Preferred Language
Articles
/
Qhhz5pYBVTCNdQwCuYlH
Study of Adhesion Molecules in Diabetes Mellitus Type2 Iraqi Patients with Dyslipidemia
...Show More Authors

Background: Cell adhesion molecules are protein entities that are located on the cell surface. The vascular cell adhesion molecule-1 (VCAM-1) and intercellular adhesion molecule-1 (ICAM-1) expression is related to type 2 diabetes mellitus (T2DM) with dyslipidemia. Objectives: To determine the levels of VCAM-1 and ICAM-1 in T2DM patients with dyslipidemia and to explore the relationship between VCAM-1 and ICAM-1 and the development of dyslipidemia in T2DM patients. Patients and methods: The study included 150 individuals with an age range of (35-55) years. Patients with diabetes for more than 5 years were excluded. Fifty healthy individuals constituted Group 1 (G1), fifty patients with T2DM constituted Group 2 (G2), and fifty T2DM patients with dyslipidemia constituted Group 3 (G3). Whole blood samples were drawn to measure HbA1c based on fluorescence immunoassay technology. The serum was separated to measure fasting blood glucose (FBG), triglycerides (TG), total cholesterol (TC), and high-density lipoproteins (HDL) by manual methods, while VCAM-1, and ICAM-1 were determined using the ELISA test. The study was conducted between November 2022 and April 2023 at the National Center for Diabetes Treatment and Research, Baghdad, Iraq. Results: Significantly higher levels of FSG and HbA1c were detected in G2 and G3 compared to G1, but non-significantly so when G3 was compared to G2. Significant higher levels of TG and TC levels were detected for G3 when compared to G1 and G2, but non-significantly so when G2 was compared to G1. HDL levels were significantly lower in G3 compared to G2 and G1, but non-significantly so when G2 was compared to G1. VCAM-1, and ICAM-1 were significantly higher in G2 compared to G1, and VCAM-1 level was significantly higher in G3 compared to G2. Non-significant differences in ICAM-1 levels were found between G3 and G2. Conclusion: VCAM-1 and ICAM-1 are potentially significant factors in the development of dyslipidemia in diabetes patients. They might serve as biomarkers to accurately predict the progression of cardiovascular disease.

Scopus Crossref
View Publication
Publication Date
Thu Oct 03 2024
Journal Name
Applied Organometallic Chemistry
Synthesis, Characterization, Molecular Docking, Cytotoxicity, and Antimicrobial Activity of Schiff Base Ligand and Its Metal Complexes
...Show More Authors
ABSTRACT<p>A Schiff base ligand (L) was synthesized via condensation of <italic>N</italic>‐(1‐naphthyl)ethylenediamine dihydrochloride with phthalaldehyde. The ligand was characterized by FT‐IR, UV–Vis, <sup>1</sup>H NMR, mass spectrometry, and elemental analysis (C, H, N). Five metal complexes (Co(II), Ni(II), Cu(II), Zn(II), and Cd(II)) were prepared with the ligand in a 1:1 (M:L) ratio using an aqueous ethanol solution. The complexes were characterized by FT‐IR, UV–Vis, mass spectrometry, and elemental analysis (C, H, N). Additionally, <sup>1</sup>H NMR spectroscopy was employed for Cd(II) complex. Antimicrobial activity of the ligand and its metal complexes against </p> ... Show More
Scopus (11)
Crossref (11)
Scopus Crossref
Publication Date
Wed Apr 01 2020
Journal Name
Isa Transactions
Design of a Complex fractional Order PID controller for a First Order Plus Time Delay system
...Show More Authors

View Publication
Scopus (52)
Crossref (45)
Scopus Clarivate Crossref
Publication Date
Tue Jun 01 2010
Journal Name
Al-khwarizmi Engineering Journal
Comparison of the RLS and LMS Algorithms to Remove Power Line Interference Noise from ECG Signal
...Show More Authors

    Biomedical signal such as ECG is extremely important in the diagnosis of patients and is commonly recorded with a noise. Many different kinds of noise exist in biomedical environment such as Power Line Interference Noise (PLIN). Adaptive filtering is selected to contend with these defects, the adaptive filters can adjust the filter coefficient with the given filter order. The objectives of this paper are: first an application of the Least Mean Square (LMS) algorithm, Second is an application of the Recursive Least Square (RLS) algorithm to remove the PLIN. The LMS and RLS algorithms of the adaptive filter were proposed to adapt the filter order and the filter coefficients simultaneously, the performance of existing LMS

... Show More
View Publication Preview PDF
Publication Date
Thu Dec 01 2022
Journal Name
Baghdad Science Journal
The Approximation of Weighted Hölder Functions by Fourier-Jacobi Polynomials to the Singular Sturm-Liouville Operator
...Show More Authors

      In this work, a weighted H lder function that approximates a Jacobi polynomial which solves the second order singular Sturm-Liouville equation is discussed. This is generally equivalent to the Jacobean translations and the moduli of smoothness. This paper aims to focus on improving methods of approximation and finding the upper and lower estimates for the degree of approximation in weighted H lder spaces by modifying the modulus of continuity and smoothness. Moreover, some properties for the moduli of smoothness with direct and inverse results are considered.

View Publication Preview PDF
Scopus (7)
Crossref (3)
Scopus Clarivate Crossref
Publication Date
Fri May 03 2024
Journal Name
Optical And Quantum Electronics
Design and analysis of a dual-core PCF biosensor based on SPR for cancerous cells detection
...Show More Authors

View Publication
Scopus (35)
Crossref (37)
Scopus Clarivate Crossref
Publication Date
Wed Jun 01 2016
Journal Name
Ieee Transactions On Neural Systems And Rehabilitation Engineering
Improving the Performance Against Force Variation of EMG Controlled Multifunctional Upper-Limb Prostheses for Transradial Amputees
...Show More Authors

View Publication
Scopus (305)
Crossref (271)
Scopus Clarivate Crossref
Publication Date
Sat Feb 01 2020
Journal Name
Journal Of Water Process Engineering
Immobilization of cobalt ions using hierarchically porous 4A zeolite-based carbon composites: Ion-exchange and solidification
...Show More Authors

View Publication
Scopus (65)
Crossref (56)
Scopus Clarivate Crossref
Publication Date
Sun Dec 25 2022
Journal Name
Iraqi Journal Of Pharmaceutical Sciences ( P-issn 1683 - 3597 E-issn 2521 - 3512)
Epicatechin product of Camellia sinensis leaves detection by thin layer chromatography and high performance liquid chromatography
...Show More Authors

The current study performed in order to detect and quantify epicatechin in two tea samples of Camellia sinensis (black and green tea) by thin layer chromatography (TLC) and high performance liquid chromatography (HPLC). Extraction of epicatechin from black and green tea was done by using two different methods: maceration (cold extraction method) and decoction (hot extraction method). Qualitative and quantitative determinations of epicatechin in two tea samples were investigated. Epicatechin identification was made by utilizing preliminary chemical tests and TLC. This identification was also boosted by HPLC and then quantified epicatechin in all ethyl acetate fractions of two tea samples. This research revealed the existence of epica

... Show More
Scopus (2)
Crossref (1)
Scopus Crossref
Publication Date
Tue May 12 2026
Journal Name
International Journal Of Environmental Analytical Chemistry
Eco-friendly chelating Ni(II) nano-compounds for colorimetric optical fiber sensing of heavy metal ions
...Show More Authors

A new Ni(II) nanostructured chelating system (DHN) was introduced for selective optical heavy-metal ion sensing in an aqueous medium. The cooperative chelating system comprising 8-hydroxyquinoline (8-HQ) and dimethylglyoxime (DMG) has been developed for the first time in association with fibre optic sensing for selective optical heavy-metal ion sensing in an aqueous medium. The Ni(II) nanocompound fluoresces upon 578 nm excitation, showing a highly sensitive optical response with a linear calibration curve in the range 0–100 ng/mL. The regression equation of the calibration curve is y = 0.0035x + 0.9990, which indicates very good linearity, implying R2 = 0.999 with high sensitivity (calibration slope of 0.0035) and low baseline noise (bla

... Show More
View Publication
Crossref
Publication Date
Thu Jan 01 2026
Journal Name
Iraqi Journal Of Science
Impact the Some Antibiotic on Gene Expression Efflux Pump of Klebsiella pneumoniae Isolated from Clinical Sources
...Show More Authors