Preferred Language
Articles
/
QReFj5IBVTCNdQwC77cT
Factors affecting on in vitro release of miconazole from in situ ocular gel
...Show More Authors

The reason for conducting this study is to prolong release of miconazole in the ocular site of action by ocular-based gels (OBGs) formulations. The formulation factors affecting on the release from OBG should be studied using various gelling agents in various concentrations to achieve the improvement in retention and residence time in response to prolonged release. In this study, the formulations were prepared using carbopol 940, pectin, sodium alginate, poloxamer 407, and poly(methacrylic acid) at 0.5%, 1%, and 1.5% w/v, respectively. Hydroxypropyl methylcellulose E5 (HPMC E5) 1% was added as thickening agent/viscosity builder. The formulation containing carbopol 940, pectin and sodium alginate at 1.5% w/v, displayed a noticable improvement in viscosity, gelling capacity, and extended release for 7 h in comparison with the reference drug. Overall, the release showed that the sodium alginate with HPMC E5 form in situ gel which had longer time of release reach to 12 h compared with other polymers. the release of miconazole from the OBGs affected significantly by two factors includes gelling capacity and viscosity builder. The novelty of this study is supporting the delivery of ocular drugs through a cornea as an important key of the eye instead of dependence on an internal blood supply using an oral or a parental administration.

Scopus Crossref
View Publication
Publication Date
Mon Jan 01 2024
Journal Name
Journal Of Research In Pharmacy
Preparation and in-vitro evaluation of Carbopol hydrogel of clobetasol-loaded ethylcellulose microsponges
...Show More Authors

: Clobetasol propionate (CP) is a potent corticosteroid used for skin conditions but often causes side effects due its systemic absorption. To improve its solubility and reduce it side effects (like skin irritation, skin atrophy, hypopigmentation and steroidal acne), Microsponge (Msg) has been employed as a unique three-dimensional particle that can encapsulate hydrophilic and lipophilic drugs. This study aims to develop and evaluate CP Msg-loaded hydrogels. Two Clobetasol-loaded ethylcellulose-based Msg formulas were prepared using the quasi-emulsion solvent diffusion method, then they were incorporated into Carbopol hydrogel. Two ratios of Carbopol 940 (1% and 1.5% w/w) were used. The prepared hydrogel were assessed for appearance, pH, dr

... Show More
View Publication
Scopus (1)
Crossref (1)
Scopus Clarivate Crossref
Publication Date
Sat Dec 01 2012
Journal Name
Al Mustansiriyah Journal Of Pharmaceutical Sciences
Formulation and In Vitro Evaluation of Mucoadhesive Antimicrobial Vaginal Tablets of Ciprofloxacin Hydrochloride
...Show More Authors

Ciprofloxacin is a broad spectrum fluoroquinolone, effective in the treatment of a wide range of infections, including genitourinary tract infections.In this study, bioadhesive vaginal tablets of ciprofloxacin hydrochloride were prepared by direct compression method using a combination of bioadhesivepolymers carbopol 934P(Cp), carboxymethylcellulose (CMC) and sodium alginate (SA) in different ratios.The prepared tablet formulations were characterized by measuring their swelling capacity, surface pH, bioadhesive properties, and in-vitro drug dissolution. It was found that the bioadhesive force was directly proportional to carbopol 934P content in different formulae and was further enhanced by the inclusion of carboxymethylcellulose.

... Show More
View Publication Preview PDF
Crossref (1)
Crossref
Publication Date
Sat Jan 01 2011
Journal Name
Journal Of Baghdad College Of Dentistry
Assessment of the accuracy of a fifth generation apex locator (in vitro study)
...Show More Authors

Background: The use of electronic apex locators for working length determination eliminates many of the problems associated with the radiographic measurements (interference of anatomical structures, errors in projection such as elongation or shortening, and lack of three-dimensional representation). Its most important advantage over radiography is that it measures the length of the root canal to the apical constriction, not to the radiographic apex. The aim of this study was to assess the accuracy of a new fifth generation apex locator (Joypex 5) in recording the apical constriction and comparing it with a third generation apex locator (Root ZX) in vitro. Materials and method: Twenty four single-rooted sound human premolars, extracted for t

... Show More
Preview PDF
Publication Date
Thu Sep 10 2026
Journal Name
Journal Of Baghdad College Of Dentistry
In Vitro Evaluation of Shear Bond Strength of Sapphire Brackets after Dental Bleaching
...Show More Authors

Background: The present study was conducted to evaluate the effects of different bleaching methods on the shear bond strength of orthodontic Sapphire brackets bonded to human premolars teeth using light cured composite resin and to determine the predominant site of bond failure. Materials and Methods: Thirty freshly extracted human premolars were selected and randomly divided into three groups (10 per group). These groups are: control (unbleached) group, hydrogen peroxide group (HP) 37.5% ; which is the in- office bleaching method group, carbamide peroxide group (CP) 16%; which is the at- home bleaching method group. After bleaching process was performed, all the teeth stored in distilled water in a sealed container at room temperature for

... Show More
View Publication Preview PDF
Crossref
Publication Date
Wed Aug 30 2023
Journal Name
Al-kindy College Medical Journal
Factors associated with Exacerbation of Myasthenia Gravis in a Group of Iraqi Patients
...Show More Authors

Background: Myasthenia gravis is an autoimmune disease of the neuromuscular junction that results in fluctuating muscle weakness as well as significant fatigue. Disease exacerbation is a critical condition, and the predisposing factors for it need to be identified to improve preventive measures.

Objectives:  Our study aims to determine the predisposing factors for myasthenia gravis exacerbations in a group of Iraqi patients.

Subjects and Methods: A total number of 30 myasthenia gravis patients were admitted to the hospital with an exacerbation of their symptoms, determined as the development of functional disability, dysphagia, or respiratory fai

... Show More
View Publication Preview PDF
Scopus Crossref
Publication Date
Fri Nov 09 2018
Journal Name
Iraqi National Journal Of Nursing Specialties
Assessment of the Risk Factors of Coronary Artery Diseases in Al-Nasiriyah City
...Show More Authors

Objective: to assess the risk factors of coronary artery disease patients.
Methodology: A non-probability (purposive) sample of (100) patients. The study population consisted of
a sample of adults from both genders whose ages were 30 years and more, and was newly diagnosed as
having CAD by coronary angiography in the cardiac catheterization unit of An Nasiriyah heart center.
Results: The result of the study showed that the most common modifiable risk factors were low HDL-C
levels (58%), smoking (53%), hypertension (46%), diabetes mellitus (34%), obesity (30%), high
triglycerides (19%), hypercholesterolemia (17%), and high LDLC (14%). All these factors were positively
and significantly associated with the development

... Show More
View Publication Preview PDF
Publication Date
Sat Jan 05 2019
Journal Name
Iraqi Journal Of Physics
Study the structural and optical properties of titanium oxide thin film, doped with chromium prepared in Sol-Gel method
...Show More Authors

This paper presents the effect of Cr doping on the optical and structural properties of TiO2 films synthesized by sol-gel and deposited by the dip- coating technique. The characteristics of pure and Cr-doped TiO2 were studied by absorption and X-ray diffraction measurement. The spectrum of UV absorption of TiO2 chromium concentrations indicates a red shift; therefore, the energy gap decreases with increased doping. The minimum value of energy gap (2.5 eV) is found at concentration of 4 %. XRD measurements show that the anatase phase is shown for all thin films. Surface morphology measurement by atomic force microscope (AFM) showed that the roughness of thin films decrease with doping and has a minimum value with 4 wt % doping ratio.

View Publication Preview PDF
Crossref (5)
Crossref
Publication Date
Fri Aug 12 2022
Journal Name
Journal Of Research In Medical And Dental Science
Effects of Ozonated Water on Micro Leakage between Enamel and Fissure Sealants Prepared by Different Etching Technique (An in vitro Study)
...Show More Authors

Effects of Ozonated Water on Micro Leakage between Enamel and Fissure Sealants Prepared by Different Etching Technique (An in vitro Study), Baraa M Jabar*, Muna S Khalaf

View Publication Preview PDF
Publication Date
Wed May 01 2024
Journal Name
Journal Of International Society Of Preventive And Community Dentistry
Effect of Incorporating Chitosan to Resin Modified Glass Ionomer Cement on Shear Bond Strength to Dentin (An In vitro Comparative Study)
...Show More Authors
A<sc>bstract</sc> <sec> <title>Aim:

Resin-modified glass ionomer cement tends to shrink due to polymerization of the resin component. Additionally, they are more prone to syneresis and imbibition during the setting process. This in vitro study evaluates the impact of chitosan, a biopolymer that is, both biomaterial and biocompatible, on the strength of dentin bonding and compares it with ACTIVA Bio-ACTIVE Restorative. The present study was aimed to assess the impact of including chitosan into Fuji II on the shear bond strength between. the restoration material and tooth dentin,

... Show More
View Publication
Scopus (5)
Crossref (5)
Scopus Clarivate Crossref
Publication Date
Thu Jul 04 2024
Journal Name
Pharmaceutics
Formulation Development of Meloxicam Binary Ethosomal Hydrogel for Topical Delivery: In Vitro and In Vivo Assessment
...Show More Authors

Abstract: The article aimed to formulate an MLX binary ethosome hydrogel for topical delivery to escalate MLX solubility, facilitate dermal permeation, avoid systemic adverse events, and compare the permeation flux and efficacy with the classical type. MLX ethosomes were prepared using the hot method according to the Box–Behnken experimental design. The formulation was implemented according to 16 design formulas with four center points. Independent variables were (soya lecithin, ethanol, and propylene glycol concentrations) and dependent variables (vesicle size, dispersity index, encapsulation efficiency, and zeta potential). The design suggested the optimized formula (MLX−Ethos−OF) with the highest desirability to perform the

... Show More
Preview PDF
Scopus (13)
Scopus