Preferred Language
Articles
/
RRYZ-IoBVTCNdQwCg8bw
Removal of copper by Azolla filiculoides and Lemna minor: phytoremediation potential, adsorption kinetics and isotherms
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Jun 19 2023
Journal Name
Journal Of Engineering
Detection and Removal of Polycyclic Aromatic Hydrocarbon from Selected Areas in Tigris River in Baghdad City
...Show More Authors

Aromatic hydrocarbons present in Iraqi national surface water were believed to be raised principally from combustion of various petroleum products, industrial processes and transport output and their precipitation on surface water.
Polycyclic aromatic hydrocarbons (PAHs) were included in the priority pollutant list due to their toxic and carcinogenic nature. The concern about water contamination and the consequent human exposure have encouraged the development of new methods for
PAHs detection and removal.
PAHs, the real contaminants of petroleum matter, were detected in selected sites along Tigris River within Baghdad City in summer and winter time, using Shimadzu high performance liquid chromatography (HPLC) system.
Analysi

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Apr 10 2017
Journal Name
Al-mustansiriyah Journal Of Science
Synthesis, characterization and antibacterial Evaluation for mixed-ligand Complexes of Nickle (II), Manganese(II), Copper( II),Cobalt(II) and Mercury(II) with Tetradentate Schiff base and 1,10-phenanthroline
...Show More Authors

An abstract is a brief summary of a research article, thesis, Schiff base ligand (L) was prepared by the reaction of 4-aminantipyrine with o-phenylenediamine, the prepared ligand characterized by Micro elemental Analysis, FT. IR, UV-Vis, and 1H,13C-NMR spectroscopy.complexes of Mn(II), Co(II), Ni(II), Cu(II) and Hg(II) with Schiff base and 1,10-phenanthroline (Phen) have been investigated in aqueous ethanol with (1:1:1) (M:L:Phen). The prepared complexes were characterized using flame atomic absorption, (C. H. N) Analysis, FT. IR and UV-Vis spectroscopic methods as well as magnetic susceptibility and conductivity measurements. From the obtained data the octahedral structure was suggested for all complexes. The biological screening effects o

... Show More
Publication Date
Fri Nov 05 2021
Journal Name
Semiconductor Science And Information Devices
Cladding Modified Fiber Bragg Grating for Copper Ions Detection
...Show More Authors

This paper reports a fiber Bragg grating (FBG) as a biosensor. The FBGs were etched using a chemical agent,namely,hydrofluoric acid (HF). This implies the removal of some part of the cladding layer. Consequently, the evanescent field propagating out of the core will be closer to the environment and become more sensitive to the change in the surrounding. The proposed FBG sensor was utilized to detect toxic heavy metal ions aqueous medium namely, copper ions (Cu2+). Two FBG sensors were etched with 20 and 40 μm diameters and fabricated. The sensors were studied towards Cu2+ with different concentrations using wavelength shift as a result of the interaction between the evanescent field and copper ions. The FBG sensors showed

... Show More
View Publication
Crossref (1)
Crossref
Publication Date
Tue Jan 01 2019
Journal Name
Journal Of International Oral Health
Endothelin-1 is a surrogate biomarker link severe periodontitis and endothelial dysfunction in hypertensive patients: The potential nexus
...Show More Authors

Aim and Objectives: The objective of this study was to illustrate the link between periodontitis (PO) and endothelial dysfunction in hypertensive patients. Materials and Methods: This cross‑sectional study involved 53 hypertensive patients with or without PO compared with 28 healthy controls. On the basis of the study protocol, the participants were divided into three groups: Group (1): 24 patients with hypertension only, Group (2): 29 patients with hypertension and PO, and Group (3): 28 healthy controls. Lipid profile, endothelin‑1 (ET‑1), and high‑sensitivity C‑reactive protein (hs‑CRP) were measured. Blood pressure and body mass index (BMI) were evaluated. Diagnostic criteria of severe PO periodontal indices including plaque

... Show More
View Publication
Scopus (19)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Jan 04 2021
Journal Name
Geofluids
Performance Evaluation of Polyethersulfone Membranes for Competitive Removal of Cd2+, Co2+, and Pb2+ Ions from Simulated Groundwater
...Show More Authors

This paper presents studying the performance of three types of polyethersulfone (PES) membrane for the simultaneous removal of Co2+ ions, Cd2+ ions, and Pb2+ ions from binary and ternary aqueous solutions. Co2+ ions, Cd2+ ions, and Pb2+ ions with two different initial concentrations (e.g., 10 and 50 ppm) were selected as examples of heavy metals that contaminate the groundwater as a result of geological and human activities. This study investigated the effect of types of PES membrane and metal ions concentration on the separation process. For the binary aqueous solutions, the permeation flux of the PES2 membranes was higher for the separation process of solutions containing 50 ppm of Cd2+ ions and 10 ppm of Co2+ ions (24.7 L

... Show More
View Publication
Scopus (19)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon May 01 2023
Journal Name
Journal Of Engineering
Parametric Analysis of Surface Roughness and Metal Removal Rate during Electrical Discharge Machining of O1 Tool Steel
...Show More Authors

This work studies the impact of input machining parameters of Electrical Discharge Machining (EDM) on the machining process performance. Tool steel O1 was selected as the workpiece material, copper as the electrode material, and kerosene as the dielectric medium. Experimental runs have been carried out with a Design of Experiment (DOE) technique. Twenty tests are accomplished with the current range of (18 to 24 Ampere), a pulse duration range of (150 to 200 µs), and a pulse-off time range of (25 to 75 µs). Based upon the experimental study's output results, the EDM parameter's effect (voltage of power supply, discharge current, pulse duration, and pulse pause interval) on the responses of the process represented by sur

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Jan 01 2020
Journal Name
Aip Conf. Proc.
Removal of chromium ions from a real wastewater of leather industry using electrocoagulation and reverse osmosis processes
...Show More Authors

This study focused on treatment of real wastewater rejected from leather industry in Al-Nahrawan city in Iraq by Electrocoagulation (EC) process followed by Reverse Osmosis (RO) process. The successive treatment was applied due to high concentration of Cr3+ ions (about 1600 ppm) rejected in wastewater of this industry and for applying EC with moderate power consumption and better results of produced water. In Electrocoagulation process (EC), the effect of NaCl concentration (1.5, 3 g/l), current density (C.D.) (15-25 mA/cm2), electrolysis time (1-2 h), and distance between electrodes (E.D.) (1-2 cm) were examined in a batch cell by implementing Taguchi experimental design. According to the results obtained from multiple regression and signa

... Show More
View Publication Preview PDF
Scopus (20)
Crossref (16)
Scopus Crossref
Publication Date
Tue Dec 30 2008
Journal Name
Al-kindy College Medical Journal
Evaluation of the Potential Role of Serum Selenium in Diabetic Patients
...Show More Authors

Background: The altered status of some essential trace elements observed in diabetes could have deleterious influences on the health of the diabetics. Objectives: To estimate and study the potential role of serum Selenium in type 1, type 2 diabetics and healthy subjects; and its relation with lipid profile and glycemic index. Methods: A case control designed study was carried out at the National Diabetes Center (NDC) / Al-Mustansiria University; on a total of 94 participants formed of 32 type 1 diabetics, 32 type 2 diabetics and 30 healthy control participants. Data collected about age, sex and BMI; also, blood samples examined for FPG, HbA1C, serum total cholesterol, HDL cholesterol, non-HDL cholesterol, serum triglyceride and sera were

... Show More
View Publication Preview PDF
Publication Date
Sun Jan 01 2017
Journal Name
Proceedings - European Metallurgical Conference, Emc 2017
Friction stir welding of aluminum alloy AA2024-T351 with OFHC copper
...Show More Authors

Scopus
Publication Date
Mon Apr 01 2013
Journal Name
International Journal Of Drug Development And Research
Therapeutic potential effects of pyridoxine and /or ascorbic acid on microalbuminuria in diabetes mellitus patient's: A randomized controlled clinical study
...Show More Authors

Objectives: This study aimed to evaluate the therapeutic potential effects of ascorbic acid or and pyridoxine on diabetic renal microalbumiuria. Methods: This was a cross-sectional study on patients with diabetes mellitus at Al-Yarmouk teaching hospital from January to December 2012, Iraq-Baghdad. Twenty one patients with diabetes mellitus (D.M), 8 IDDM and 13 IDDM were selected from, the duration of disease were ranged from 2-12 years for both type (10 females and 11males) and all enrolled patients ages were ranged from 28-65years. The concentration of total protein in urine was calculated by a biuret colorimetric assay and the urine creatinine level was measured by a modified Jaffe test. Statistical analysis: results are expressed as mean

... Show More
Scopus (4)
Scopus