleum-derived plastics, which pose a global environmental challenge due to their difficult recycling and slow degradation. This study focuses on the preliminary evaluation of surface functional properties of chitosan films reinforced with TiO₂ or ZnO nanoparticles (NPs). These films were prepared at different loading ratios using the solution-casting method. Structural and morphological properties were characterized using FTIR and FESEM, while functional properties were evaluated by surface wettability, UV–Vis spectroscopy, thermogravimetric analysis and antibacterial activity testing. FTIR results showed significant changes in abs

... Show More
View Publication Preview PDF
Scopus (1)
Crossref (1)
Scopus Crossref
Publication Date
Sun Sep 03 2017
Journal Name
International Journal Of Discrete Mathematics
Heavy Metals Pollution in Soil and Its Influence in South of Iraq
...Show More Authors

The aim of this paper is to determine the significant levels of some heavy metals such: lead, chromium, nickel and cadmium, were determined. Sources of pollution and their distribution according to presence of elements in the soils over the whole zone of the province of Maysan in southern of Iraq were investigated 36 soil samples from different zones: residential, industrial, commercial, agricultural and main roads, were collected from the soil surface and a depth of 30 cm and analyzed measuring of concentrations for heavy metals by a device ICP-MS technique. The results were compared with global standard levels of these elements in the soil.

View Publication Preview PDF