Introduction: Infection control or hospital-acquired infections are the major concern of the health care system and agencies. Critical care nurses are on the first-line contact with the patients, so on, they are most vulnerable to acquired infections. It is really important to regularly check their knowledge and practices concerning infection control. Objectives: The study aims to identify the impact of years’ experience on nurses’ knowledge and practices concerning infection control in three hospitals and center (Baghdad teaching hospital, Ibn Al-Nafees hospital, and Ibn al-Bitar center) Methodology: Cross-sectional study was conducted, the study starting from 4th of July 2020 to 13th of November 2020. Non-probability (purposive) sample was used to select 110 nurses who work at critical care units in three hospitals and center (Baghdad teaching hospital, Ibn Al-Nafees hospital, and Ibn al-Bitar center). The years of experience should no less than one year. The instrument was composed of two parts. Firstly, covers the nurses’ demographic characteristics. Secondly, included self-report questions about nurses’ knowledge and an evaluation sheet concerning nurses’ practices of infection control with 24 questions for knowledge and 12 questions for practices checklist. Results: The study revealed that the nurses’ knowledge toward infection control record 38%, 41%, and 21% for low, moderate, and high knowledge respectively. In comparison, nurses practices record 47%, 42%, and 11% for low, moderate, and high practices respectively. Most of the study sample 62% was females while 38 % of the subject was males. The age group (20-29) takes the highest percentage (38%), In addition, about (27.3%) of the nurses who works in critical care units have 1-5 years of experience. Significant statistical associations were found between nurses knowledge and practice from one hand and years’ experience on the other hands p ? 0.05. Recommendation: Based on this finding, the researcher recommended further studies involve more nurses and other health professionals regarding infection control and highlight the importance of infection control to nurses with (1-5) years’ experience by symposium or teaching programs.
This work presents a novel technique for the detection of oil aging in electrical transformers using a single mode optical fiber sensor based on surface plasmon resonance (SPR). The aging of insulating oil is a critical issue in the maintenance and performance of electrical transformers, as it can lead to reduce insulation properties, increase risk of electrical breakdown, and decrease operational lifespan. Many parameters are calculated in this study in order to examine the efficiency of this sensor like sensitivity (S), signal to noise ratio (SNR), resolution (refractive index unit) and figure of merit (FOM) and the values are for figure of merit is 11.05, the signal to noise ratio is 20.3, the sensitivity is 6.63, and the resolution is 3
... Show MoreThe largest use of x-ray in medical by dentists, employers or persons that needed by patients with specific conditions, lead to higher exposure of x-ray that may cause many diseases. In the present work radiography films have been used in evaluating the efficiency of using unsaturated polyester polymer reinforced with lead oxide (PbO) as shield material for medical x-ray devices, many parameters studied like concentration and thickness that they are increasing the attenuation of x-ray in them. The results show that the attenuation of X-ray increasing with concentration of reinforced material and with thickness, and the optical density decreases with increasing concentration from 0% to 50%, we chose 30% as suitable concentration to increase
... Show MoreDesign and build a center basins new p-type four mirrors were studied its effect on all parameters evaluating the performance of the solar cell silicon in the absence of a cooling system is switched on and noted that the efficiency of the performance Hzzh cell increased from 11.94 to 21 without cooling either with cooling has increased the efficiency of the
In this study, NAC-capped CdTe/CdS/ZnS core/double shell QDs were synthesized in an aqueous medium to investigate their utility in distinguishing normal DNA from mutated DNA extracted from biological samples. Following the interaction between the synthesized QDs with DNA extracted from leukemia cases (represents damaged DNA) and that of healthy donors (represents undamaged DNA), differential fluorescent emission maxima and intensities were observed. It was found that damaged DNA from leukemic cells DNA-QDs conjugates at 585 nm while intact DNA (from healthy subjects) DNA–QDs conjugates at 574 nm. The obtained results from the optical analyses indicate that the prepared QDs could be utilized as probe for detecting disrupted DNA th
... Show MoreThe dangers of (Israel's) integration with Arab countries in the middle east region will threaten the Arab security structure dimension, which the latter makes the Arab regional system vulnerable for distortion due to its nominal and symbolic value which is far from the Arab self and questioning with its effectiveness in comparing with the real capabilities to Arab countries in achieving the common targets. So, how to assess the different problems that began to hit the structure of the Arab regional system? and how to pledge an allegiance after putting forward what is known as the American Deal of the Century for the administration of former US President Donald Trump for making another step toward normalization with (Israel)?. The reveal
... Show MoreIn this work, the synergistic effect of chlorinated rubber (additive I),with zeolite 3A (additive II), zeolite 4A (additive III), and zeolite 5A (additive IV) in (1:1) weight percentage, on the flammability for unsaturated polyester resin was studied in the weight ratios for (3,7,10,13&15%) by preparing films of (130×130×3) mm in diameters. Three standard test methods used to measure were the flame retardation which are; ASTM: D-2863, ASTM: D- 635& ASTM: D-3014. Results obtained from these tests indicated that all of the additives were effective additive IV has the highest efficiency as a flame retardant.