Preferred Language
Articles
/
QhceXpABVTCNdQwC74it
Green methods for determination of paracetamol in drug samples: A comparative study
...Show More Authors

Scopus Clarivate Crossref
View Publication
Publication Date
Sat Oct 28 2023
Journal Name
Baghdad Science Journal
Indirect Flow Injection Spectrophotometric and Chromatographic Methods for the Determination of Mebendazole in Pharmaceutical Formulations
...Show More Authors

Chromatographic and spectrophotometric methods for the estimation of mebendazole in
pharmaceutical products were developed. The flow injection method was based on the oxidation of
mebendazole by a known excess of sodium hypochlorite at pH=9.5. The excess sodium hypochlorite is then
reacted with chloranilic acid (CAA) to bleach out its color. The absorbance of the excess CAA was recorded
at 530 nm. The method is fast, simple, selective, and sensitive. The chromatographic method was carried out
on a Varian C18 column. The mobile phase was a mixture of acetonitrile (ACN), methanol (MeOH), water
and triethylamine (TEA), (56% ACN, 20% MeOH, 23.5% H2O, 0.5% TEA, v/v), adjusted to pH = 3.0 with
1.0 M hy

... Show More
View Publication Preview PDF
Scopus (4)
Crossref (2)
Scopus Crossref
Publication Date
Fri Sep 30 2022
Journal Name
Journal Of Economics And Administrative Sciences
A Comparative Study for Estimate Fractional Parameter of ARFIMA Model
...Show More Authors

      Long memory analysis is one of the most active areas in econometrics and time series where various methods have been introduced to identify and estimate the long memory parameter in partially integrated time series. One of the most common models used to represent time series that have a long memory is the ARFIMA (Auto Regressive Fractional Integration Moving Average Model) which diffs are a fractional number called the fractional parameter. To analyze and determine the ARFIMA model, the fractal parameter must be estimated. There are many methods for fractional parameter estimation. In this research, the estimation methods were divided into indirect methods, where the Hurst parameter is estimated fir

... Show More
View Publication Preview PDF
Crossref
Publication Date
Sun Jun 01 2014
Journal Name
Baghdad Science Journal
Spectrophotometric Analytical method for Determination the Drug Compound Salbutamol by using Prussian blue Complex
...Show More Authors

This research aims to develop new spectrophotometric analytical method to determine drug compound Salbutamol by reaction it with ferric chloride in presence potassium ferricyanide in acid median to formation of Prussian blue complex to determine it by uv-vis spectrophotmetric at wavelengths rang(700-750)nm . Study the optimal experimental condition for determination drug and found the follows: 1- Volume of(10M) H2SO4 to determine of drug is 1.5 ml . 2- Volume and concentration of K3Fe(CN)6 is 1.5 ml ,0.2% . 3- Volume and concentration of FeCl3 is 2.5ml , 0.2%. 4- Temperature has been found 80 . 5- Reaction time is 15 minute . 6- Order of addition is (drug + K3Fe(CN)6+ FeCl3 + acid) . Concentration rang (0.025-5 ppm) , limit detecti

... Show More
View Publication Preview PDF
Crossref
Publication Date
Mon Jun 01 2020
Journal Name
Journal Of Analytical Chemistry
Ion Pair-dispersive Liquid–Liquid Microextraction Combined with Spectrophotometry for Carbamazepine Determination in Pharmaceutical Formulations and Biological Samples
...Show More Authors

A simple, economical and selective method employing ion pair dispersive liquid−liquid microextraction (DLLME) coupled with spectrophotometric determination of carbamazepine (CBZ) in pharmaceutical preparations and biological samples was developed. The method is based on reduction of Mo(VI) to Mo(V) using a combination of ammonium thiocyanate and ascorbic acid in acidic medium to form a red binary Mo(V) thiocyanate complex. After addition of CBZ to the complex, extraction of the formed CBZ−Mo(V)−(SCN)6 was performed using a mixture of methylene chloride and methanol. Then, the measurement of target complex was performed at the wavelength of 470 nm. The important extraction parameters affecting the efficiency of DLLME were studied and o

... Show More
View Publication
Scopus (10)
Crossref (4)
Scopus Clarivate Crossref
Publication Date
Wed Aug 01 2018
Journal Name
Journal Of Economics And Administrative Sciences
A Comparative Study of Some Methods of Estimating Robust Variance Covariance Matrix of the Parameters Estimated by (OLS) in Cross-Sectional Data
...Show More Authors

 

Abstract

The Classical Normal Linear Regression Model Based on Several hypotheses, one of them is Heteroscedasticity as it is known that the wing of least squares method (OLS), under the existence of these two problems make the estimators, lose their desirable properties, in addition the statistical inference becomes unaccepted table. According that we put tow alternative,  the first one is  (Generalized Least Square) Which is denoted by (GLS), and the second alternative is to (Robust covariance matrix estimation) the estimated parameters method(OLS), and that the way (GLS) method neat and certified, if the capabilities (Efficient) and the statistical inference Thread on the basis of an acceptable

... Show More
View Publication Preview PDF
Crossref
Publication Date
Tue Apr 28 2020
Journal Name
Journal Of Law And Humanities Sciences
Fair compensation for expropriation for the public benefit (A comparative study)
...Show More Authors

The right to property is one of the most fundamental rights enjoyed by individuals, and most national constitutions and laws, as well as international conventions, have to be respected and protected only in accordance with the economic and social development of the country (the so-called public benefit) and in return for just compensation. What is fair compensation?

Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
Scopus (5)
Scopus Crossref
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
View Publication
Scopus (5)
Scopus Clarivate Crossref
Publication Date
Fri Jan 10 2025
Journal Name
Chemchemtech
LC-MS/MS METHOD FOR THE DETERMINATION OF IMATINIB MESYLATE IN BLOOD PLASMA SAMPLES AFTER ADSORPTION BY COPPER TANNIC ACID
...Show More Authors

A novel metal-organic framework (MOF) sorbent based on tannic acid/copper (TA/Cu) was synthesized and characterized for the application of the anticancer drug imatinib (IMA) from biological samples. The TA/Cu MOF was prepared via a facile coordination reaction and thoroughly characterized by SEM, XRD, and FTIR techniques. Critical parameters influencing the extraction efficiency of imatinib mesylate (IMAM), including pH, ionic strength, desorption solvent, and adsorption-desorption time were optimized. With acetonitrile as the desorption solvent, the method demonstrated a broad linear range of 0.55-300 μg L-1 under ideal conditions. Limits of detection and quantification were found to be 0.16 μg L-1 and 0.55 μg L-1, respectively.

... Show More
View Publication
Scopus (5)
Scopus Clarivate Crossref
Publication Date
Sun Jun 05 2016
Journal Name
Baghdad Science Journal
Development of an Eco-Friendly Method for Iron Extraction and Determination in Pharmaceuticals Using Ciprofloxacin Drug as Chelating agent
...Show More Authors

A method is developed for the determination of iron (III) in pharmaceutical preparations by coupling cloud point extraction (CPE) and UV-Vis spectrophotometry. The method is based on the reaction of Fe(III) with excess drug ciprofloxacin (CIPRO) in dilute H2SO4, forming a hydrophobic Fe(III)- CIPRO complex which can be extracted into a non-ionic surfactant Triton X-114, and iron ions are determined spectrophotometrically at absorption maximum of 437 nm. Several variables which impact on the extraction and determination of Fe (III) are optimized in order to maximize the extraction efficiency and improve the sensitivity of the method. The interferences study is also considered to check the accuracy of the procedure. The results hav

... Show More
View Publication Preview PDF
Crossref (1)
Crossref