Preferred Language
Articles
/
ShaxdIcBVTCNdQwC70yt
Evaluation for the Cytotoxic Effect of Exotoxin A Produced by Pseudomonas aeruginosa on Mice by using Cytogenetic Parameters
...Show More Authors

This research was conduct to evaluate the cytotoxic effect of exotoxin A (ETA) produced by Pseudomonas aeruginosa on mice in comparison with (phosphate buffer saline (PBS) as a negative control. The effect of the toxin was measured by employing the cytogenetic analysis which included (the mitotic index (MI), chromosomal aberrations (CAs), micronucleus (MN) and sperm abnormalities) parameters. In order to specify the cytotoxic effect of the toxin, three doses of ETA (125, 250 and 500 ng/ml) were used. Results showed that ETA was found to cause a significant decrease in mitotic index (MI) percentage, while significant increase in micronucleus (MN), chromosomal aberrations (CAs) and sperm abnormalities parameters in compression with control was noticed. These differences were found to be dose degraded

Publication Date
Sun Dec 01 2019
Journal Name
Baghdad Science Journal
Extraction, Purification and Characterization of Peroxidase from Pseudomonas aeruginosa and Utility as Antioxidant and Anticancer
...Show More Authors

        Peroxidase is a class of oxidation-reduction reaction enzyme that is useful for accelerating many oxidative reactions that protect cells from the harmful effects of free radicals. Peroxidase is found in many common sources like plants, animals and microbes and have extensive uses in numerous industries such as industrial, medical and food processing. In this study, P. aeruginosa was harvested to utilize and study its peroxidases. P. aeruginosa was isolated from a burn patient, and the isolate was verified as P. aeruginosa using staining techniques, biochemical assay, morphological, and a sensitivity test. The gram stain and biochemical test result show rod pink gram-ne

... Show More
View Publication Preview PDF
Scopus (3)
Scopus Clarivate Crossref
Publication Date
Wed Sep 21 2022
Journal Name
Biochemical And Cellular Archives
ANTIBIOTIC SUSCEPTIBILITY AND BIOFILM FORMATION OF PSEUDOMONAS AERUGINOSA ISOLATED FROM CLINICAL AND ENVIRONMENTAL HOSPITAL SAMPLES
...Show More Authors

Pseudomonas aeruginosa is a Gram-negative opportunistic pathogen and a model bacterium for studying virulence and bacterial social traits. While it can be isolated in low numbers from a wide variety of environments including soil and water, it can readily be found in almost any human/animal-impacted environment. It is a major cause of illness and death in humans with immunosuppressive and chronic conditions, and infections in these patients are difficult to treat due to a number of antibiotic resistance mechanisms and the organism’s propensity to form multicellular biofilms. One hundred twenty clinical samples and forty hospital environmental samples (various sources) were collected from hospitals in Baghdad city during the period from Oc

... Show More
Publication Date
Mon Jan 01 2018
Journal Name
Research Journal Of Pharmacy And Technology
Evaluation of Hesperidin Protective Effect on Lipopolysaccharide-Induced Inflammation and lipid Peroxidation in BALB/C Mail Mice
...Show More Authors

View Publication
Scopus (6)
Crossref (8)
Scopus Crossref
Publication Date
Mon Jan 01 2018
Journal Name
Research Journal Of Pharmacy And Technology
Evaluation of Hesperidin Protective Effect on Lipopolysaccharide-Induced Inflammation and Lipid Peroxidation in BALB/c male mice
...Show More Authors

View Publication
Scopus (7)
Crossref (3)
Scopus Crossref
Publication Date
Sun Dec 09 2018
Journal Name
Baghdad Science Journal
A Comparative Study on the Electrical Characteristics of Generating Plasma by Using Different Target Sources
...Show More Authors

In this research, the electrical characteristics of glow discharge plasma were studied. Glow discharge plasma generated in a home-made DC magnetron sputtering system, and a DC-power supply of high voltage as input to the discharge electrodes were both utilized. The distance between two electrodes is 4cm. The gas used to produce plasma is argon gas which flows inside the chamber at a rate of 40 sccm. The influence of work function for different target materials (gold, copper, and silver), - 5cm in diameter and around 1mm thickness - different working pressures, and different applied voltages on electrical characteristics (discharge current, discharge potential, and Paschen’s curve) were studied. The results showed that the discharge cur

... Show More
View Publication Preview PDF
Scopus (21)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Tue Oct 01 2013
Journal Name
Journal Of Economics And Administrative Sciences
Comparing Between Shrinkage &Maximum likelihood Method For Estimation Parameters &Reliability Function With 3- Parameter Weibull Distribution By Using Simulation
...Show More Authors

The 3-parameter Weibull distribution is used as a model for failure since this distribution is proper when the failure rate somewhat high in starting operation and these rates will be decreased with increasing time .

In practical side a comparison was made between (Shrinkage and Maximum likelihood) Estimators for parameter and reliability function using simulation , we conclude that the Shrinkage estimators for parameters are better than maximum likelihood estimators but the maximum likelihood estimator for reliability function is the better using statistical measures (MAPE)and (MSE) and for different sample sizes.

Note:- ns : small sample ; nm=median sample

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Feb 03 2022
Journal Name
Biologia
Developing multiplex PCR for the rapid and simultaneous detection of Staphylococcus aureus, Pseudomonas aeruginosa and Klebsiella pneumoniae associated with sheep respiratory tract infections
...Show More Authors

Respiratory tract infections in sheep are among the important health problems that affect all sheep ages around the world. Nine bacterial isolates obtained from sheep with respiratory tract infections were selected to be used in the current study. The isolates included 3 Staphylococcus aureus, 4 Klebsiella pneumoniae, and 2 Pseudomonas aeruginosa. Following the primers design by the Primer3Plus software tool and optimization of the conventional polymerase chain reaction (PCR), the primers were validated for their use in the multiplex PCR experiments. The MFEprimer program was used to check the suitability of the primer set combinations for multiplex PCR. The MFEprimer software was successful in designing the multiplex-PCR experiments and de

... Show More
View Publication
Scopus (4)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Sat Mar 27 2021
Journal Name
مجلة دراسات ويحوث التربية الرياضية
Hypoxic exercises by using (training mask) and its effect on the (PMA) and some physiological indicators and achievement for 1500m runners
...Show More Authors

Hypoxic training, which in turn is one of the methods adopted in sports training methods, especially in activities that depend on the aerobic system in its performance, which includes training with a lack of oxygen by reducing its molecular pressure, since this method targets functional organs and works temporary responses during training and permanent responses After training as an adaptation to these devices as a result of training in this way, the study aimed to identify the effect of hypoxic exercises using the training mask and the extent of the change in some biochemical indicators, in addition to that to identify the effect of these exercises on the indicator of energy expenditure and )VMA) and the achievement of the effectiveness of

... Show More
View Publication Preview PDF
Publication Date
Sat Apr 01 2023
Journal Name
Kuwait Journal Of Science
Evaluate the argon plasma jet parameters by optical emission spectroscopy
...Show More Authors

View Publication Preview PDF
Scopus (24)
Crossref (22)
Scopus Clarivate Crossref
Publication Date
Tue Jan 01 2013
Journal Name
Bio-genetics Journal
Measuring the toxicity of Heat Stable Enterotoxin (a) produced by Enterotoxigenic Escherichia coli on human blood lymphocyte from normal and colorectal cancer patients in vitro
...Show More Authors

This research was conducted to measure the safety of heat stable enterotoxin a (STa) produced by enterotoxigenic Escherichia coli, through studying its toxic effect on human blood lymphocyte, since it showed a promising effect in reducing the proliferation of colorectal cancer cells. the cytogenetic effects of (STa) by using five different concentrations (100, 200, 400, 800 and 1600μg/ml) in comparison with negative (PBS, Phosphate buffer saline) and positive (MMC, Mitomycin C) at concentration of 5μg/ml, controls on human blood lymphocytes obtained from both (10) normal healthy persons and (20) colorectal cancer patients was measured by employing the following parameters: mitotic index, blast index, chromosomal aberrations and micronucle

... Show More