Preferred Language
Articles
/
Qob1PIYBIXToZYALhoC8
Determination of Ethanol in Fermented Broth by Headspace Gas Chromatography using Capillary Column
...Show More Authors

The gas chromatography (GC) method in analytical chemistry is a quick and accurate method to detect volatile components like ethanol. A method for determining volatile components known as Headspace chromatography (HS-GC) was developed along with an internal standard method (ISM) to identify ethanol in fermented broth in the laboratory. The aim of this research is determining the concentration of ethanol in fermented broth using capillary column (ZB-1). This method can analyze ethanol concentrations in the fermented medium broth ranging from 10 to 200 g/L. The validation of this method was done in order to obtain the results to be of high precision and the significant, precision was represented as the relative standard deviation (RSD) which was less than 5%, accuracy was less than 4 % and significance level was p [ 0.05. It was found that this method exhibited good reproducibility.

Crossref
Publication Date
Tue Jul 06 2021
Journal Name
Journal Of Ecological Engineering
Chromium Elimination from Contaminated Soil by Electro kinetic Remediation, Using Garlic Peels Powder
...Show More Authors

View Publication
Scopus (7)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Tue Aug 22 2017
Journal Name
Heat Transfer—asian Research
Thermal Enhancement from Pin Fins by Using Elliptical Perforations with Different Inclination Angles
...Show More Authors
Abstract<p>Many of the proposed methods introduce the perforated fin with the straight direction to improve the thermal performance of the heat sink. The innovative form of the perforated fin (with inclination angles) was considered. Present rectangular pin fins consist of elliptical perforations with two models and two cases. The signum function is used for modeling the opposite and the mutable approach of the heat transfer area. To find the general solution, the degenerate hypergeometric equation was used as a new derivative method and then solved by Kummer's series. Two validation methods (previous work and Ansys 16.0‐Steady State Thermal) are considered. The strong agreement of the validation results (0.3</p> ... Show More
View Publication
Scopus (4)
Crossref (5)
Scopus Crossref
Publication Date
Tue Mar 24 2009
Journal Name
كتاب الوقائع /المؤتمر العلمي الثالث لكلية العلوم جامعة بغداد
Using antibiotics as mutagenic and curing agents for Prodigiosin Production By Serratia marcescens
...Show More Authors

The effect of different antibiotics on growth pigment and plasmid curing of Serratia marcescens were studied, S. marcescens was cultured in media containing(16_500)µg/ml of antibiotics, curing mutants unable to produce prodigiosin and lost one plasmid band were obtained of of ampicillin, amoxillin, antibiotics concentrations (64 500) µg/ml metheprim, ultracloxam, azithromycin, cephalexin and erythromycin treated with (350 500) µg/ml of The mutant cells rose- light color and and refampicin revealed S.marcescens inhibited ciprodar and tetracyclin, lincomycin did not lost the plasmid band chlaforan

Publication Date
Sat Dec 31 2016
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
Chromium (VI) Removal from Wastewater by Electrocoagulation Process Using Taguchi Method: Batch Experiments
...Show More Authors

Electrocoagulation is an electrochemical method for treatment of different types of wastewater  whereby sacrificial anodes corrode to release active coagulant (usually aluminium or iron cations) into solution, while simultaneous evolution of hydrogen at the cathode allows for pollutant removal by flotation or settling. The Taguchi method was applied as an experimental design and to determine the best conditions for chromium (VI) removal from wastewater. Various parameters in a batch stirred tank by iron metal electrodes: pH, initial chromium concentration, current density, distance between electrodes and KCl concentration were investigated, and the results have been analyzed using signal-to-noise (S/N) ratio. It was found that the r

... Show More
View Publication Preview PDF
Publication Date
Sun Sep 07 2014
Journal Name
Baghdad Science Journal
An Algorithm for nth Order Intgro-Differential Equations by Using Hermite Wavelets Functions
...Show More Authors

In this paper, the construction of Hermite wavelets functions and their operational matrix of integration is presented. The Hermite wavelets method is applied to solve nth order Volterra integro diferential equations (VIDE) by expanding the unknown functions, as series in terms of Hermite wavelets with unknown coefficients. Finally, two examples are given

View Publication Preview PDF
Crossref
Publication Date
Mon Mar 01 2010
Journal Name
Basrah Journal Of Science
Hiding Three Images at one image by Using Wavelet Coefficients at Color Image
...Show More Authors

Publication Date
Fri Sep 16 2022
Journal Name
Methods In Molecular Biology
Fluorescent Proteins: Crystallization, Structural Determination, and Nonnatural Amino Acid Incorporation
...Show More Authors

View Publication
Scopus Crossref
Publication Date
Sat Feb 15 2025
Journal Name
Iraqi Journal Of Science
Effect of Aluminum Dust Particles on Plasma Parameters at Different Gas Pressure with Different Dust Contents
...Show More Authors

In this work, the effect of aluminum (Al) dust particles on the DC discharge plasma properties in argon was investigated. A magnetron is placed behind the cathode at different pressures and with varying amounts of Al. The plasma temperature (Te) and density (ne) were calculated using the Boltzmann equation and Stark broadening phenomena, which are considered the most important plasma variables through which the other plasma parameters were calculated. The measurements showed that the emission intensity decreases with increasing pressure from 0.06 to 0.4 Torr, and it slightly decreases with the addition of the NPs. The calculations showed that the ne increased and Te decreased with pressure. Both Te and ne were reduced by increasing

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Thu Jun 30 2011
Journal Name
Iraqi Journal Of Chemical And Petroleum Engineering
CORRELATION FOR SOLUTION GAS -OIL RATIO OF IRAQI OILS AT PRESSURES BELOW THE BUBBLE POINT PRESSURE
...Show More Authors

The solution gas-oil ratio is an important measurement in reservoir engineering calculations. The correlations are used when experimental PVT data from particular field are missing. Additional advantages of the correlations are saving of cost and time.
This paper proposes a correlation to calculate the solution gas -oil ratio at pressures below bubble point pressure. It was obtained by multiple linear regression analysis of PVT data collected from many Iraqi fields.
In this study, the solution gas-oil ratio was taken as a function of bubble point pressure, stock tank oil gravity, reservoir pressure, reservoir temperature and relative gas density.
The construction of the new correlation is depending on thirty seven PVT reports th

... Show More
View Publication Preview PDF
Publication Date
Wed Feb 15 2017
Journal Name
Global Journal Of Bio-science And Biotechnology
ISOLATE AND IDENTIFICATION OF PSEUDOMONAS AERUGINOSA FROM CONTAMINATED SOIL WITH HYDROCARBONS DISCHARGED FROM GAS FILLING REFINERIES
...Show More Authors

Petroleum is one of the most important substances consumed by man at present times, a major energy source in this century, petroleum oils can cause environmental pollution during various stages of production, transportation, refining and use, petroleum hydrocarbons pollutions ranging from soil, ground water to marine environment, become an inevitable problem in the modern life, current study focused on bioremediation process of hydrocarbons contaminants that remaining in the bottom of gas cylinders and discharged to the soil. Twenty-four bacterial isolates were isolated from contaminated soils all of them gram negative bacteria, bacterial isolates screening to investigate the ability of biodegradation of hydrocarbons, these isolates inocula

... Show More