Preferred Language
Articles
/
QxcYQY4BVTCNdQwC6j_Y
Effects of GFRP Stirrup Spacing on the Behavior of Doubly GFRP-Reinforced Concrete Beams
...Show More Authors

This study investigates the impact of varying glass fiber-reinforced polymer (GFRP) stirrup spacing on the performance of doubly GFRP-reinforced concrete beams. The research focuses on assessing the behavior of GFRP-reinforced concrete beams, including load-carrying capacity, cracking, and deformability. It explores the feasibility and effectiveness of GFRP bars as an alternative to traditional steel reinforcement in concrete structures. Six concrete beams with a cross-section of 300 mm (wide) × 250 mm (deep), simply supported on a 2100 mm span, were tested. The beams underwent four-point bending with two concentrated loads applied symmetrically at one-third of the span length, resulting in a shear span (a)-to-depth (h) ratio of 2.8. The experimental findings reveal that altering the GFRP stirrup spacing along the longitudinal axis of the beams, from 200 mm (equivalent to the effective depth (d)) to 50 mm (equal to (d⁄4)), altered the mode of failure from flexure-shear to flexure-compression. However, when the spacing was equal to or less than (d⁄3), there was no significant improvement in load-carrying capacity, as the contribution of GFRP bars in resisting shear loads was limited. Under service loads, the GFRP-reinforced beams exhibited wider cracks, but reducing the stirrup spacing helped restrain crack widening. Incorporating GFRP bars in the compression zone had a positive effect on reducing crack width in the tension zone. Additionally, using GFRP stirrups with spacing varying between (d) and (d⁄2) in the pure bending region increased the deflection ductility indexes. To enhance the ductility of GFRP-reinforced concrete beams, it is recommended to use GFRP stirrups in the pure bending region with spacing greater than the spacing between GFRP stirrups in the shear spans. The study highlights that the current ACI code overestimates the shear capacity provided by GFRP stirrups, particularly when the spacing is less than or equal to (d⁄3). Doi: 10.28991/CEJ-2024-010-02-011 Full Text: PDF

Scopus Clarivate Crossref
View Publication
Publication Date
Mon Aug 05 2024
Journal Name
Food And Bioprocess Technology
Development of an Innovative Reinforced Food Packaging Film Based on Corn Starch/Hydroxypropyl Methylcellulose/Nanocrystalline Cellulose Incorporated with Nanogel Containing Quercetin
...Show More Authors

View Publication
Scopus (9)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Sun Oct 01 2023
Journal Name
History Of Medicine
Study of the quality of attach algae to the concrete supports of some bridges within Baghdad city
...Show More Authors

A study of taxonomic quality of algae attaching Three concert bridges built on the Tigris River within city of Baghdad including Al-Jadriyah Bridge in Al-Jadriyah area and the Bab Al-Mu'adam Bridge in Al-Shalajiya area, while the third site included Al-Muthanna Bridge in north of Baghdad city, for the period from Autumn 2021 and Winter 2022. The study identified 114 species of 32 Genus in which the predominance of Bacillariophceae (74 species, 14 Genus) Followed by Cyanophyceae (30species, 12 Genus) and 10 species (6 Genus) of Chlorophyceae. The study showed an increase in species of Bacillariophceae, Cyanophyceae which has the ability to secretion gelatinous substances that enable it to stick to solid stand, the number of the larges

... Show More
Preview PDF
Publication Date
Tue Jun 10 2025
Journal Name
Steel And Composite Structures
Flexural behaviour of prefabricated demountable composite beams with LockBolt shear connectors for accelerated construction
...Show More Authors

To promote sustainable steel-concrete composite structures, it is essential to develop special shear connectors that facilitate accelerated construction and deconstruction. A lockbolt demountable shear connector (LBDSC) was recently proposed. While the LBDSC has been evaluated using horizontal and vertical (standard) push-out tests, it is essential to further assess the disassembly mechanism and the positive flexural performance of prefabricated demountable composite beams (PDCBs) under both serviceability and ultimate limit states. Two full-scale test specimens of PDCBs with LBDSC were designed with partial shear connections and assessed using a three or four-point load beam setup under both cyclic and static monotonic loading conditions.

... Show More
Scopus (1)
Scopus
Publication Date
Thu Jan 25 2018
Journal Name
International Journal Of Current Engineering And Technology
Model-Based Design of Piezoelectric Patches used to Repair Damaged Beams under Static Load
...Show More Authors

Static loads exposing to mechanical components can cause cracks, which are lead to form stress concentration regions causing the failure of structure. Generally, from 80% to 90% of structure failure is due to initiation of the cracks. Therefore, it is necessary to repair the crack and reduce its effect on the structure where the effect of the crack is modelled as an additional flexibility to the structure. In the last few years, piezoelectric materials have been considered as one of the most favourable repairing techniques. The piezoelectric material converts the applied voltage on it to a bending moment to counter the bending moment caused by the external load on the beam at the crack location. In this study, the design of the piez

... Show More
View Publication Preview PDF
Crossref
Publication Date
Thu Dec 01 2022
Journal Name
Structural Concrete
Enhancement of RC T‐beams toughness using laced stirrups reinforcement for blast response predictions
...Show More Authors

Publication Date
Wed Dec 28 2022
Journal Name
Structural Concrete
Enhancement of RC T‐beams toughness using laced stirrups reinforcement for blast response predictions
...Show More Authors
Abstract<p>The dynamic behavior of laced reinforced concrete (LRC) T‐beams could give high‐energy absorption capabilities without significantly affecting the cost, which was offered through a combination of high strength and ductile response. In this paper, LRC T‐beams, composed of inclined continuous reinforcement on each side of the beam, were investigated to maintain high deformations as predicted in blast resistance. The beams were tested under four‐point loading to create pure bending zones and obtain the ultimate flexural capacities. Transverse reinforcement using lacing reinforcement and conventional vertical stirrups were compared in terms of deformation, strain, and toughness changes of the tes</p> ... Show More
View Publication
Scopus (7)
Crossref (6)
Scopus Clarivate Crossref
Publication Date
Wed Feb 03 2021
Journal Name
Structural Concrete
Finite element analysis of rectangular RC beams strengthened with FRP laminates under pure torsion
...Show More Authors

Scopus (19)
Crossref (16)
Scopus Clarivate Crossref
Publication Date
Mon Dec 01 2014
Journal Name
Advances In Structural Engineering
CFRP Strengthening of RC Beams with Multiple Openings Subjected to Static and Impact Loads
...Show More Authors

The provision of openings in serviceable reinforced concrete beams may result in a substantial decline in the beam's capacity and integrity, indicating the necessity of opening strengthening. The present study investigates the experimental response of reinforced concrete T-beams with multiple web-strengthened openings disposed in shear span to static and impact loads. Fourteen RC T-beams were tested in two groups, each of seven beams. The first group was tested under static loading up to failure, while the second group was tested under repeated impact loading until the width of shear cracks reached 0.3 mm. The residual static strengths of the beams subjected to impact loading were then determined. The test variables considered were

... Show More
View Publication
Scopus (13)
Crossref (12)
Scopus Clarivate Crossref
Publication Date
Mon Dec 01 2014
Journal Name
Advances In Structural Engineering
CFRP Strengthening of RC Beams with Multiple Openings Subjected to Static and Impact Loads
...Show More Authors

The provision of openings in serviceable reinforced concrete beams may result in a substantial decline in the beam's capacity and integrity, indicating the necessity of opening strengthening. The present study investigates the experimental response of reinforced concrete T-beams with multiple web-strengthened openings disposed in shear span to static and impact loads. Fourteen RC T-beams were tested in two groups, each of seven beams. The first group was tested under static loading up to failure, while the second group was tested under repeated impact loading until the width of shear cracks reached 0.3 mm. The residual static strengths of the beams subjected to impact loading were then determined. The test variables considered were

... Show More
Crossref (12)
Crossref
Publication Date
Fri Mar 15 2024
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the correlation between the tensile and diametrical compression strengths of 3D-printed denture base resin reinforced with ZrO2 nanoparticles
...Show More Authors

Background: The mechanical properties of 3D-printed denture base resins are crucial factors for determining the quality and performance of dentures inside a patient’s mouth. Tensile strength and diametral compressive strength are two properties that could play significant roles in assessing the suitability of a material. Although they measure different aspects of material behavior, a conceptual link exists between them in terms of overall material strength and resilience. Aim: This study aims to investigate the correlation between tensile strength and diametral compressive strength after incorporating 2% ZrO2 nanoparticles (NPs) by weight into 3D-printed denture base resin. Methods: A total of 40 specimens (20 dumbbell-shaped and

... Show More
Scopus (5)
Crossref (2)
Scopus Crossref