Preferred Language
Articles
/
UIb4poYBIXToZYALspw4
Thermal and flow performance analysis of a concentrated linear Fresnel solar collector with transverse ribs
...Show More Authors

This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain absorber tube. Also, the inclusion of transverse ribs inside the absorber tube increases the average Nusselt number by approximately 115% at Re = 5,000 and 175% at Re = 13,000. For all Reynolds numbers, the skin friction coefficient of the circular tube with ribs in the CLFRC system is larger than that of the plain absorber tube. The coefficient of surface friction reduces as the Reynolds number increases. The performance assessment criterion was found to vary between 1.8 and 1.9 as the Reynolds number increases.

Scopus Clarivate Crossref
Publication Date
Wed Mar 01 2017
Journal Name
International Journal Of Cardiology
The role of myocardial performance index in assessment of left ventricular function in patients with valvular mitral regurgitation
...Show More Authors

Background: Mitral regurgitation (MR) is the most commonly encountered valve lesion in modern clinical practice. Severe mitral regurgitation may cause systolic dysfunction. Left ventricular ejection fraction may not be an accurate measurement of LV function in patients with mitral insufficiency. Myocardial performance index (MPI) is a simple non invasive measure of myocardial function. Methods: The study involved 50 patients with valvular mitral regurgitation and 50 healthy subjects as a control group. Transthoracic echocardiography was carried out for all patients and control group. The echocardiographic measurements included left ventricular end diastolic and end systolic dimensions, left atrial diameter, ejection fraction (EF), and myoca

... Show More
View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Fri Nov 25 2022
Journal Name
Diagnostics
Biochemical and Mechanical Analysis of Occlusal and Proximal Carious Lesions
...Show More Authors

A precise evaluation of caries excavation endpoint is essential in clinical and laboratory investigations. Caries invasion differentiates dentin into structurally altered layers. This study assessed these changes using Raman spectroscopy and Vickers microhardness. Ten permanent molars with occlusal and proximal carious lesions were assessed and compared at 130 points utilizing four Raman spectroscopic peaks: phosphate v1 at 960 cm−1, amide I (1650 cm−1), amide III (1235 cm−1) and the C-H bond of the pyrrolidine ring (1450 cm−1). The phosphate-to-amide I peak ratio and collagen integrity peak ratio (amide III: C-H bond) of carious zones were calculated and compared in both lesions. The former ratio was correlated to 130 Vicke

... Show More
View Publication Preview PDF
Scopus (10)
Crossref (11)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2018
Journal Name
Iraqi Journal Of Physics
The influence of argon gas flow in the killing of staphylococcus epidermidis bacteria
...Show More Authors

In this research, non-thermal plasma system of argon gas is designed to work at normal atmospheric pressure and suitable for work in medical and biotechnological applications. This technique is applied in the treatment of the Staphylococcus epidermidis bacteria and show the role of the flow rate of Argon gas on the killing rate of bacteria, and it obtained a 100 % killing rate during the time of 5 minutes at the flow Argon gas of 5 liters/ min.

View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sun Mar 04 2018
Journal Name
Baghdad Science Journal
Effects of Gas Flow on Spectral Properties of Plasma Jet Induced by Microwave
...Show More Authors

In this paper, a construction microwave induced plasma jet(MIPJ) system was used to produce a non-thermal plasma jet at atmospheric pressure, at standard frequency of 2.45 GHz and microwave power of 800 W. The working gas Argon (Ar) was supplied to flow through the torch with adjustable flow rate using flow meter regulator. The influence of the MIPJ parameters such as applied voltage and argon gas flow rate on macroscopic microwave plasma parameters were studied. The macroscopic parameters results show increasing of microwave plasma jet length with increasing of applied voltage, argon gas flow rate where the plasma jet length exceed 12 cm as maximum value. While the increasing of argon gas flow rate will cause increasing into the ar

... Show More
View Publication Preview PDF
Scopus (16)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Mar 18 2021
Journal Name
Review Of International Geographical Education Online
Chomsky's Political Views as a Case Study in a Critical Discourse Analysis of Ideology in the Iraqi Wars
...Show More Authors

APDBN Rashid, Review of International Geographical Education Online (RIGEO), 2021

View Publication
Publication Date
Wed Dec 01 2021
Journal Name
Baghdad Science Journal
Useing the Hierarchical Cluster Analysis and Fuzzy Cluster Analysis Methods for Classification of Some Hospitals in Basra
...Show More Authors

In general, the importance of cluster analysis is that one can evaluate elements by clustering multiple homogeneous data; the main objective of this analysis is to collect the elements of a single, homogeneous group into different divisions, depending on many variables. This method of analysis is used to reduce data, generate hypotheses and test them, as well as predict and match models. The research aims to evaluate the fuzzy cluster analysis, which is a special case of cluster analysis, as well as to compare the two methods—classical and fuzzy cluster analysis. The research topic has been allocated to the government and private hospitals. The sampling for this research was comprised of 288 patients being treated in 10 hospitals. As t

... Show More
View Publication Preview PDF
Scopus (6)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Tue Oct 23 2018
Journal Name
Journal Of Economics And Administrative Sciences
Processing of missing values in survey data using Principal Component Analysis and probabilistic Principal Component Analysis methods
...Show More Authors

The idea of ​​carrying out research on incomplete data came from the circumstances of our dear country and the horrors of war, which resulted in the missing of many important data and in all aspects of economic, natural, health, scientific life, etc.,. The reasons for the missing are different, including what is outside the will of the concerned or be the will of the concerned, which is planned for that because of the cost or risk or because of the lack of possibilities for inspection. The missing data in this study were processed using Principal Component  Analysis and self-organizing map methods using simulation. The variables of child health and variables affecting children's health were taken into account: breastfeed

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Jan 01 2013
Journal Name
كلية التربية الجامعة المستنصرية
Study the electron drift velocity in gas mixtures of CF3I with N2 obtained from Boltzmann equation analysis
...Show More Authors

Publication Date
Wed Jan 01 2014
Journal Name
كلية التربية -الجامعة المستنصرية
study the electron drift velocity in gas mixtures of SF6 with N2 obtained from Boltzmann equation analysis
...Show More Authors

Publication Date
Fri Sep 30 2011
Journal Name
Al-khwarizmi Engineering Journal
Steady State Performance Investigation of a Three Phase Induction Motor Running Off Unbalanced Supply Voltages
...Show More Authors

The objective of this work is to investigate the performance of a conventional three phase induction motor supplied by unbalanced voltages. An effort to study the motor steady state performance under this disturbance is introduced. Using per phase equivalent circuit analysis with the concept of symmetrical components approach, the steady state performance is theoretically calculated. Also, a model for the induction motor with the MATLAB/Simulink SPS tools has been implemented and steady state results were obtained. Both results are compared and show good correlation as well. The simulation model is introduced to support and enhance electrical engineers with a complete understanding for the steady state performance of a fully loaded induc

... Show More
View Publication Preview PDF