Abstract. Shock chlorination is a well-known practice in swimming pools and domestic wells. One of the limitations for using this technique in drinking water purification facilities is the difficulty of quickly removing high chlorine concentrations in water distribution systems or production facilities. In order to use this method in the drinking water industry a shock de-chlorination method should be introduced for producing microorganism and biocide free water. De-chlorination using natural stagnant aeration (leaving the water to lose the chlorine naturally) is the safest known method if compared with chemical and charcoaling methods. Unfortunately, stagnant aeration is a slow process. Therefore, developing a process for accelerating de-chlorination by aeration would pave the way for using shock de-chlorination in drinking water industry. Forced air bubbling is a possible technique for de-chlorination but there is lack of data supporting such a process. The theory is that air bubbling has the advantages of higher mass transfer area, higher Reynolds number across the bubble water interface, and higher mass transfer concentration gradient as the bubbling presents a continuous stream of fresh bubbles. All of these factors accelerate aeration to various extents. A 20 cm diameter, 1-meter height column provided with air sparger was designed to collect the desired data used in this study. Trichloroisocyanuric acid, sodium hypochlorite and chlorine gas were the three familiar sources of chlorine used to investigate their response to air bubbling. Chlorine gas was the fastest and safest chlorine source to be dechlorinated. It dropped from 200 ppm to 0.02 ppm within 4 minutes or zero ppm within 6 minutes using an air flowrate of 9 l/min. Sodium hypochlorite decreased from 200 ppm to 0.02 ppm within 6 minutes using air flowrate of 9 l/min. Trichloroisocyanuric acid found to be the chlorine source slowest to respond to de-chlorination. It decreased from 200 ppm to 0.02 ppm within 8 minutes using an air flowrate of 9 l/min. Shock de-chlorination by aeration is found to be a promising method that opens up the drinking water industry and could produce microorganism and biocide free drinking water.
Trickle irrigation is one of the most conservative irrigation techniques since it implies supplying water directly on the soil through emitters. Emitters dissipate energy of water at the end of the trickle irrigation system and provide water at emission points. The area wetted by an emitter depends upon the discharge of emitter, soil texture, initial soil water content, and soil permeability. The objectives of this research were to predict water distribution profiles through different soils for different conditions and quantify the distribution profiles in terms of main characteristics of soil and emitter. The wetting patterns were simulated at the end of each hour for a total time of application of 12 hrs, emitter disch
... Show MoreIn this paper, ceramic water filters were produced by using ten mixtures of different ratios of red clay and sawdust under different production conditions. The physical properties of these filters were tested. The production conditions include five press pressures ranged from 10 to 50MPa and a firing schedule having three different final temperatures of 1000, 1070, and 1100˚C. The tests results of the physical properties were used to obtain best compatibility between the hydraulic and the mechanical properties of these filters. Results showed that as the press pressure and the firing temperature are increased, the bulk density and the compressive and bending strengths of the produced filters are increased, while, the porosity and absorp
... Show MoreBasrah is the richest town and the economic capital of Iraq. It suffers from lack of drinking water. This project is a dream to supply drinking water to Basrah citizens within WHO standards. Water should pass sedimentation and filtration stages before interring reverse osmosis unit. The design is carried out using lewaplus2 software. Several parameters should be selected in the design step membrane type, number of stages, number per element in each stage, and the recovery percentage. An optimization is carried out using Minitab ver. 18 for the acceptable limit of TDS and minimum cost and it was found that the optimum conditions were 52% for first stage, the numbers of vessels are 20 for both the first and second stage. In addition,
... Show MoreThis work was conducted to study the extraction of eucalyptus oil from natural plants (Eucalyptus camaldulensis leaves) using water distillation method by Clevenger apparatus. The effects of main operating parameters were studied: time to reach equilibrium, temperature (70 to100°C), solvent to solid ratio (4:1 to 8:1 (v/w)), agitation speed (0 to 900 rpm), and particle size (0.5 to 2.5 cm) of the fresh leaves, to find the best processing conditions for achieving maximum oil yield. The results showed that the agitation speed of 900 rpm, temperature 100° C, with solvent to solid ratio 5:1 (v/w) of particle size 0.5 cm for 160 minute give the highest percentage of oil (46.25 wt.%). The extracted oil was examined by HPLC.
Water represents as a basic intellectual material in the myths of creation and the start of formation, Thus, water has turned into an intellectual material in literary mythological texts in addition to its function in sculptural Mesopotamian sculpture. The research is in three sections: the first section deals with Myth, its concept, peculiarities and types, the second section is about mythological literature, the third section is about the idea of water and mythical literature. The question research question here is that does the idea of water have any impact on mythological literature? And Does it link to sculptural products? The importance of the research is that it shows the human imagination and its relationship to functioni
... Show MoreWater saturation is the most significant characteristic for reservoir characterization in order to assess oil reserves; this paper reviewed the concepts and applications of both classic and new approaches to determine water saturation. so, this work guides the reader to realize and distinguish between various strategies to obtain an appropriate water saturation value from electrical logging in both resistivity and dielectric has been studied, and the most well-known models in clean and shaly formation have been demonstrated. The Nuclear Magnetic Resonance in conventional and nonconventional reservoirs has been reviewed and understood as the major feature of this approach to estimate Water Saturation based on T2 distribution. Artific
... Show More