Preferred Language
Articles
/
RhdjWJMBVTCNdQwCdtEh
A Multimodality Hybrid Gamma-Optical Camera for Intraoperative Imaging
...Show More Authors

The development of low profile gamma-ray detectors has encouraged the production of small field of view (SFOV) hand-held imaging devices for use at the patient bedside and in operating theatres. Early development of these SFOV cameras was focussed on a single modality—gamma ray imaging. Recently, a hybrid system—gamma plus optical imaging—has been developed. This combination of optical and gamma cameras enables high spatial resolution multi-modal imaging, giving a superimposed scintigraphic and optical image. Hybrid imaging offers new possibilities for assisting clinicians and surgeons in localising the site of uptake in procedures such as sentinel node detection. The hybrid camera concept can be extended to a multimodal detector design which can offer stereoscopic images, depth estimation of gamma-emitting sources, and simultaneous gamma and fluorescence imaging. Recent improvements to the hybrid camera have been used to produce dual-modality images in both laboratory simulations and in the clinic. Hybrid imaging of a patient who underwent thyroid scintigraphy is reported. In addition, we present data which shows that the hybrid camera concept can be extended to estimate the position and depth of radionuclide distribution within an object and also report the first combined gamma and Near-Infrared (NIR) fluorescence images.

Scopus Clarivate Crossref
View Publication
Publication Date
Thu Jun 30 2016
Journal Name
Al-kindy College Medical Journal
Joubert Syndrome: Imaging Findings and Report of a Case
...Show More Authors

Background: Joubert syndrome (JS) is a very rare autosomal recessive disorder characterized by agenesis of cerebellar vermis, abnormal eye movements, respiratory irregularities, and delayed generalized motor development. Retinal dystrophy and cystic kidneys may also be associated with this clinical syndrome. The importance of recognizing JS is related to the outcome and its potential complications. This syndrome is difficult to diagnose clinically because of its variable phenotype. Its neuroimaging hallmarks include the characteristic molar tooth sign and bat wing-shaped fourth ventricle

View Publication Preview PDF
Publication Date
Thu Oct 12 2023
Journal Name
Mustansiriyah Journal Of Pure And Applied Sciences
Cavitation microbubbles in the medical ultrasound imaging: A Review
...Show More Authors

Ultrasound is a mechanical energy which can generate altering zones of compression and rarefaction along its path in the tissues. Ultrasound imaging can provide a real time screening for blood and multiple organs to aiding the diagnostic and treatment. However, ultrasound has the potential to deposit energy in the blood and tissues causing bio effects which is depending on ultrasound characteristics that including frequency and the amount of intensity. These bio effects include either a stable cavitation presented non thermal effects or inertial cavitation of harmful effect on the tissues. The non-thermal cavitation can add features in diagnostic imaging and treatment more than the inertial cavitation. Ultrasound Contrast agents are a micro

... Show More
Publication Date
Tue Mar 25 2014
Journal Name
Sensors
Minimal Camera Networks for 3D Image Based Modeling of Cultural Heritage Objects
...Show More Authors

View Publication
Scopus (39)
Crossref (29)
Scopus Clarivate Crossref
Publication Date
Thu Jun 30 2022
Journal Name
Iraqi Journal Of Laser
PDF Tunable Optical filters Using Etched Polarization Maintaining Fiber Hybrid Sagnac Interferometer
...Show More Authors

: In modern optical communication system, noise rejection multiple access interference (MAI) must be rejected in dense access network (DAN). This paper will study the dual optical band pass and notch filters. They will be extracted with tunable FWHM using 10cm (PMF) with different cladding diameters formed with etching 125μm PMF after immersing it with 40% of hydrofluoric acid (HF). This fiber acts as assessing fiber to perform Sagnac interferometer with splicing regions that placed 12cm (SMF) for performing hybrid Sagnac interferometer that consists of Mach-Zehnder instead of Sagnac loop which is illuminated by using laser source with centroid wavelength of 1546.7nm and FWHM of 286 pm or 9 ns in the time domain. . Firs

... Show More
View Publication Preview PDF
Publication Date
Thu Jun 15 2023
Journal Name
Romanian Neurosurgery
Delayed intraoperative rupture of clipped aneurysm during the awaking from anaesthesia
...Show More Authors

Introduction. Intraoperative rupture (IOR) of an aneurysm is a frightful complication that causes significant morbidity and mortality worldwide. IOR can be attributed to various parameters, including hypertension, increased intracranial pressure (ICP), fragility of the vessels, and inadequate anaesthesia. IOR due to insufficient anaesthesia is scarcely reported in the literature. Here, we describe a re-ruptured anterior communicating artery (ACoA) after incomplete clipping of the neck during craniotomy closure due to unintended early wake-up from anaesthesia with a discussion about the management. Case description. A 38-year-old male suddenly developed a severe headache, a brief loss of consciousness, and vomiting. Computed tomogr

... Show More
View Publication Preview PDF
Crossref
Publication Date
Fri Jan 01 2016
Journal Name
Advances In Computing
A New Abnormality Detection Approach for T1-Weighted Magnetic Resonance Imaging Brain Slices Using Three Planes
...Show More Authors

Generally, radiologists analyse the Magnetic Resonance Imaging (MRI) by visual inspection to detect and identify the presence of tumour or abnormal tissue in brain MR images. The huge number of such MR images makes this visual interpretation process, not only laborious and expensive but often erroneous. Furthermore, the human eye and brain sensitivity to elucidate such images gets reduced with the increase of number of cases, especially when only some slices contain information of the affected area. Therefore, an automated system for the analysis and classification of MR images is mandatory. In this paper, we propose a new method for abnormality detection from T1-Weighted MRI of human head scans using three planes, including axial plane, co

... Show More
Publication Date
Fri Sep 01 2023
Journal Name
Iraqi Journal Of Physics
Study of the Structural, Optical, and Morphological Properties of SnO2 Nanofilms under the Influence of Gamma Rays
...Show More Authors

This study reports the fabrication of tin oxide (SnO2) thin films using pulsed laser deposition (PLD). The effect of 60Co (300, 900, and 1200 Gy) gamma radiation on the structural, morphological, and optical features is systematically demonstrated using X-ray diffraction (XRD), field emission scanning electron microscopy (FE-SEM), atomic force microscopy (AFM), and ultraviolet-visible light analysis (UV-Vis), respectively In XRD tests, the size of the crystallites decreased from 45.5 to 40.8 nm for the control samples and from 1200 Gy to 60Co for the irradiated samples. Using FESEM analysis, the particle diameter revealed a similar trend to that attained using XRD; in particular, the average diameters were 93.8 and

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Jan 15 2015
Journal Name
مجلة كلية التربية-المؤتمر العلمي التخصصي لكلية التربية
Investigation the Effect of Irradiation by Gamma-Ray on the Structural and Optical Properties of (CIGS) Films
...Show More Authors

Publication Date
Fri Feb 08 2019
Journal Name
Iraqi Journal Of Laser
Photoacoustic Imaging for Tumor Detection: An in vitro Simulation Study
...Show More Authors

Photoacoustic is a unique imaging method that combines the absorption contrast of light or radio frequency waves with ultrasound resolution. When the deposition of this energy is sufficiently short, a thermo-elastic expansion takes place whereby acoustic waves are generated. These waves can be recorded and stored to construct an image. This work presents experimental procedure of laser photoacoustic two dimensional imaging to detect tumor embedded within normal tissue. The experimental work is accomplished using phantoms that are sandwiched from fish heart or blood sac (simulating a tumor) 1-14mm mean diameter embedded within chicken breast to simulate a real tissue. Nd: YAG laser of 1.064μm and 532nm wavelengths, 10ns pulse duration, 4

... Show More
View Publication Preview PDF
Publication Date
Mon Jan 18 2016
Journal Name
Publications Of The Astronomical Society Of The Pacific
Extreme Contrast Ratio Imaging of Sirius with a Charge Injection Device
...Show More Authors

View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref