Preferred Language
Articles
/
QRdyco4BVTCNdQwCpEhf
Impacts of Varied Injection Timing on Emission Levels, Combustion Efficiency, and Performance of Biodiesel Engines
...Show More Authors

Scopus Crossref
View Publication
Publication Date
Mon Jan 04 2021
Journal Name
Geofluids
Performance Evaluation of Polyethersulfone Membranes for Competitive Removal of Cd2+, Co2+, and Pb2+ Ions from Simulated Groundwater
...Show More Authors

This paper presents studying the performance of three types of polyethersulfone (PES) membrane for the simultaneous removal of Co2+ ions, Cd2+ ions, and Pb2+ ions from binary and ternary aqueous solutions. Co2+ ions, Cd2+ ions, and Pb2+ ions with two different initial concentrations (e.g., 10 and 50 ppm) were selected as examples of heavy metals that contaminate the groundwater as a result of geological and human activities. This study investigated the effect of types of PES membrane and metal ions concentration on the separation process. For the binary aqueous solutions, the permeation flux of the PES2 membranes was higher for the separation process of solutions containing 50 ppm of Cd2+ ions and 10 ppm of Co2+ ions (24.7 L

... Show More
View Publication
Scopus (23)
Crossref (14)
Scopus Clarivate Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Applied Energy
Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq
...Show More Authors

View Publication
Scopus (137)
Crossref (119)
Scopus Crossref
Publication Date
Mon Oct 01 2012
Journal Name
Applied Energy
Analysis of thermal and electrical performance of a hybrid (PV/T) air based solar collector for Iraq
...Show More Authors

The electrical and thermal performance of a typical single pass hybrid photovoltaic/thermal (PV/T) air collector is modeled, simulated and analyzed for two selected case studies in Iraq. An improved mathematical thermo-electrical model is derived in terms of design, operating and climatic parameters of the hybrid solar collector to evaluate its important characteristics: collector flow and heat removal factors, PV maximum power point and its temperature coefficient, and overall power and efficiency. Unlike previous PV/T thermal models, the present model is obtained with some additions and corrections in radiation and convection heat coefficients for the top loss and for the air duct with more applicable sky temperature correlation. The well

... Show More
View Publication
Scopus (137)
Crossref (119)
Scopus Crossref
Publication Date
Fri Dec 01 2017
Journal Name
International Journal Of Electrical And Computer Engineering (ijece)
Performance Evaluation of UDP, DCCP, SCTP and TFRC for Different Traffic Flow in Wired Networks
...Show More Authors

<p>The demand for internet applications has increased rapidly.  Providing quality of service (QoS) requirements for varied internet application is a challenging task. One important factor that is significantly affected on the QoS service is the transport layer. The transport layer provides end-to-end data transmission across a network. Currently, the most common transport protocols used by internet application are TCP (Transmission Control Protocol) and UDP (User Datagram Protocol). Also, there are recent transport protocols such as DCCP (data congestion control protocol), SCTP (stream congestion transmission protocol), and TFRC (TCP-friendly rate control), which are in the standardization process of Internet Engineering Task

... Show More
View Publication Preview PDF
Crossref (2)
Crossref
Publication Date
Tue Mar 01 2022
Journal Name
Evergreen
Development, Validation, and Performance Evaluation of An Air-Driven Free-Piston Linear Expander Numerical Model
...Show More Authors

View Publication Preview PDF
Scopus (3)
Scopus Crossref
Publication Date
Sun Jan 01 2012
Journal Name
Journal Of Engineering
DESIGN OF A VARIABLE GAIN NONLINEAR FUZZY CONTROLLER AND PERFORMANCE ENHANCEMENT DUE TO GAIN VARIATION
...Show More Authors

In this paper, variable gain nonlinear PD and PI fuzzy logic controllers are designed and the effect of the variable gain characteristic of these controllers is analyzed to show its contribution in enhancing the performance of the closed loop system over a conventional linear PID controller. Simulation results and time domain performance characteristics show how these fuzzy controllers outperform the conventional PID controller when used to control a nonlinear plant and a plant that has time delay.

Publication Date
Sat Feb 09 2019
Journal Name
Journal Of The College Of Education For Women
١١٦ Academic Specialization and its relationship to job performance of The officials ofBaghdad University Presidency
...Show More Authors

The aims of this research is to investigate : The nature of academic specialization of the officials of Baghdad University Presidency , Level of job performance of the officials of Baghdad University Presidency through job performance appraisal form per year , Differences in the levels of job performance of the officials of Baghdad university presidency , according to the variables (sex , academic specialization , the current work , the duration between the date of graduation and the date of appointment , service duration) , The relationship of academic specialization of the officials of Baghdad university presidencywith their job performance . The researcher has followed the analytical descriptive mode to achieve the aims of this resear

... Show More
View Publication Preview PDF
Publication Date
Wed Jan 04 2023
Journal Name
Frontiers In Chemestry
Thermal and flow performance analysis of a concentrated linear Fresnel solar collector with transverse ribs
...Show More Authors

This article deals with the impact of including transverse ribs within the absorber tube of the concentrated linear Fresnel collector (CLFRC) system with a secondary compound parabolic collector (CPC) on thermal and flow performance coefficients. The enhancement rates of heat transfer due to varying governing parameters were compared and analyzed parametrically at Reynolds numbers in the range 5,000–13,000, employing water as the heat transfer fluid. Simulations were performed to solve the governing equations using the finite volume method (FVM) under various boundary conditions. For all Reynolds numbers, the average Nusselt number in the circular tube in the CLFRC system with ribs was found to be larger than that of the plain abs

... Show More
Scopus (7)
Crossref (7)
Scopus Clarivate Crossref
Publication Date
Thu Jan 01 2015
Journal Name
Health
Evaluation of Myocardial Performance in Hypertensive Patients with Type 2 Diabetes and Normal Ejection Fraction
...Show More Authors

View Publication
Crossref
Publication Date
Sat Oct 16 2021
Journal Name
Energies
Performance Analysis of a Solar Cooling System with Equal and Unequal Adsorption/Desorption Operating Time
...Show More Authors

In solar-thermal adsorption/desorption processes, it is not always possible to preserve equal operating times for the adsorption/desorption modes due to the fluctuating supply nature of the source which largely affects the system’s operating conditions. This paper seeks to examine the impact of adopting unequal adsorption/desorption times on the entire cooling performance of solar adsorption systems. A cooling system with silica gel–water as adsorbent-adsorbate pair has been built and tested under the climatic condition of Iraq. A mathematical model has been established to predict the system performance, and the results are successfully validated via the experimental findings. The results show that, the system can be operational

... Show More
View Publication
Scopus (11)
Crossref (12)
Scopus Clarivate Crossref