Preferred Language
Articles
/
SxaSvosBVTCNdQwCU9pU
Effect of seed weight on stem anatomical characters in white lupine (Lupinus albus L.) cultivars
...Show More Authors

An anatomical study was carried out at the College of Agricultural Engineering Sciences, University of Baghdad, in 2017, on lupine crop (Lupinus albus) as a comparison guide of three seed weights of three lupine cultivars viz. ‘Giza-1’, ‘Giza-2’ and ‘Hamburg’. The nested design was used with four replications. The results showed that cultivars had a significant effect on stem anatomical traits. ‘Hamburg’ cultivar recorded the highest stem diameter, cortex thickness and xylem vascular diameter, while cultivar ‘Giza-1’ recorded the lowest values for the same traits as well as the highest collenchyma layer thickness, vascular bundle thickness, and xylem thickness. Cultivar ‘Giza-2’ recorded the lowest vascular bundle thickness and xylem thickness. The interaction between cultivar and seed weight was significant. ‘Hamburg’ cultivar was superior to both ‘Giza-1’ and ‘Giza-2’ anatomically. ‘Hamburg’ cultivar with lower seed weight was found best for field sowing to get higher yield with lower seed cost.

View Publication Preview PDF
Quick Preview PDF
Publication Date
Thu Mar 12 2020
Journal Name
Al-khwarizmi Engineering Journal
Optimization the Effect of Electrode Material Change on EDM Process Performance Using Taguchi Method
...Show More Authors

Electrical Discharge Machining (EDM) is a widespread Nontraditional Machining (NTM) processes for manufacturing of a complicated geometry or very hard metals parts that are difficult to machine by traditional machining operations. Electrical discharge machining is a material removal (MR) process characterized by using electrical discharge erosion. This paper discusses the optimal parameters of EDM on high-speed steel (HSS) AISI M2 as a workpiece using copper and brass as an electrode. The input parameters used for experimental work are current (10, 24 and 42 A), pulse on time (100, 150 and 200 µs), and pulse off time (4, 12 and 25 µs) that have effect on the material removal rate (MRR), electrode wear rate (EWR) and wear ratio (WR). A

... Show More
View Publication Preview PDF
Publication Date
Wed Jun 15 2022
Journal Name
Journal Of Baghdad College Of Dentistry
Effect of Artificial Aging Test on PEEK CAD/CAM Fabricated Orthodontic Fixed Lingual Retainer
...Show More Authors

Background: The purpose of this study was to evaluate the effect of in vitro long-term simulation of oral conditions on the bond strength of PEEK CAD/CAM lingual retainers.

Material and methods: The sample consisted of 12 PEEK CAD/CAM retainers each composed of 2 centrally perforated 3x4mm pads joined by a connector. They were treated by 98% sulfuric acid for 1 minute and then conditioned with Single Bond Universal and bonded to the lingual surface of premolar teeth by 3M Transbond TM System. Half of the retainers were artificially aged using a 30-day water storage and 5000 thermocycling protocol before bond strength testing to compare with the non-aged specimens.

Results: The artificially aged retainers showed a marginally

... Show More
View Publication Preview PDF
Scopus (11)
Crossref (11)
Scopus Crossref
Publication Date
Wed Jan 01 2025
Journal Name
Iraqi National Journal Of Earth Science (injes)
The Effect of Satellite Image Fusion on the Classification Process by Using Multiple Sensors
...Show More Authors

View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Journal Of Clinical And Experimental Dentistry
The effect of osseodensification on implant stability and bone density: A prospective observational study
...Show More Authors

Background: The aims of this study were to evaluate the effect of implant site preparation in low-density bone using osseodensification method in terms of implant stability changes during the osseous healing period and peri-implant bone density using CBCT. Material and methods: This prospective observational clinical study included 24 patients who received 46 dental implants that were installed in low-density bone using the osseodensification method. CBCT was used to measure the bone density pre- and postoperatively and implant stability was measured using Periotest® immediately after implant insertion and then after 6 weeks and 12 weeks postoperatively. The data were analyzed using paired t-test and the probability value <0.05 was conside

... Show More
View Publication
Scopus (27)
Crossref (31)
Scopus Crossref
Publication Date
Tue Jun 30 2020
Journal Name
Pakistan Journal Of Phytopathology
PROTECTIVE EFFECT OF OLIVE POLYPHENOLS ON WATERMELON AGAINST FUSARIUM OXYSPORUM F. SP. NIVEUM INFECTION
...Show More Authors

View Publication
Scopus (4)
Crossref (1)
Scopus Crossref
Publication Date
Thu Apr 01 2021
Journal Name
Iop Conference Series: Earth And Environmental Science
Effect of Metals ( Au, Ag, and Ni) as Cathode Electrode on Perovskite Solar Cells
...Show More Authors
Abstract<p>Gold, silver and nickel used as electrodes in the fabrication of perovskite solar cell by using thermal evaporation deposition method with direct structure FTO\ TiO<sub>2</sub>\ MAPbI<sub>3</sub>\ spiro-MeOTAD\ metal electrode. The cell efficiency was compared between the electrodes material as a function of time to explaining the effect of these metals electrode on cell performance, X-ray diffraction pattern showed that the samples that contain gold and nickel do not contain a compound indicating the interaction of the metal with the components of the cell or the formation of a new compound, while in the cell containing silver it was found that silver iodide is fo</p> ... Show More
View Publication
Scopus (27)
Crossref (21)
Scopus Crossref
Publication Date
Mon Jan 29 2024
Journal Name
Proceedings Of The International Conference On Research Advances In Engineering And Technology - Itechcet 2022
Effect of length to diameter ratio on column bearing capacity stabilized with sodium silicate
...Show More Authors

The numerical analysis was conducted to studying the influence of length to diameter ratio (L/D) on the behavior of the soil treated with sand columns treated with 8% sodium silicate for both floating and end bearing type by using finite element method (Plaxis 3D Foundation ) for isolated foundation of real dimensions. The analysis’s study indicate that in the floating type the best improvement ratio was achieved at (L/D=8) when using columns with a diameter of (0.5, 0.7), but when using columns with a diameter of 0.3 m, it was noticed that the bearing improvement ratio increases with increasing (L/d). While the results of the analysis for end bearing type show that the higher improvement ratio was achieved at (L/D=4) when using columns w

... Show More
View Publication
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Thu Oct 01 2020
Journal Name
Biochemical & Cellular Archives
TOXOPLASMOSIS, DIABETES AND SOME IMMUNE FACTORS THAT EFFECT ON THE BURDEN OF PATIENTS’ IMMUNITY
...Show More Authors

Scopus (2)
Scopus
Publication Date
Mon Mar 18 2019
Journal Name
Al-khwarizmi Engineering Journal
Effect of optimal shot peening time on fatigue life for aluminum alloy 6061-T651
...Show More Authors

The compressive residual stresses generated by shot peening, is increased in a direct proportional way with shot peening time (SPT). For each metal, there is an optimum shot peening time (O.S.T) which gives the optimum fatigue life. This paper experimentally studied to optimize shot peening time of aluminium alloy 6061-T651 as well as using of and analysis of variance (ANOVA).

Two types of fatigue test specimens’ configuration were used, one without notch (smooth) and the other with a notch radius (1,25mm), each type was shot peened at different time. The (O.S.T) was experimentally estimated  to be 8 minutes reaching the surface stresses at maximum peak of -184.94 MPa.

A response surface methodology (RSM) is presen

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Mon Feb 23 2026
Journal Name
Baghdad Science Journal
Synergistic Effect of Different Ions and Hexadecyltrimethylammonium Bromide on Wettability Alteration for Carbonate Rock
...Show More Authors

Naturally carbonate reservoirs have very low oil recovery efficiency owing to their wettability and tightness of matrix. However, adding surfactant to brine solution can enhance oil recovery by changing the wettability of the carbonate rock surface from oil-wet to water-wet. In the present study, the effects of different brines in the presence of surfactant hexadecyltrimethylammonium bromide (CTAB), on the wettability of carbonate rock were investigated through different characteristics such as surface tension interfacial tension and contact angle. The best concentration of CTAB was investigated at 500 ppm in brine (NaCl) reduced surface tension and interfacial tensions to 42 mN/m and 15 mN/m respectively and prevented reservoir fro

... Show More
View Publication
Scopus Crossref