Carpal tunnel syndrome is a neurological disease that presented with paresthesias, pain, and numbness in the hand's median nerve compression. Vitamin D was assumed to affect both electrophysiological &clinical gradings, the study aims to assess the correlation between the deficiency of vitamin D and both electrophysiological and clinical gradings. This study was conducted in Ghazi Alhariri Hospital during the period from the first of November/2020 to the twenty-eighth of February/2021, fifty five individuals were referred to as Carpal tunnel syndrome patients, and compared to (55) control individuals, blood samples were withdrawn from the patients (3ml), centrifuged and kept in the freezer (-20°C) until the time of analysis of vitamin D3, Sensory and motor nerve conduction studies of both median and ulnar nerve were done bilaterally. patients were classified electrophysiologically and clinically into two subgroups (mild to moderate) and (severe) groups. The result showed that the differences are not significant in the gender, BMI and vitamin D of the patients versus the control group (p>0.05), the difference of the electrophysiological parameters was not significant between patients with low vitamin D versus those with normal vitamin D (p value>0.05), there was a significant association between the electrophysiological and clinical grading in addition to a significant association between vitamin D level and the clinical grading. Vitamin D deficiency does not affect the electrophysiological parameters while the clinical grading becomes worse with the decrease in its level. The electrophysiological grading is associated with clinical grading.
Nanoparticles of humic acid and iron oxide were impregnated on the inert sand to produce sorbent for treating groundwater contained of cadmium and copper ions by technology of permeable reactive barrier (PRB). Sewage sludge was the source of the humic acid to prepare the coated sand by humic acid—iron oxide (CSHAIO) sorbent; so, this work is consistent with sustainable development. For 10 mg/L metal concentration, batch tests at speed of 200 rpm signified that the removal efficiencies are greater than 90% at sorbent dosage 0.25 g/ 50 mL, pH 6 and contact time 1 h. The kinetic data was well described by the Pseudo first-order model indicating that physicosorption is the predominant mechanism. The maximum adsorption capacities (qmax) were c
... Show MorePoly (viny1 alcohol) (PVA) of 72000 g mol -1 molar mass was cross linked through cold cast esterification with different mol % of MA and EDTA (10 % , 20 % and 30 % ), and two different mol % mixture of MA l EDTA (20 %/5% and 20%/10% .